Operation and Parts Manual ® Whisperwatt™ Series MODEL dca70USI3CAN 60hz generator (isuzu BJ4JJ1-XYGD-02 DIESEL ENGINE) PARTS LIST NO. M2870400304C m2874400004 Revision #1 (09/24/13) To find the latest revision of this publication, visit our website at: www.multiquip.com THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
Fuel and chemical warning Diesel engine exhaust and some of its constituents are know to cause cancer, birth defects and other reproductive harm. page 2 — DCA70USI3can 60 hz Generator • operation and parts manual — rev.
Reporting Safety Defects If you believe that your vehicle has a defect that could cause a crash or could cause injury or death, you should immediately inform the National Highway Traffic Safety Administration (NHTSA) in addition to notifying Multiquip at 1-800-421-1244. If NHTSA receives similar complaints, it may open an investigation, and if it finds that a safety defect exists in a group of vehicles, it may order a recall and remedy campaign.
Table of Contents DCA70USI3CAN Generator Fuel and Chemical Warnings.................................... 2 Reporting Safety Defects.......................................... 3 Table Of Contents..................................................... 4 Parts Ordering Procedures....................................... 5 Safety Information............................................... 6-11 Specifications......................................................... 12 Dimensions.......................................
www.multiquip.com Parts Ordering Procedures Ordering parts has never been easier! Choose from three easy options: Order via Internet (Dealers Only): Best Deal! Effective: January 1st, 2006 If you have an MQ Account, to obtain a Username and Password, E-mail us at: parts@multiquip. com. Order parts on-line using Multiquip’s SmartEquip website! ■ View Parts Diagrams ■ Order Parts ■ Print Specification Information To obtain an MQ Account, contact your District Sales Manager for more information.
Safety Information Do not operate or service the equipment before reading the entire manual. Safety precautions should be followed at all times when operating this equipment. Failure to read and understand the safety messages and operating instructions could result in injury to yourself and others. Potential hazards associated with the operation of this equipment will be referenced with hazard symbols which may appear throughout this manual in conjunction with safety messages.
Safety Information general SaFetY CAUTION never operate this equipment without proper protective clothing, shatterproof glasses, respiratory protection, hearing protection, steel-toed boots and other protective devices required by the job or city and state regulations. never operate this equipment when not feeling well due to fatigue, illness or when under medication. never operate this equipment under the influence of drugs or alcohol.
Safety Information ENGINE SAFETY DANGER The engine fuel exhaust gases contain poisonous carbon monoxide. This gas is colorless and odorless, and can cause death if inhaled. The engine of this equipment requires an adequate free flow of cooling air. never operate this equipment in any enclosed or narrow area where free flow of the air is restricted. If the air flow is restricted it will cause injury to people and property and serious damage to the equipment or engine.
Safety Information FUel SaFetY DANGER DO NOT start the engine near spilled fuel or combustible fluids. Diesel fuel is extremely flammable and its vapors can cause an explosion if ignited. Make sure the hitch and coupling of the towing vehicle are rated equal to, or greater than the trailer “gross vehicle weight rating.” alWaYS inspect the hitch and coupling for wear. never tow a trailer with defective hitches, couplings, chains, etc.
Safety Information eleCtrICal SaFetY DANGER DO NOT touch output terminals during operation. Contact with output terminals during operation can cause electrocution, electrical shock or burn. The electrical voltage required to operate the generator can cause severe injury or even death through physical contact with live circuits. Turn generator and all circuit breakers OFF before performing maintenance on the generator or making contact with output terminals.
Safety Information If the battery liquid (dilute sulfuric acid) comes into contact with clothing or skin, rinse skin or clothing immediately with plenty of water. emISSIonS InFormatIon If the battery liquid (dilute sulfuric acid) comes into contact with eyes, rinse eyes immediately with plenty of water and contact the nearest doctor or hospital to seek medical attention.
