SITE PREPARATION
Plumbing
Installation must comply with all applicable plumbing codes.
The water supply line should be located within the shaded
area shown in the illustration below. The water supply line
should be connected to the house supply with an easily
accessible shut-off valve. Do not use self-piercing valves.
The water supply line must not interfere with installation of
the anti-tip brackets.
A reverse osmosis system can be used provided there is
constant water pressure of 35–120 psi
(2.4–8.3 bar) supplied
to the unit at all times. In this application, the water ltration
system must be bypassed by removing the lter. A copper
line is not recommended for this application.
PLUMBING REQUIREMENTS
Water Supply
1
/4" OD copper, braided
stainless steel or PEX tubing
Pressure 35–120 psi
(2.4–8.3 bar)
Excess Line for Connection 36" (914)
Preparation
Uncrate the unit and inspect for damage. Remove the wood
base and discard shipping bolts and brackets. Remove and
recycle packing materials. Do not discard the kickplate, anti-
tip brackets and hardware.
Completely retract the front leveling legs to allow the unit to
be moved into position. The front and rear leveling legs can
be adjusted from the front once the unit is in position.
Remove the drain pan from the base of the unit to avoid
damage, and allow for proper appliance dolly placement.
The grille assembly should be removed prior to moving the
unit. To remove, pull out on the bottom edge of the grille and
rotate upward. Loosen the back two grille mounting screws
and remove the front two grille mounting screws. Refer to
the illustrations below. With the grille held rmly, pull forward
to remove.
BACK GRILLE
SCREW
FRONT
GRILLE SCREW
Grille removal.
Grille mounting screws.
3" (76)
18" (457)
6" (152)
RIGHT SIDE
OF OPENING
AREA EXTENDS
1
/2" (13)
FORWARD ON FLOOR
Water supply location.