FCC Part 15.247 Transmitter Certification Frequency Hopping Spread Spectrum Transmitter Test Report FCC ID: P2SNTGSRFE01 FCC Rule Part: 15.247 ACS Report Number: 05-0356-15C Manufacturer: Neptune Technology Group, Inc. Model: R900E Users Manual 5015 B.U.
FOCUS kWh Solid-State Meter Technical Manual Bulletin 160 Revision 2.
Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose without the express written permission of Landis+Gyr, Inc.. 2003 Landis+Gyr, Inc. All rights reserved. For further information, contact: Landis+Gyr, Inc. Meter Division 2800 Duncan Road Lafayette, IN 47904-5012 USA Tel.
TABLE OF CONTENTS PURPOSE .......................................................................................................................... VI TARGET GROUP .................................................................................................................. VI CONDITIONS...................................................................................................................... VI SAFETY WARNINGS .................................................................................
4.1.4. 5. K-BASE ............................................................................................................... 11 OVERVIEW OF ELECTRONIC HARDWARE .......................................................................... 12 5.1.1. LCD DISPLAY ....................................................................................................... 12 5.1.2. DISPLAY SCROLL SEQUENCE: ................................................................................... 12 5.1.3.
STARTING LOAD ................................................................................................................ 21 FORMS ............................................................................................................................ 21 OPERATING TEMPERATURE .................................................................................................. 21 ACCURACY CLASS .............................................................................................................
FIGURE 19 – CALIBRATION LED LOCATION ............................................................................ 16 FIGURE 20 – SUGGESTED KYZ OUTPUT CONNECTION .............................................................. 18 FIGURE 21 - KYZ BOARD/CABLE, MOUNTING SCREW AND SPACER .............................................. 19 FIGURE 22 - FOCUS MOTHER BOARD 10-PIN HEADER ............................................................. 19 FIGURE 23 - FOCUS KYZ INSTALLED ONTO MOTHERBOARD .....................
Purpose This technical manual contains the following information: • Installation instructions, construction, characteristics and maintenance information • Performance and technical data Target Group The contents of this technical manual are intended for technically qualified personnel of energy supply companies responsible for the system planning, installation, commissioning, operation, maintenance, decommissioning and disposal of the meters.
! Warning The use of I/O cables in ungrounded services could cause serious personal injury, property damage, and/or death The FOCUS does not have an auto-ranging power supply. Care should be taken to ensure that meters are installed correctly, matching meter form and voltage with the installation. Published Specifications The Focus kWh is designed in accordance with the specifications listed below.
Cet appareillage numérique de la classe B répond à toutes les exigences de l'interférence canadienne causant des règlements d'équipement. L'opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l'interférence nocive, et (2) ce dispositif doit accepter n'importe quelle interférence reçue, y compris l'interférence qui peut causer l'opération peu désirée. FCC Information: This device complies with part 15 of the FCC rules.
1. Introduction To The FOCUS The FOCUS meter was designed to be a low-cost, solid-state, kWh-only meter as an alternative metering and AMR platform to the induction meter. The meter is based on reliable, field proven digital multiplication measurement technique. The meter platform will measure energy accurately over varying environmental conditions. It is designed to be stable over its long expected life. A diagram of basic operation is noted below.
Figure 3 - Meter Assembly Exploded View The Focus meter is composed of three basic sub-assemblies: The baseplate assembly, the electronics housing assembly and the meter cover. The electronics housing assembly snaps onto the baseplate and creates a weatherproof seal when the cover is installed. The standard cover includes an emboss to align an optical probe for register configuration purposes.
Electronic Housing Assembly Figure 5 - Electronics Housing Assembly Exploded View The Electronics Housing contains the measurement board and any optional electronics assemblies such as option boards or communication devices. It also contains the liquid crystal display (LCD) on which meter readings and other pertinent data can be displayed. The Electronics Housing assembly snaps onto the baseplate and can be removed and reinstalled many times without damage to the meter.
2. The FOCUS Meter Family The FOCUS provides more than just reliability and accurate billing data. The FOCUS is designed to be a building block for a complete metering system. Each FOCUS has built-in compatibility for a variety of AMR packages. Any of these can be factory installed. Some can be added to the meter dependent upon the meter vintage and respective AMR technology. Register Types The Focus kWh is an active energy “kWh-only” meter.
3. Meter Assembly Removal of the Electronics Housing from the Baseplate In rare instances, it may be necessary to access the inner electronics of the Focus meter. To remove the Electronics Housing from the baseplate, set meter on a solid surface and place hands around the bottom of the gray housing where it meets with the baseplate.
Figure 8 – Unused T-Seals Figure 9 – Formed T-Seal After Installation Figure 10 – T-Seal Installed Each T-seal is installed by fully inserting it through the cover and through the baseplate assembly. Bend the T-seal tab to prevent extraction. Next, bend the T-seal over so that it resides within the baseplate assembly pocket. Finally, bend the top of the T-seal over so that it is flush against the cover.
4. Application Information Available Meter Forms The FOCUS is available in the following meter forms: 4.1.1. S-Base • Transformer rated: Class 10 & 20: 3S, 4S • Self-contained: class 100: 1S • Self-contained: class 200: 2S, 12S and 25S (Network) • Self-contained: class 320: 2SE 4.1.2. • K-Base Self-contained: class 480: 2K Meter Form Schematic Diagrams Self-contained meter forms Figure 11 – Form 1S Table 1 - Form 1S Specification Form 1S Class 100 Test Amps 15 Volts 120 7 Wire 2 Kh 1.