Specifications Model Type Armature Connection Phase Standby Output Prime Output Voltage Frequency Speed Power Factor Aux. AC Power Voltage Output Weight (No Fuel) Weight (Fuel) Maximum Lifting Capacity Model Type No. of Cylinders Bore x Stroke Displacement Rated Output Starting Coolant Capacity Lube Oil Capacity Fuel Type Fuel Tank Capacity Fuel Consumption Battery Table 1.
Dimensions Figure 1. Dimensions Table 3. Dimensions Reference Letter Dimension in. (mm) Reference Letter Dimension in. (mm) A 30.10 in. (790 mm.) F 105.1 in. (2,670 mm.) B 30.20 in. (766 mm.) G 68.30 in. (1,735 mm.) C 30.20 in. (766 mm.) H 37.40 in. (950 mm.) D 30.20 in. (766 mm.) E 30.20 in. (766 mm.) DCA70USI3can 60 hz Generator • operation and parts manual — rev.
Installation Figure 2. Typical Generator Grounding Application page 14 — DCA70USI3can 60 hz Generator • operation and parts manual — rev.
Installation Outdoor Installation Generator Grounding Install the generator in a area that is free of debris, bystanders, and overhead obstructions. Make sure the generator is on secure level ground so that it cannot slide or shift around. Also install the generator in a manner so that the exhaust will not be discharged in the direction of nearby homes. To guard against electrical shock and possible damage to the equipment, it is important to provide a good EARTH ground.
General Information Generator Open Delta Excitation System This generator (Figure 3) is a high quality portable (requires a trailer for transport) power source for telecom sites, lighting facilities, power tools, submersible pumps and other industrial and construction machinery. This generator is equipped with the state of the art “OpenDelta” excitation system. The open delta system consist of an electrically independent winding wound among stationary windings of the AC output section.
Major Components Table 4. Generator Major Components ITEM NO. DESCRIPTION 1 Muffler Assembly 2 Engine Assembly 3 Enclosure Assembly 4 Generator Assembly 5 Output Terminal Assembly 6 Battery Assembly 7 Fuel Tank Assembly 8 Generator Control Panel Assembly 9 Engine Operating Panel Assembly Figure 3. Major Components DCA70USI3can 60 hz Generator • operation and parts manual — rev.
Generator Control Panel 1 7 DECREASE INCREASE 2 V U AUTO 6 MANUAL OFF/RESET W OFF 3 V-W LOW OIL PRESSURE HIGH COOLANT TEMPERATURE OVERCRANK OVERSPEED ENGINE RUNNING W-U U-V OFF 5 MOOOOO-20001Q 1000 4 2000 0 3000 RPM Figure 4. Generator Control Panel The definitions below describe the controls and functions of the Generator Control Panel (Figure 4). 1. Voltage Regulator Control — Allows ±15% manual adjustment of the generator’s output voltage. 2.
Notes DCA70USI3can 60 hz Generator • operation and parts manual — rev.
ENGINE OPERATING PANEL 1 3 8 2 9 DECREASE INCREASE 4 10 V 12 U 5 AUTO W OFF MANUAL OFF/RESET V-W LOW OIL PRESSURE HIGH COOLANT TEMPERATURE OVERCRANK OVERSPEED ENGINE RUNNING W-U U-V 6 OFF MOOOOO-20001Q 1000 2000 7 0 11 3000 RPM Figure 5. Engine Operating Panel page 20 — DCA70USI3can 60 hz Generator • operation and parts manual — rev.
ENGINE OPERATING PANEL The definitions below describe the controls and functions of the Engine Operating Panel (Figure 5). 1. Panel Light — Normally used in dark areas or at night time. When activated, panel lights will illuminate. When the generator is not in use be sure to turn the panel light switch to the OFF position. 2. Panel Light Switch — When activated will turn on control panel light. 3. Oil Pressure Gauge — During normal operation this gauge should read between 42 ~71 psi. (290~490 kPa).
OUTPUT TERMINAL PANEL FAMILIARIZATION Output Terminal Panel Output Terminal Familiarization The Output Terminal Panel (Figure 6) shown below is located on the right-hand side (left from control panel) of the generator. Lift up on the cover to gain access to receptacles and terminal lugs.
