This product complies with Electromagnetic
Compatibility (EMC) Directive 89/336/EEC, when
the following requirements for a conforming
installation are applied:
D an input line filter must be installed to reduce
conducted emissions. Refer to the accessory
list in Appendix A.
D the controller system must be mounted in a
shielded enclosure to reduce radiated
emissions. A typical NEMA or IEC metal
enclosure is adequate.
D motor cables must be in conduit, or have
shielding/armor with equivalent attenuation to
reduce radiated emissions.
D motor cable lengths are as specified in table
2.A.
D control and signal wiring must be in conduit or
have shielding with equivalent attenuation.
#%' !
#''%"#$',,
(.'-#'!,+/,
(.'-#'!(+*.
$#!%
#'
%#'
$
&&
&0
-(&
%#
%
))'#0 (+-#%,('('-+(%%+#&',#(',
'/#!"-,
$%% % #
Take these actions to prolong controller life and
performance:
D store within an ambient temperature range of
-40_ to +85_ C
D store within a relative humidity range of 0%
to 95%, non–condensing
D protect the cooling fan by avoiding dust or
metallic particles
D avoid storing or operating the controller
where it could be exposed to a corrosive
atmosphere
D protect from moisture and direct sunlight
D operate at an ambient temperature range of
0_ to +50_ C
To maintain proper working conditions, install
the controller on a flat, vertical and level
surface. Use mounting screws up to 4.5mm
(0.177 inches) in diameter or mount on 35mm
DIN Rail.
Important: The conformity of this controller and
filter to any standard does not guarantee that the
entire installation will conform. Many factors can
influence the total installation and only direct
measurements can verify total conformity.
A copy of the Declaration of Conformity (DOC) is
available from your local Allen–Bradley sales
office.