User guide
13-10
FlexPak 3000 DC Drive Software Reference
A00004
NETWORK
COMMUNICATION
TIMEOUT
Network communications is missing or failed to communicate with
master (
CONTROL
SOURCE
SELECT
set to
NETWORK
).
Possible causes:
•
NETW
CONNECT
TYPE
(P.910) was changed from
BASIC
to
FULL
.
•
NETW
DROP
NUMBER
(P.900) was changed.
•
Network option cable connections are loose or not connected.
•
Network option device failed or master communications failed.
A00005
INVERTING
FAULT
AVOIDED
The inverting fault avoidance logic has detected conditions that could
have caused an inverting fault. The drive took action to avoid an actual
inverting fault. See section 13.7, Setting Up Inverting Fault Avoidance, for
more information on this alarm.
A00006
CONTROL
NET
PROGRAM
MODE
The PLC communicating with the drive from ControlNet has entered
Program mode; drive operation is determined by
CNI
PROG
/
RUN
MODE
(P.915).
A00030
MAIN
CONTACTOR
DID
NOT
OPEN
The main (
FN
) contactor did not open following a stop. If a dynamic
braking kit is used, the dynamic braking auxiliary contact is wired in
series with the
FN
auxiliary contact.
Possible causes:
•
Disconnected, loosely connected, or damaged
FN
,
FN
auxiliary,
dynamic braking, or dynamic braking auxiliary wiring.
•
FN
,
FN
auxiliary, dynamic braking or dynamic braking auxiliary
contactor failure.
•
Disconnected, loosely connected, or damaged main contactor or
dynamic brake control wiring (
MCR
or
DBCR
).
A00031
MAIN
CONTACTOR
DID
NOT
CLOSE
The main (
FN
) contactor did not close following a run or jog command. If
a dynamic braking kit is used, the dynamic braking auxiliary contact is
wired in series with the
FN
auxiliary contact.
Possible causes:
•
Disconnected, loosely connected, or damaged
FN
,
FN
auxiliary,
dynamic braking or dynamic braking auxiliary wiring.
•
FN
,
FN
auxiliary, dynamic braking, or dynamic braking auxiliary
contactor failure.
•
Disconnected, loosely connected or damaged main contactor or
dynamic brake control wiring (
MCR
or
DBCR
).
•
If Dynamic Braking kit is not installed, missing jumper wire at terminals
3 and 4 on the field/DB terminal strip.
Table 13.2 – Alarm Codes (Continued)
Code Display Description