OUTPUT TERMINAL PANEL FAMILIARIZATION 120 VAC GFCI Receptacles There are two 120 VAC, 20 amp GFCI (Duplex Nema 5-20R) receptacles provided on the output terminal panel. These receptacles can be accessed in any voltage selector switch position. Each receptacle is protected by a 20 amp circuit breaker. These breakers are located directly above the GFCI receptacles. Remember the load output (current) of both GFCI receptacles is dependent on the load requirements of the U, V, and W output terminal lugs.
OUTPUT TERMINAL PANEL FAMILIARIZATION Connecting Loads Over Current Relay Loads can be connected to the generator by the Output Terminal Lugs or the convenience receptacles (Figure 11). Make sure to read the operation manual before attempting to connect a load to the generator. An over current relay (Figure 12) is connected to the main circuit breaker. In the event of an overload, both the circuit breaker and the over current relay may trip.
Load Application Single Phase Load Three Phase Load Always be sure to check the nameplate on the generator and equipment to insure the wattage, amperage, frequency, and voltage requirements are satisfactorily supplied by the generator for operating the equipment. When calculating the power requirements for 3-phase power use the following equation: Generally, the wattage listed on the nameplate of the equipment is its rated output.
GENERATOR OUTPUTS Generator Output Voltages Generator Amperage A wide range of voltages are available to supply voltage for many different applications. Voltages are selected by using the voltage selector switch (Figure 13). To obtain some of the voltages as listed in Table 7 (see below) will require a fine adjustment using the voltage regulator (VR) control knob located on the control panel. Table 8 shows the maximum amps the generator can provide. DO NOT exceed the maximum amps as listed.. Table 8.
GENERATOR OUTPUTS/gauge reading How to Read the ac ammeter and ac voltage gauges The AC ammeter and AC voltmeter gauges are controlled by the AC ammeter and AC voltmeter change-over switches. Both of these switches are located on the control panel and DO NOT effect the generator output. They are provided to help observe how much power is being supplied, produced at the UVWO terminals lugs.
OUTPUT TERMINAL PANEL CONNECTIONS UVWO Terminal Output Voltages Various output voltages can be obtained using the UVWO output terminal lugs. The voltages at the terminals are dependent on the position of the Voltage Selector Switch and the adjustment of the Voltage Regulator Control Knob. Remember the voltage selector switch determines the range of the output voltage. The voltage regulator (VR) allows the user to increase or decrease the selected voltage. 3Ø-240/139 UVWO Terminal Output Voltages 1.
OUTPUT TERMINAL PANEL CONNECTIONS 3Ø-480/277V UVWO Terminal Output Voltages 1Ø-240/120V UVWO Terminal Output Voltages 1. Place the voltage selector switch in the 3Ø 480/277 position as shown in Figure 24. 1. Place the voltage selector switch in the 1Ø 240/120 position as shown in Figure 26. Figure 24. Voltage Selector Switch 3Ø-480/277V Position Figure 26. Voltage Selector Switch 1Ø-240/120V Position 2. Connect the load wires to the UVWO terminals as shown in Figure 25. 2.
inspection/SETUP Circuit Breakers To protect the generator from an overload, a 3-pole, 175 amp, main circuit breaker is provided to protect the U,V, and W Output Terminals from overload. In addition two single-pole, 20 amp GFCI circuit breakers are provided to protect the GFCI receptacles from overload. Three 50 amp load circuit breakers have also been provided to protect the auxiliary receptacles from overload. Make sure to switch ALL circuit breakers to the OFF position prior to starting the engine.
inspection/SETUP Refueling Procedure: WARNING 2. Open cabinet doors on the “right side” of the generator (from generator control panel position). Remove fuel cap and fill tank (Figure 31). Diesel fuel and its vapors are dangerous to your health and the surrounding environment. Avoid skin contact and/or inhaling fumes. 1. Level Tanks — Make sure fuel cells are level with the ground. Failure to do so will cause fuel to spill from the tank before reaching full capacity (Figure 30).
