Technical information

Chapter 2: Hardware Interface Description
November 15, 2008 G24-L Module Hardware Description 41
This function is described in detail in “Battery Charger Interface” on page 47.
Table 2-19: Temperature A/D Specifications
Parameter Conditions Min Typ Max Unit
Temperature
Range
Operating range 0 +45
°C
Tolerance 5 %
Resolution 5