Installation Guide
ON
4
Mount the switch using the provided screws
5
Turn power ON at circuit breaker
7
Custom settings (optional)
Troubleshooting
6
Installation is complete!
Occupancy Sensing Switch
2
Ensure a ground connection is present
MS-OPS2, MS-VPS2
120 V~ 50 / 60 Hz
LFCA
CFL
AFC
150 W
LED / CFL
2 A
Ballast
200 W
MLV
250 W
Inc. / Hal. / ELV
INC / HAL
®
Use our mobile friendly self-paced
installation tool:
www.lutron.com/wiringwizard
Find more product information:
www.lutron.com/support
- Videos
- Frequently Asked Questions
- Online Chat (8 am – 5 pm EST)
Call us:
U.S.A. | Canada | Caribbean
1.844.LUTRON1 (588.7661) (24/7)
Mexico
+1.888.235.2910
Others
+1.610.282.3800
Help
Ground wire
(bare or green)
REQUIRED
Black
Black
Insert and
twist to
tighten
White wire
Neutral wire(s)
Bare wire
OFF
WARNING: SHOCK HAZARD.
May result in serious injury or death. Turn off power at circuit
breaker or fuse before installing.
1
Turn power OFF at circuit breaker
3
Remove existing device and connect sensor switch
Look for a bare copper wire or green wire (ground), and a white wire
(neutral) coming out of the wall. When a neutral connection is available,
remove the green sleeve and connect the white wire to neutral. Connect
the bare and green-sleeved wire from the device to ground (only in
retrofit and replacement applications). If neither wire is present, consult
an electrician. This device will not function if it is not grounded.
A. When neutral is present in outlet box: remove green sleeve, connect
white wire to neutral.
Leave wallplate off if custom settings are desired.
See step 7; default settings shown in bold.
IMPORTANT
1. CAUTION: To reduce the risk of overheating and possible
damage to other equipment, DO NOT use to control
receptacles or motor loads.
2. CAUTION: For control of permanently installed LED, CFL,
MLV, incandescent, halogen, ELV or electronic ballast
lamp fixtures.
3. Install in accordance with all national and local electrical
codes.
4. A ground connection is required for product to function.
Connect green-sleeved wire to ground only in retrofit and
replacement applications. When neutral connection is
available, remove green sleeve and connect to neutral. If
neither wire is present, consult a licensed electrician.
5. The sensor switch requires an unobstructed view of
room occupants to detect motion.
6. Hot objects or moving air currents can affect the
performance of the sensor switch.
7. For indoor use only. Operate between 32 °F and 104 °F
(0 °C and 40 °C).
8. Clean with a soft damp cloth only. DO NOT use any
chemical cleaners.
9. Once power has been restored, the sensor switch can
be manually turned on or off within the first 30 seconds
but will not automatically control the load for the first
2 minutes.
10. DO NOT exceed twenty (20) devices on a single branch
circuit.
11. DO NOT use with fan loads.
12. Device makes an audible click when turning on/off.
This is normal functionality.
www.lutron.com/support
Limited Warranty:
http://www.lutron.com/TechnicalDocumentLibrary/Sensor_Warranty.pdf
Lutron and Maestro are trademarks of Lutron Electronics Co., Inc., registered in the
U.S. and other countries.
©2013–2019 Lutron Electronics Co., Inc.
English
P/N 0301885 REV B
Please read before installing.
English
For additional Troubleshooting, please visit www.lutron.com/support
Symptom Solution
Lights do not turn on
(or off)
See Important Note #4.
Call our 24/7 support line at 1.844.LUTRON1.
Lights do not turn
on when space is
occupied
Ensure sensor is not set to vacancy mode.
Sensor may be set to “Auto-on daylight sensing”
(ALD), which will not turn on the lights if there is light
in the room.
Lights turn on in
vacancy mode
There is a 15 second grace period following a timeout
where a sensor will turn the lights back on if it senses
motion.
Lights turn on only if
natural light in room
is low
If switch turns on when there is enough natural
light, or if the switch does not turn on when there
is not enough natural light, press the large button
within 5seconds of entering the room. Over time,
this interaction will “teach” the switch your preferred
setting.
Ballast | Balastro | Ballast
Remove wallplate and select your preferred settings from the table below
before proceeding; default settings shown in bold.
For an explanation of these custom settings, see
www.lutron.com/TechnicalDocumentLibrary/048461.pdf
1
“ Timeout” is the delay until the lights go off after the room is vacated. if you manually
turn the light off and re-enter before the timeout, the lights will not automatically turn
on until the timeout period is complete.
2
Short (less than 15-second) timeout for testing sensor coverage. After entering, device
will exit test mode automatically after 5 minutes, or when any button
is pressed.
3
Lights turn on only if natural light in room is low. If switch turns on when there is
enough natural light, or if switch does not turn on when there is not enough natural
light, press the large button within 5 seconds of entering the room. Over time, this
interaction will “teach” the switch your preferred setting.
A) Press and hold the button(s) indicated in the pictures below.
B) The lens will flash once at each setting (always starts at setting 1).
C) The setting is saved after the button is released.
D) Attach wallplate when complete.
Timeout
1
1
Test Mode
2
2 1 minute
3 5 minutes
4 15 minutes
5
30 minutes
Sensor Mode (MS-OPS only)
1
Auto-On and Auto-Off
(Occupancy mode)
2
Manual-On and Auto-Off
(Vacancy mode)
3
Auto-On daylight sensing
3
and Auto-Off
Advanced Settings
1 Motion sensitivity low
2 Motion sensitivity high
3 Return all settings to default
Number of ashesNumber of ashesNumber of ashes
Once power has been restored, the sensor switch will not automatically
control the load for the first 2 minutes.
Ground wire
(bare or green)
REQUIRED
Black
Black
Insert and
twist to
tighten
Green-sleeved
wire
Bare wire
B. If no neutral is present, connect green-sleeved wire to ground.