inspection/SETUP Coolant (Antifreeze/Summer Coolant/ Water) ISUZU recommends ISUZU antifreeze/summer coolant for use in their engines, which can be purchased in concentrate (and mixed with 50% demineralized water) or pre-diluted. See the ISUZU Engine Owner’s Manual for further details. Cleaning the Radiator The engine may overheat if the radiator fins become overloaded with dust or debris. Periodically clean the radiator fins with compressed air.
inspection/SETUP Battery When connecting battery do the following: This unit is of negative ground DO NOT connect in reverse. Always maintain battery fluid level between the specified marks. Battery life will be shortened, if the fluid level are not properly maintained. Add only distilled water when replenishment is necessary. 1. NEVER connect the battery cables to the battery terminals when the MPEC Control Switch is in either the MANUAL position.
GENERATOR START-UP PROCEDURE Before Starting Starting CAUTION The engine’s exhaust contains harmful emissions. ALWAYS have adequate ventilation when operating. Direct exhaust away from nearby personnel. 1. Place the voltage selector switch in the desired voltage position (Figure 38). WARNING NEVER manually start the engine with the main, GFCI or auxiliary circuit breakers in the ON (closed) position. 1. Place the main, G.F.C.I., and aux.
GENERATOR START-UP PROCEDURE the problem. If the engine is running smoothly, place the engine speed switch (Figure 42) in the HIGH (up) position. 9. The ammeter (Figure 47) will indicate zero amps with no load applied. When a load is applied, the ammeter will indicate the amount of current that the load is drawing from the generator. Figure 42. Engine Speed Switch (High) 5. Verify that the engine running status LED on the MPEC module (Figure 43) is lit (ON) after the engine has started. Figure 47.
GENERATOR SHUT-DOWN PROCEDURES 13. Place the main, GFCI, and aux. circuit breakers in the ON position (Figure 51). 2. Place the engine speed switch (Figure 54) in the “LOW” (down) position.. Figure 54. Engine Speed Switch (Low) 3. Let the engine cool by running it at low speed for 3-5 minutes with no load applied. Figure 51. Main, Aux. and GFCI Circuit Breakers (ON) 4. Place the MPEC Control Switch (Figure 55) to the OFF/RESET position. 14.
Maintenance 10 Hrs DAILY X X X X X X Table 14.
Maintenance If the engine is operating in very dusty or dry grass conditions, a clogged air cleaner will result. This can lead to a loss of power, excessive carbon buildup in the combustion chamber and high fuel consumption. Change air cleaner more frequently if these conditions exists. Fuel Addition Add diesel fuel (the grade may vary according to season and locations). Removing Water from the Fuel Tank After prolonged use, water and other impurities accumulate in the bottom of the tank.
Maintenance Check Oil Level Radiator Cleaning Check the crankcase oil level prior to each use, or when the fuel tank is filled. Insufficient oil may cause severe damage to the engine. Make sure the generator is level. The oil level must be between the two notches on the dipstick as shown in Figure 28. The radiator (Figure 58) should be sprayed (cleaned) with a high pressure washer when excessive amounts of dirt and debris have accumulated on the cooling fins or tube.
Trailer Maintenance Trailer Maintenance This section is intended to provide the user with generic trailer service and maintenance information. The service and maintenance guidelines referenced in this section refer to a wide range of trailers. Remember periodic inspection of the trailer will ensure safe towing of the generator and will prevent personal injury and damage to the equipment. The definitions below describe some of the major components of a typical trailer that would be used with generator. 1.
Trailer Maintenance Brakes Hydraulic Surge Brakes Trailer brakes should be inspected the first 200 miles of operation. This will allow the brake shoes and drums to seat properly. After the first 200 mile interval, inspect the brakes every 3,000 miles. If driving over rough terrain, inspect the brakes more frequently. Figure 59 displays the major hydraulic surge brake components that will require inspection and maintenance.
Trailer Maintenance Tires/Wheels/Lug Nuts Suspension Tires and wheels are a very important and critical components of the trailer. When specifying or replacing the trailer wheels it is important the wheels, tires, and axle are properly matched. The leaf suspension springs and associated components (Figure 60) should be visually inspected every 6,000 miles for signs of excessive wear, elongation of bolt holes, and loosening of fasteners. Replace all damaged parts (suspension) immediately.
