User guide

10-4
FlexPak 3000 DC Drive Software Reference
NETW
DROP
NUMBER
(P.900)
Network Drop
Number. Selects the
base drop number
the network option
board will respond to
on the network.
NETW
DROP
NUMBER
cannot be changed
through the network.
Parameter Range:
For AutoMax Network Communication kit:
1 to 55 if
NETW
CONNECT
TYPE
=
BASIC
;
1 to 52 if
NETW
CONNECT
TYPE
=
FULL
For DeviceNet Interface kit: 0 to 63 (
NETW
CONNECT
TYPE
value does not affect)
For ControlNet Network Communication kit: 1 to 99
(
NETW
CONNECT
TYPE
value does not affect)
Default Setting:
1
Parameter Type:
Configurable
OIM Menu Path(s):
Network Communications
When
NETW
CONNECT
TYPE
(P.910) is set to
FULL
, the AutoMax Network
Communication kit occupies multiple network drops beginning at
NETW
DROP
NUMBER
. The number of drops occupied (drop depth) affects the upper limit of
NETW
DROP
NUMBER
. See
NETW
CONNECT
TYPE
(P.910), to determine drop depth.
NETW
OUT
REG
1
SELECT
(P.902)
Selects the
parameter to be
monitored.
Parameter Range:
–32768 to 32767
Default Setting:
0
Parameter Type:
Tun abl e
OIM Menu Path(s):
Network Communications
Select the parameter to monitor by configuring the parameter number. For example,
setting this parameter equal to 588 will write the value of parameter
FIELD
DELTA
(P.588) to the installed network register.
NETW
OUT
REG
2
SELECT
(P.903)
Selects the
parameter to be
monitored.
Parameter Range:
–32768 to 32767
Default Setting:
0
Parameter Type:
Tun abl e
OIM Menu Path(s):
Network Communications
Select the parameter to monitor by configuring the parameter number. For example,
setting this parameter equal to 588 will write the value of parameter
FIELD
DELTA
(P.588) to the installed network register.