Figure 12 – Form 2S, 2SE Table 2 - Form 2S/2SE Specifications Form 2S 2S 2SE 2SE Class 200 200 320 320 Test Amps 30 50 50 30 Volts 240 240 240 240 Wire 3 3 3 3 Kh 7.2 7.2 12 12 Figure 13 – Form 12S (Network) – Form 25S (Network) Form 12S 25S Class 200 200 Test Amps 30 30 Volts 120/208 120/208 8 Wire 3 3 Kh 14.4 14.
Figure 13 – Form 2K Table 3 - Form 2K Specifications Form 2K 2K Class 480 480 Test Amps 30 50 Volts 240 240 Wire 3 3 Kh 14.4 14.4 Wire 2 2 2 2 Kh .3 .3 .6 .6 Transformer Rated Meter Forms Figure 14 – Form 3S Table 4 - Form 3S Specifications Form 3S 3S 3S 3S Class 10 20 10 20 Test Amps 2.5 2.5 2.5 2.
Figure 15 – Form 4S Table 5 - Form 4S Specifications Form 4S 4S Class 10 20 Test Amps 2.5 2.5 Volts 240 240 Wire 3 3 Kh .6 .6 The form 3S features a movable fifth terminal that can be located in the 3 o’clock or 6 o’clock centered locations. Forms 12S and 25S (Network) feature a movable fifth terminal that can be located in the 3 o’clock, 6 o’clock centered, or 6 o’clock offset locations. Installation Procedures 1).
4.1.3. Socket base 1). Compare wiring with diagrams of Section 3.2 to make sure the meter is wired properly. 2). Plug meter terminal blades into socket to make a connection with the terminal jaws. 3). Apply load. 4). Check to make sure that the LCD operates and sequences through the display items which were programmed into the meter. 4.1.4. K-Base 1). Compare the wiring with diagrams of Section 3.2 to made sure the meter is wired properly. Install bypasses (if change-out). 2).
5. Overview of Electronic Hardware 5.1.1. LCD Display Figure 16 – Liquid Crystal Display The kWh FOCUS LCD shows the digital power indicator, nominal service voltage and various selectable metrics. 5.1.2. Display Scroll Sequence: The display scroll sequence is programmable at the factory or by the user with Focus Configuration Tool. The scroll sequence can consist of up to 16 individual displays.
When internal meter errors occur, error codes will be added to the end of the scroll sequence. The segment check display does not affect the DPI. This permits a user to use the DPI for timing when a segment check is being displayed during a scroll sequence. A two character programmable alphanumeric label can be associated with each display. This twocharacter field is used to identify the value displayed. It can be left blank if desired. 5.1.3.
Diagnostics/Error Codes 5.1.6. Meter Errors The following table contains the meter errors available for display in the diagnostic status word.
6. Configuring the Meter 6.1.1. Configuration Port The ability to configure the meter is provided through a secure meter configuration port. A cover mounted optical configuration port accommodates meter configuration by the user. The configuration port is designed to be used in a meter shop environment, (room temperature/ambient lighting conditions). The configuration port interface supports a read/write security function.
7. Meter Calibration 7.1.1. Calibration LED The Focus kWh has an infrared light emitting diode (LED) that emits energy pulses. The calibration LED is deactivated 24 hours after the meter powers up. Once reactivated (recycle power), the calibration LED remains active for 24 hours. The calibration LED is accessible from the front of the meter cover. The user can fix an LED pickup device to the front of the meter.
7.1.2. Factory Calibration The meter is calibrated at the factory as part of the manufacturing process. Calibration constants are stored in nonvolatile memory. These constants are not alterable once programmed except through another calibration cycle at the factory. Sufficient security features are provided to prevent the user from altering the calibration constants stored within the meter. 7.1.3. Customer Calibration Adjustment Focus kWh calibration is adjustable.
9. Pulse Outputs The Focus kWh offers three internal solid-state pulse initiator outputs. Refer to Landis+Gyr Focus kWh Pulse Outputs Application Note (Doc. No. 04061-0) for detailed description of Pulse Outputs Functionality. 9.1.1. Relay #1 Output (KYZ only) KYZ is available as an option to the FOCUS meter. The option board can be assembled in the meter at the time of order or can be meter shop retrofitted. kWh FOCUS Options One Relay: Programmable for KYZ.
In the kWh FOCUS, pulse initiator signals are provided by Relay 1. The KYZ output value can be any one of the three choices listed in Table 10 below: Metric Choices Select any one 1). +kWh 2). –kWh 3).
9.1.2. Communications (Pulse Initiator 1 and 2) Focus kWh provides two scalable TTL-level pulse outputs for interfacing with pulse accumulating AMR modules. Each output is user configurable to function in one of two operating modes: 1) Quadrature Pulse and 2) Differential +kWh Pulse. These are used only for configuration of factory installed or field retrofitted AMR modules (under glass).
10. Product Specifications General Specifications • Active Energy “kWh-Only” meter • Digital Multiplication Measurement Technique • Non-Volatile Memory • Designed for 15+ year life Power Consumption • Digital Power Indicator (DPI) Burden • Burden < 1.8 Watts Starting Load • Starting Load 50 mA or 12 Watts Forms • Meter forms 1S, 2S, 2SE, 2K, 3S, 4S, 12S, 25S Operating Temperature • Operating Temperature -40º to 85ºC Accuracy Class • Load Performance Accuracy Class .