Trailer Maintenance Lug Nut Torque Requirements It is extremely important to apply and maintain proper wheel mounting torque on the trailer. Be sure to use only the fasteners matched to the cone angle of the wheel. Proper procedure for attachment of the wheels is as follows: 1. Start all wheel lug nuts by hand. 2. Torque all lug nuts in sequence (see Figure 61). DO NOT torque the wheel lug nuts all the way down. Tighten each lug nut in 3 separate passes as defined by Table 18. 3.
Trailer Wiring Diagram Figure 62. Trailer/Towing Vehicle Wiring Diagram page 44 — DCA70USI3can 60 hz Generator • operation and parts manual — rev.
Generator Wiring Diagram Figure 63. Generator Wiring Diagram DCA70USI3can 60 hz Generator • operation and parts manual — rev.
Engine Wiring Diagram Figure 64. Engine Wiring Diagram page 46 — DCA70USI3can 60 hz Generator • operation and parts manual — rev.
controller Wiring Diagram Figure 65. Engine Controller DCA70USI3can 60 hz Generator • operation and parts manual — rev.
Troubleshooting (Generator) Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, use Table 19 shown below for diagnosis of the Generator. If the problem cannot be remedied, consult our company’s business office or service plant. Symptom No Voltage Output Low Voltage Output High Voltage Output Circuit Breaker Tripped Table 19.
Troubleshooting (Diagnostic lamp) The engine controller of this generator diagnoses problems that arise from the engine control system and the engine itself. Press the diagnostic button (Figure 66) on the diagnostic panel to determine if an engine malfunction has occurred. Figure 66. Diagnostic Panel Method of Operation 1. Normally, the diagnostic lamp will be dimly lit when the MPEC Control Switch is placed in the MANUAL position. 2.
Explanation of Code in Remarks Column The following section explains the different symbols and remarks used in the Parts section of this manual. Use the help numbers found on the back page of the manual if there are any questions. NOTICE The contents and part numbers listed in the parts section are subject to change without notice. Multiquip does not guarantee the availability of the parts listed. Sample partS liSt NO. 1 2% 2% 3 4 part NO. part Name QtY. remarKS 12345 BOLT......................1 .....
Suggested Spare Parts dcA70USI3CAN WHISPERWATT GENERATOR with ISUZU BJ-4JJ1XYGD-02 DIESEL engine 1 to 3 units Qty. P/N Description 5............8980188580...........CARTRIDGE , OIL FILTER 5............8981430410...........FILTER, FUEL, ELEMENT, MAIN 5............8980758551...........FILTER, FUEL, ELEMENT, PRE 5............8980742880...........FILTER, FUEL, ELEMENT 5............8980714010...........FILTER, FUEL, FEED PUMP 3............0602046365...........ELEMENT, AIR 1............8980388560...........
GENERATOR ASSY. 3 2 1-12 1 - 9B 1 - 9A 1-9 1-11 1-10 14 13 16 17 18 7 6 23 9 23A 23B 12 21 20 21 page 52 — DCA70USI3can 60 hz Generator • operation and parts manual — rev.
GENERATOR ASSY. NO. PART NO.
control box ASSY. page 54 — DCA70USI3can 60 hz Generator • operation and parts manual — rev.
control box ASSY. NO. 1 1-1 1-2 1-3 1-4 1-5 2 2-1 3 4 5 6 7 8 9 10 11 12 12A 13 14 15 15A 16 17 17A 17B 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 PART NO.
control box ASSY. page 56 — DCA70USI3can 60 hz Generator • operation and parts manual — rev.
control box ASSY. NO. 35 36 37 38 39 40 41 41A 41B 42 42-1 43 44 44A 45 45A 46 47 48 49 49-1 49-2 49-3 50 51 51A 52 53 54 55 56 57 58 59 60 61 61A 62 63 63A 64 65 66 67 PART NO.
control box ASSY. page 58 — DCA70USI3can 60 hz Generator • operation and parts manual — rev.
control box ASSY. NO. 68 69 70 71 72 73 74 75 76 77 78 79 80 80A 81 82 83 84 85 PART NO.
ENGINE AND RADIATOR ASSY. 1A 46 47 30A 17B 17A 4 5 6 68 71 69 70 page 60 — DCA70USI3can 60 hz Generator • operation and parts manual — rev.
ENGINE AND RADIATOR ASSY. NO. 1 1A 1-1 2 3 4 5 6 7 7-1 8 9 10 11 12 13 14 15 16 17 17A 17B 18 19 20 21 22 23 24 25 26 27 28 29 30 30A 31 32 33 34 35 36 37 38 39 40 PART NO.
ENGINE AND RADIATOR ASSY. (continued) 1A 46 47 30A 17B 17A 4 5 6 68 71 69 70 page 62 — DCA70USI3can 60 hz Generator • operation and parts manual — rev.
ENGINE AND RADIATOR ASSY. (continued) NO. 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 PART NO.
OUTPUT TERMINAL ASSY. 11 11B 11A 12A 12 4 6 56 54 28A 28A 28 39 39A 28 ADD THE FOLLOWING DIGITS AFTER THE PART NUMBER WHEN ORDERING ANY PAINTED PANEL TO INDICATE COLOR OF UNIT: 1-ORANGE 5-BLACK 2-WHITE 6-CATERPILLAR YELLOW 3-SPECTRUM GREY 7-CATO GOLD 4-SUNBELT GREEN 8-RED THE SERIAL NUMBER MAY BE REQUIRED. page 64 — DCA70USI3can 60 hz Generator • operation and parts manual — rev.
OUTPUT TERMINAL ASSY. NO. 1 2 3 4 5 6 7 8 9 10 11 11A 11B 12 12A 13 14 15 16 17 18 19 20 21 22 23 24 24-1 25 26 27 28 28A 29 30 31 32 33 34 35 36 37 38 39 39A PART NO.
BATTERY ASSY. page 66 — DCA70USI3can 60 hz Generator • operation and parts manual — rev.
BATTERY ASSY. NO. PART NO. 1 0602220199 2 M9310500014 3 M9103000304 4 0602220920 5 M2346900504 6 M2346900604 7 8 0017112025 8A 0040512000 9 0016908025 9A 0040508000 PART NAME QTY. REMARKS BATTERY 1 BATTERY SHEET 1 BATTERY BAND 1 BATTERY BOLT SET 2 BATTERY CABLE 1 BATTERY CABLE 1 CABLE..........................................................1.................MAKE LOCALLY HEX HEAD BOLT 1 TOOTHED WASHER 1 HEX HEAD BOLT 1 TOOTHED WASHER 1 DCA70USI3can 60 hz Generator • operation and parts manual — rev.
Muffler Assy. page 68 — DCA70USI3can 60 hz Generator • operation and parts manual — rev.
Muffler Assy. NO. 1 2 3 4 5 6 7 8 9 10 11 PART NO. M2330101103 0017112030 M2333001403 M2333200404 0017110040 M2333200304 0017110035 M2333001303 0017110050 8943690210 0039308000 PART NAME QTY. REMARKS MUFFLER 1 HEX HEAD BOLT 4 EXHAUST PIPE 1 GASKET 1 HEX HEAD BOLT 4 GASKET 1 HEX HEAD BOLT 4 EXHAUST PIPE 1 HEX HEAD BOLT 4 GASKET.......................................................1.................REPLACES P/N 0602320101 U-BOLT 6 DCA70USI3can 60 hz Generator • operation and parts manual — rev.
FUEL TANK ASSY. page 70 — DCA70USI3can 60 hz Generator • operation and parts manual — rev.
FUEL TANK ASSY. NO. 1 1-1 1-1A 2 3 4 5 6 7 8 9 10 11 12 13 14 14A 15 15A 16 17 18 19 20 20A 20B 21 21A 22 23 24 25 26 27 28 29 30 31 32 32A 33 PART NO.
