Technical Specifications

191
Plated Truss
© 2015 MiTek. All rights reserved.
MSH Adjustable Strap Hangers
The MSH is eld adjustable. The anges can be used in top mount,
face mount, or combination installations. An open back design allows
installation after a member is placed in position.
Materials: See chart
Finish: G90 galvanizing
Options: See chart for Corrosion Finish Options
Codes: See page 11 for Code Reference Chart
Installation:
• Use all specied fasteners. See Product Notes, page 17.
• Web stiffeners are required for I-Joist installations.
MSH
MSH422IFMSH222 MSH426
Double shear nail design
features fewer nails and
faster installation
Uses standard
length nails
Continued on next page
H
D
B
W
Plated Truss
D
22"
3-5/8"
H
D
W
B
Face Max
All header nails used should
be driven into the wide face
of the header.x
Top-Max
The hanger is installed in a top
mount condition with at least
six lower header face nail holes
lled, and four top ange nails
lled. The strap must wrap over
the top at least 2".
Top-Min
The hanger is installed in a top
mount condition with at least
the top two header face nail
holes lled, and four top ange
nail holes lled. The strap must
wrap over the top at least 2"
and the joist nails shall be
installed straight into the joist
for all models.
Combination
Face-Max / Top-Max
Face-Max values apply for
the entire connection. Follow
fastening directions above for
the applicable mounting
condition for each individual
ange strap.
Typical MSH installation
face-mount maximum
Typical MSH installation
top-mount maximum
Typical MSH installation
top-mount minimum
Typical MSH
combination installation
D
23"
1-5/8"
Mounting Conditions

Summary of content (3 pages)