Technical information

MM200 High-Speed Microwave Modem Appendix B
TM086Rev 4.1 B-11
radMM200TxInterfaceMajorAlarmMask INTEGER,
radMM200TxInterfaceMinorAlarmMask INTEGER,
radMM200TxInterfaceJitterControl INTEGER
}
radMM200TxInterfaceNVIndex OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index into the MM200 Tx interface on-volatile table."
::= { radMM200TxInterfaceNVStatusEntry 1 }
radMM200TxInterfacePID OBJECT-TYPE
SYNTAX INTEGER (0..8192)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the interface Program Id. If not in 188 byte
framing mode (unframed), this PID steers the packet to
the appropriate interface. In the MM200, only one
framed interface is allowed and its packets are sent in
the clear, without modifications. The Null PID and the PIDs
of the unframed interfaces should be unique. All packets
PIDs not equal to these will be sent to the framed
interface."
::= { radMM200TxInterfaceNVStatusEntry 2 }
radMM200TxInterfaceDataRate OBJECT-TYPE
SYNTAX INTEGER (64000..200000000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the data rate in BPS of the individual interfaces.
The data rate is T3, E3, or STS1 for G.703
155.52M BPS for OC3 and STM1
1.544M BPS for T1
2.048M BPS for E1
Variable for parallel and ASI
64K BPS for 8 channel DS0
The range is between 64K to 200M BPS"
::= { radMM200TxInterfaceNVStatusEntry 3 }
radMM200TxInterfaceControl OBJECT-TYPE
SYNTAX ControlType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls the Tx interface."
::= { radMM200TxInterfaceNVStatusEntry 4 }
radMM200TxInterfaceType OBJECT-TYPE
SYNTAX INTEGER {
asi(1)
aasi(2)
t3(3),
e3(4),
sts1(5),
t1(6),
e1(7),
ds0x8(8),
ds0x7A(9),
parallelDVB(10),
parallelM2P(11),
oc3(12),
stm1(13),
hssi(14),