ENCLOSURE #1 ASSY. page 72 — DCA70USI3can 60 hz Generator • operation and parts manual — rev.
ENCLOSURE #1 ASSY. NO. 1 2 3 4 5 5A 6 6A 7 8 9 10 11 12 13 14 15 16 17 18 18A 19 20 21 22 23 24 25 26 27 28 29 29A 30 31 32 33 34 PART NO.
ENCLOSURE ASSY. #1 (continued) page 74 — DCA70USI3can 60 hz Generator • operation and parts manual — rev.
ENCLOSURE ASSY. #1 (continued) NO. 35 35A 35B 35C 36 36A 36B 36C 37 37A 38 38A 39 40 41 41A 42 43 44 45 45A 46 47 48 49 50 51 52 52A 53 54 55 56 57 58 59 60 PART NO.
ENCLOSURE 2 ASSY. page 76 — DCA70USI3can 60 hz Generator • operation and parts manual — rev.
ENCLOSURE 2 ASSY. NO. PART NO. PART NAME QTY. REMARKS 1 M2443001202 REAR FRAME 1 1A M2493305103 ACOUSTIC SHEET 1 2 M2443301803 DUCT 2 2A M2493305904 ACOUSTIC SHEET 1 3 0016908020 HEX HEAD BOLT 12 4 0016910025 HEX HEAD BOLT 4 5 M2444300103 COVER, REAR FRAME 1 5A M2443305204 ACOUSTIC SHEET 1 6 0016908020 HEX HEAD BOLT 3 7 0016908020 HEX HEAD BOLT 3 8 M2443200503 DOOR, REAR FRAME 1 9 M1444600004 WINDOW PLATE 1 10 0037906000 U-NUT 8 10A 0041206000 WASHER, PLAIN 8 11 M9113000002 DOOR HANDLE ASSY.
RUBBER SEALS ASSY. page 78 — DCA70USI3can 60 hz Generator • operation and parts manual — rev.
RUBBER SEALS ASSY. NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 PART NO.
NAMEPLATE AND DECALS ASSY. 51 51A 55 55A 30A 30 3A 36 24 53 53 53A 6 6A 53A 54A 54 page 80 — DCA70USI3can 60 hz Generator • operation and parts manual — rev.
NAMEPLATE AND DECALS ASSY. NO. PART NO.
NAMEPLATE AND DECALS ASSY. 51 51A 55 55A 30A 30 3A 36 24 53 53 53A 6 6A 53A 54A 54 page 82 — DCA70USI3can 60 hz Generator • operation and parts manual — rev.
NAMEPLATE AND DECALS ASSY. NO. PART NO. 33 M9520100404 33A# 34 M9520100503 34A# 35 M9520100603 35A# 36 M9520200003 37 M9520200404 38 M9512200004 39 M9510200304 40 M2560101104 41 M2560100603 40 M3560102204 43 M2560101303 44 M2560101403 45 M3560102504 46 0600500092 47 0021106016 48 M9520000804 49 920214100 49A# 50 49002 50A# 51$ EE57072 51A$ EE57073 53 EE57077 53A EE57078 54$ EE57070 54A$ EE57071 55$ EE57079 55A$ EE57080 56 EE52657 57 EE57074 58 EE57089 PART NAME QTY.
Terms and Conditions of Sale — Parts PAYMENT TERMS 5. Parts must be in new and resalable condition, in the original Multiquip package (if any), and with Multiquip part numbers clearly marked. 6. The following items are not returnable: Multiquip reserves the right to quote and sell direct to Government agencies, and to Original Equipment Manufacturer accounts who use our products as integral parts of their own products. a. SPECIAL EXPEDITING SERVICE Terms of payment for parts are net 30 days.
notes DCA70USI3can 60 hz Generator • operation and parts manual — rev.
Operation and Parts Manual HERE’S HOW TO GET HELP PLEASE HAVE THE MODEL AND SERIAL NUMBER ON-HAND WHEN CALLING United StateS Multiquip Corporate Office 18910 Wilmington Ave. Carson, CA 90746 Contact: mq@multiquip.com MQ Parts Department Tel.