Datasheet
MAX1619
Remote/Local Temperature Sensor with Dual-
Alarm Outputs and SMBus Serial Interface
2 _______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS
(V
CC
= +3.3V, T
A
= 0°C to +85°C, configuration byte = XCh, unless otherwise noted.)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
V
CC
to GND..............................................................-0.3V to +6V
DXP, ADD_ to GND....................................-0.3V to (V
CC
+ 0.3V)
DXN to GND..........................................................-0.3V to +0.8V
SMBCLK, SMBDATA, ALERT, OVERT,
STBY to GND............................................................-0.3V to +6V
SMBDATA, ALERT, OVERT Current....................-1mA to +50mA
DXN Current .......................................................................±1mA
ESD Protection (all pins, Human Body Model) ..................2000V
Continuous Power Dissipation (T
A
= +70°C)
QSOP (derate 8.30mW/°C above +70°C).....................667mW
Operating Temperature Range .........................-55°C to +125°C
Junction Temperature......................................................+150°C
Storage Temperature Range.............................-65°C to +150°C
Lead Temperature (soldering, 10sec).............................+300°C
T
A
= +60°C to +100°C
Monotonicity guaranteed
ADD0, ADD1; momentary upon power-on reset
DXP forced to 1.5V
Logic inputs
forced to V
CC
or GND
Auto-convert mode
From stop bit to conversion complete (both channels)
V
CC
, falling edge
T
A
= 0°C to +85°C
V
CC
input, disables A/D conversion, rising edge
Autoconvert mode, average
measured over 4sec. Logic
inputs forced to V
CC
or GND.
CONDITIONS
µA160Address Pin Bias Current
V0.7DXN Source Voltage
µA
81012
80 100 120
Remote-Diode Source Current
%-25 25Conversion Rate Timing Error
ms94 125 156Conversion Time
µA
120 180
35 70
Average Operating Supply Current
-2 2
Bits8Temperature Resolution (Note 1)
µA
5
Standby Supply Current
310
mV50POR Threshold Hysteresis
V1.0 1.7 2.5Power-On Reset Threshold
°C
-3 3
Initial Temperature Error,
Local Diode (Note 2)
V3.0 5.5Supply Voltage Range
V2.60 2.80 2.95Undervoltage Lockout Threshold
mV50Undervoltage Lockout Hysteresis
UNITSMIN TYP MAXPARAMETER
T
R
= +60°C to +100°C
T
R
= -55°C to +125°C (Note 4)
-3 3
°C
-5 5
Temperature Error, Remote Diode
(Notes 2, 3)
Including long-term drift
-2.5 2.5
°C
-3.5 3.5
Temperature Error, Local Diode
(Notes 1, 2)
0.25 conv/sec
2.0 conv/sec
T
A
= +60°C to +100°C
T
A
= 0°C to +85°C
High level
Low level
ADC AND POWER SUPPLY
SMBus static
Hardware or software standby,
SMBCLK at 10kHz