Technical Information
• NEMA ratings vs IP ratings
Whereas IP ratings only consider protection against ingress of foreign bodies (first digit) and ingress of water (second digit), NEMA ratings consider
these but also verify protection from external ice, corrosive materials, oil immersion, etc.
The correlation between NEMA & IP being limited only to dust and water, we can state that a NEMA type is equivalent to an IP rating but it is not
possible to say the contrary.
Below a list of some NEMA standards:
What is NEMA Rating ?
Enclosure
rating
IP20 IP22 IP55 IP64 IP65 IP66 IP67 IP68
Type 1
Type 3
Type 3R
Type 3S
Type 4
Type 4X
Type 6
Type 6P
Type 12
Type 13
• indicates compliance
6 IP67 Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental
contact with the enclosed equipment, falling dirt, hose-directed water, the entry of water during occasional temporary
submersion at a limited depth and damage from external ice formation.
6P IP68 Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental
contact with the enclosed equipment, falling dirt, hose-directed water, the entry of water during prolonged submersion at
a limited depth and damage from external ice formation.
Type 6 rating can be either Type 6 or Type 6P - please see below: