DL8765 Specifications are subject to change without notice. © 2015 Koninklijke Philips N.V. All rights reserved Philips Consumer Lifestyle BV Tussendiepen 4, 9206AD Drachten, Netherlands Fax +31 (0)512594316 4222.100.4515.2 (10/2015) >75% recycled paper >75% papier recyclé 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2 1 1 - 2 cm 0.4" - 0.
1 1 2 3 4 15 14 5 13 6 7 12 8 9 11 10 16 17 English Introduction Congratulations on your purchase and welcome to Philips! To fully benefit from the support that Philips offers, register your product at www.philips.com/welcome.
Symbol for 'Including RF transmitter'. This means that this device emits non-ionizing radiation. All devices with RF transmitters or that use RF electromagnetic energy must have a label with this symbol. Indicates caution.The user should consult the instructions for use for important cau tionary information such as warnings and precautions that cannot, for a variety of reasons, be presented on the medical device itself. Symbol for micro-USB connector. Symbol for USB connector.
- - - - - - - - - - - - The effectiveness of this blood pressure moni tor has not been established in pregnant (including pre-eclamptic) women. Common arrhythmias (such as atrial or ventric ular premature beats or atrial fibrillation) and peripheral artery disease / arteriosclerosis can affect the performance (accuracy) of this blood pressure monitor. Please consult your doctor how to best use this blood pressure monitor if you suffer from any of these conditions.
Sym bol Description Explanation Diastolic blood pres sure Minimum blood pressure, also see section Systolic and diastolic pressure. Heart rate Number of heartbeats per minute (pulse is typically equivalent to heart rate). Battery sta tus Indicates status of battery during charging. Measure ment unit Measurement unit of blood pressure. Inflation indicator The cuff is inflating. Deflation indicator The cuff is deflating.
device. This system follows the classification sys tem of the World Health Organisation (WHO).
- For a meaningful comparison, try to measure under similar conditions. For example, take dai ly measurements at approximately the same time, on the same arm, or as directed by your doctor. - For a good Bluetooth connection between the blood pressure monitor and your mobile device, make sure the two are in close distance and there are no obstacles between the two devices. We recommend not to have the two devices further than 5 meters apart.
- If the data transmission is successful, the mea surement results are displayed in the health app. If the data transmission fails, 'the Bluetooth symbol together with 'Err' is shown. The pend ing measurement data will be transmitted to your mobile device the next time it connects with your blood pressure monitor. You can also try to resend the data: - Activate the Health app on your mobile device. - Press the user ID button or 'on' button to switch on the blood pressure monitor.
Problem Possible cause Solution You are using The variations in medication. blood pressure can be greater if you are using medica tion. My blood pressure measure ment from the hospital is different from the measure ment at home. You per formed multi ple measure ments direct ly after each other. Wait at least 3 minutes between measurements. This allows your blood circulation to recover. Multiple vari ables may affect your blood pres sure such as the weath er, emotions and exercise.
Specifications Power supply 3.7V 420mAH built-in rechargeable li-polymer battery Display Display with white back light Visible area = 46.8mm (L) x29.3mm (W) Measurement method Oscillometric method Measurement range Rated cuff pressure: 0kPa-40kPa (0mmHg-300mmHg) Measurement pressure: 4kPa-34kPa (40mmHg-230mmHg) heart rate: 40-199 beats per minute Accuracy Pressure: 5°C-40°C with in ±0.
or the user of the device should assure that it is used in such an environment. Immu IEC nity test 60601 test level Com Electromagnetic pliance environment level guidance Electro ±6 kV contact static dis ±8 kV air charge (ESD) IEC 61000- 4-2 ±6 kV contact Electri cal fast tran sient/b urst IEC 61000- 4-4 ±2 kV for power supply lines Mains power qual ity should be that of a typical com mercial or hospital environment.
NOTE 1 At 80 MHz and 800 MHz, the higher fre quency range applies. NOTE 2 These guidelines may not apply in all situ ations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. (a) Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) tele phones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy.