I(O Stationary Air Compressor Manual For Kobalt Models K7060V K7060HFV K7580V2 For questions concerning this air compressor, please call: 1-866-242-4298. Rev.
PAGE 1 Safety Guidelines - Definitions Before Using the Air Compressor 2 When Installing or Moving the Compressor Before Each Use 3 Follow Safety Precautions for Electrical Connection Plan Ahead to Protect Your Eyes, Hands, Face & Ears When Operating 4 Spraying Precautions Perform These Maintenance Operations 5 Warning Labels Glossary 6 Wiring Starting the Compressor 7-8 9-13 14 Troubleshooting Parts Warranty Statement
Safety is a combination of common sense, staying alert and knowing how your compressor works. Read this manual to understand this compressor.
When installing or moving the compressor 1 6. A minimum clearance of 18 inches between the compressor and a wall is required because objects could obstruct airflow. This compressor is extremely top heavy. The compressor must be bolted to the floor with vibration pads before operating to prevent equipment damage, injury or death. Do Not tighten bolts completely as this may cause stress to the tank welds. 7. The compressor should be located where it can be directly wired to a circuit breaker.
I Follow the safety precautions 1. Follow all local electrical and safety codes, as well as the National Electric Code (NEC) and the Occupational Safety and Health Act (OSHA). for electrical connections 3. Protect wires from contact with sharp objects. 2. Wiring and fuses should follow electrical codes, current capacity and be properly grounded. All electrical connections should be made by a qualified electrician. Plan ahead to protect your eyes, hands, face and ears Dress for safety 1.
Spraying precautions 1. Do Not spray in the vicinity of open flames or other places where a spark can cause ignition. Do Not smoke when spraying paint, insecticides, or other flammable substances. Never point a spray gun at yourself or any other person or animal. Accidental discharge may result in serious injury. Reduce the risk of dangerous environment Be informed about the materials you use .
Find and read all warning labels found on the air compressor. r7i ¸ Air Filter Pressure Porous element contained within a metal or plastic housing attached to the compressor cylinder head which removes impurity from the intake air of the compressor. Device which automatically controls the on/off cycling of the compressor. It stops the compressor when the cut-off pressure in the tank is reached and starts the compressor when the air pressure drops below the cut-in pressure.
A vlvl,,1:i _I I_[,e ALL ELECTRICAL WIRING SHOULD BY A QUALIFIED ELECTRICIAN General Information BE DONE Adequate wiring and motor protection should be provided for all stationary compressors. Wiring used for other machinery should not be used. A qualified electrician familiar with local electrical codes in your area should be used.
Low discharge pressure 1. Compressor too small for application 2. Air leaks 3. Restricted intake air 4. Blown gasket(s) i. Broken or misaligned valves 1. Reduce air demand or use a compressor with more air capacity. 2. Listen for air leaks. Apply a soap solution to all fittings and connections. Bubbles will form at points of leakage. 13ghten or replace fittings or connections. 3. Clean or replace air filter. 4. Replace necessary gaskets. 5. Remove head and inspect for broken or misaligned valves.
Pressure switch unloader constantly leaking air 1. Malfunctioning check valve 1. Replace check valve if unloader bleeds constantly. Do not remove check valve pressure in tank Pressure switch not unloading 1. Malfunctioning switch 1. Replace pressure switch if it does not release air pressure briefly when unit shuts off. Excessive vibration pressure 1. Improper installation 2. Loose belts 3. Misaligned flywheel or drive pulley Overheating 1. Compressor too small for application 2.
KOBALT. Electric Compressors ..
B3800 and NS18S Single Stage Compressor Pumps Filter for NS18S Filter for B3800! @ ! Page 10
B3800 and NS18S Single Stage Compressor Pumps ILLUSTRATION NUMBER 01 O2 O3 04 05 06 07 08 09 10 11 12 13 13a 16 17 18 19 20 21 22 23 24 25 26 27 28 29 31 32 33 34 35 35a 36 37 38 39 4O 40a 41 PART PART DESCRIPTION NUMBER 3660100 3630000 3860400 3860401 3660200 3660160 2840050 1421100 3610100 9140040 9020011 9020041 9020071 FS008 2281000 2060690 2060590 9170030 9024021 9163010 9110014 9004008 3650100 3650201 2850300 2850400 2050500 3670200 9101594 9101144 9101094 9107254 9114273 9101154 9053853 9022001 36
B5900 Two Stage Compressor Pump Page 12
B5900 Two Stage Compressor Pump Illustration Number Description Quantity 1. Crankcase 1 5961101 2. 3. 4. 5. Cylinder Head Crankshaft Crankcase Bottom 1 1 1 1 5930001 5961405 5961200 5961301 6. 7. 8. 9. 10. 11. 12. 13. Valve Assembly Conrod Insert (Half Bearing) Conrod Conrod Nut HP Piston LP Piston HP Wrist Pin LP Wrist Pin 1 4 2 4 1 1 1 1 5940051 9013013 5011101 9128234 5021100 5922100 5021200 5922200 14. 15. 16. 17. 18. 19. 20. 21. 22.
StationaryCompressorLimited Warranty Lowes Kobalt Models K7060V, K7060HFV & K7580V2 Warranty This warrantyof the LowesKobatt StaUonarySingle.Stage Models KT060V and K7060HFV, and StationaryTwo-Stage Modal K7580V2 (hereinafterthe "KoheltProduct') extendsto the edginal userof the Kobait preducL Warranty Duration This Kobait Productis warrantedtothe odginai purchaserfrom the odginaipurchase dateforthree (3) years subjectto the WarrantyCoverage describedherein.