MEASURING A SPECULAR TARGET
When measuring specular targets like glass or mirrors, mount the sensor head at an angle so that reflected laser light returns to the
receiver. When using the LK-H08x or the LK-H15x, use the LK-F3 or LK-F2 neutral density filter.
LK-H02x
LK-H05x
LK-H08x
LK-H02xK
LK-H05xK
DIFFUSE TARGET SPECULAR TARGET
LK-H08x+LK-F3
LK-H15x LK-H15x+LK-F2
+3 mm
+2.8 mm
+5.2 mm
+17.6 mm
+39.5 mm
+10 mm
+18 mm
+40 mm
20 mm
16.1 mm
46.3 mm
76.7 mm
147.5 mm
50 mm
80 mm
150 mm
-3 mm
-2.8 mm
-5.2 mm
-17.6 mm
-39.5 mm
-10 mm
-18 mm
-40 mm
0 mm
0 mm
0 mm
0 mm
0 mm
0 mm
0 mm
0 mm
Reference position Reference position
Reference position
Reference position
Reference position
Reference position
Reference position
Reference position
Measurement range
Measurement range
Measurement range
Measurement range
Measurement range
Measurement range
Measurement range
Measurement range