9600 ® INTEGRATED COMFORT SOLUTIONS™ DIGITAL PROGRAMMABLE THERMOSTAT E G ELECTRIC GAS 5 - 2 Day Programmable 1 Heat / 1 Cool User’s Manual Quick Start Installation and Programming WA 110-653C RRANTY Installation Guide IMPORTANT SAFETY INFORMATION WARNING: • Always turn off power at the main power source by unscrewing fuse or switching circuit breaker to the off position before installing, removing, cleaning, or servicing thermostat.
Features • Four setpoints for weekday programming—two setpoints for weekend comfort. • Two AA ENERGIZER brand batteries retain program memory even during power outages. • Low battery indicator. • Fahrenheit/Celsius display option. • Programmable from 45°F (4°C) to 90°F (32°C). • Accuracy within ± 1 degree. • Adjustable temperature differential: 1-3 degrees. • Maintains summer and winter programming. • Low temperature freeze protection.
Figure 1 Installing Item 9600 Thermostat NOTE: FOR NEW INSTALLATIONS, MOUNT THERMOSTAT ON AN INSIDE WALL, 4-5 FEET DO NOT INSTALL BEHIND A DOOR, IN A CORNER, NEAR AIR VENTS, DIRECT SUNLIGHT, OR NEAR ANY HEAT OR STEAM GENERATING FIXTURES. INSTALLATION THESE PLACES WILL AFFECT THERMOSTAT OPERATION. ABOVE THE FLOOR. 1. Turn power off to the heating and cooling systems. 2. Place COOL-OFF-HEAT in OFF position. COOL-OFF-HEAT PROG > MAN > IN AT SET PROG/MAN COOL-OFF-HEAT AUTO - ON AUTO - ON 3.
Figure 3 MOUNTING HOLES AM PM PROG MORN DAY EVE NITE CHANGE SET RH RC MAN W Y AUTO/MAN G COOL OFF HEAT Elec Gas FAN AUTO ON 7. Drill the marked holes using a 3/16” drill bit. Note: Enclosed plastic anchors do not require a drilled hole for drywall. 8. Tap plastic anchors into the wall. 9. Align base with plastic anchors and feed wires through opening (see Figure 4). Figure 4 AM PM PROG RH RC MORN DAY EVE NITE CHANGE SET MAN W Y AUTO/MAN G COOL OFF HEAT Elec Gas FAN AUTO ON 10.
13. Install two AA ENERGIZER brand batteries or equivalent into battery compartment. Be sure to match positive (+) ends of batteries with positive (+) battery terminals in the battery compartment. The display will show as follows: 14. Replace cover on thermostat by snapping into place. 15. Turn on power to system. Test thermostat as described in the section To Test Thermostat. Programming Guide Set Time of Day, Day of Week, Temperature Differential 1. Press and hold SET. Press PROG/MAN.
> Press > 3. Press SET P to change temperature differential* *THE TEMPERATURE DIFFERENTIAL IS FACTORY PRESET AT 1°. THIS MEANS THAT WHENEVER THE ROOM TEMPERATURE CHANGES BY ONE FULL DEGREE FROM THE TEMPERATURE SETTING, THE SYSTEM WILL TURN ON. IF THE SYSTEM TURNS ON TOO OFTEN, INCREASE THE TEMPERATURE DIFFERENTIAL. Changing Fahrenheit (F) to Celsius (C) Press > SET P > Press and hold SET. Release both simultaneously. Setting Daily Programming 1. Place COOL-OFF-HEAT switch in COOL position.
4. Press SET. SET PR PROG COOL-OFF-HEAT AUTO - ON > SET PROG/MAN > > > MAN 5. Press or to change MORN temperature. 6. Repeat Steps 2-5 for DAY, EVE, and NITE. COOL-OFF-HEAT 7. Shift COOL-OFF-HEAT switch to HEAT position. 8. Repeat steps 2-6 to program HEAT (winter) settings. NOTE: BOTH SUMMER AND WINTER PROGRAMS USE THE SAME TIME SETTINGS. Your thermostat is now programmed for summer and winter operation.
Temporary Program Override To temporarily increase or decrease temperature: > > Press or : PROG > > MAN SET PROG/MAN COOL-OFF-HEAT AUTO - ON The thermostat will automatically return to the program at the next scheduled setting change. Manual Operation 1. Press PROG/MAN until indicator is in MAN position. PROG MAN > > T PROG/MAN SET PROG/MAN COOL-OFF-HEAT PROG AUTO - ON > 2. Press or to adjust temperature settings.
To Test Thermostat WARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS VALVE OR SYSTEM CONTROL TO TEST OPERATION. THIS WILL DAMAGE THE THERMOSTAT AND VOID YOUR WARRANTY. CAUTION: DO NOT SWITCH SYSTEM TO COOL IF THE TEMPERATURE IS BELOW 50°F (10°C). THIS CAN DAMAGE THE AIR CONDITIONING SYSTEM AND CAUSE PERSONAL INJURY. COOL-OFF-HEAT 1. Place the COOL-OFF-HEAT switch into the COOL position. 2. Press the button until the temperature setting is at least 3 degrees below the room temperature.
Troubleshooting Symptom Thermostat does not turn on system. Remedy Check wiring. (See INSTALLATION) Check fuse. Replace with 2 amp Slo-Blo fuse if fuse has opened. Thermostat turns on and off too frequently. Increase temperature differential. (See PROGRAMMING) Display is blank, flashing or constant LO BAT. Replace batteries. Weekend program follows four adjustment settings. Verify that day of week is set correctly. (See PROGRAMMING) System fan does not operate properly.
Wiring Diagrams The following is just a sample of the most common types of HVAC systems. Refer to your system’s installation manual for wiring information.
FIVE-YEAR LIMITED WARRANTY Maple Chase Company warrants to the original contractor installer or to the original consumer user, each new Robertshaw thermostat to be free from defects in materials and workmanship under normal use and service for a period of five (5) years from date of purchase.