96M11353 Instruction Manual Laser Displacement Sensors LB-1000(W) Series
CONTENTS SAFETY INFORMATION ON LB-1000 SERIES Safety Information for LB-1000 Series .................................................... 2 This manual describes how to install the LB-1000 Series as well as its operating procedures and precautions. Read this manual carefully for your safety. Safety Precautions on Laser Product ..................................................... 3 Precautions on Regulations and Standards ............................................ 6 Part Names .........................
SAFETY PRECAUTIONS ON LASER PRODUCT 1. Classification 3. Labels location LB-041/ LB-081/ LB-1001(W) LB-1101(W) FDA (CDRH) 21CFR Part 1040.10 Class IIIa IEC/EN 60825-1 Class 2M Class 3R LB-301/ LB-1201(W) IIIb Class 3B 2.
SAFETY PRECAUTIONS ON LASER PRODUCT 4. Safety consideration CAUTION Use of controls or adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure. 1) Class IIIb/3B laser products WARNING Follow the instructions mentioned in this manual. Otherwise, injury to the human body (eyes and skin) may result. • Do not directly look at or touch the laser beam and its reflection from a mirror-like surface.
SAFETY PRECAUTIONS ON LASER PRODUCT 3) Class 2M laser products WARNING Viewing the laser output with certain optical instruments designed for use at a distance (for example, telescopes and binoculars) may pose an eye hazard. Follow the instructions mentioned in this manual. Otherwise, injury to the human body (eyes and skin) may result. • Do not stare into the beam. • Do not direct the beam at other people or into areas where other people unconnected with the laser work might be present.
SAFETY PRECAUTIONS ON LASER PRODUCT For use with shield: PRECAUTIONS ON REGULATIONS AND STANDARDS Attach the shield to the front surface of the sensor head. CE Marking LB-041/LB-081 Applicable Models: LB-041/LB-1001W, LB-081/LB-1101W and LB-301/ LB-1201W Keyence Corporation has confirmed that these products comply with the essential requirements of the applicable EC Directives, based on the following specifications.
PART NAMES Controller 1 Key-operated power switch 2 6 7 1 Indicators TIM: Timing indicator STB: Stability indicator (3-color indicator) BRIGHT: Excessive light quantity indicator DARK: Insufficient light quantity indicator LASER ON: Laser radiation emission warning 2 RESPONSE speed selector switch Used to select response speed (0.4 ms, 10 ms, or 40 ms) 3 SENS (sensitivity) selector switch Used to select WHITE, BLACK, or AUTO mode. 3 4 DIP switches (see p.
CONNECTIONS LB-1001/1101/1201 CAUTION Be sure to confirm the model number. ■ Description of terminals 3 Earth ground terminal * GND terminals 4, 0, and B are connected internally. 5 Alarm output (NPN open-collector) Outputs if light quantity is insufficient or excessive, or when no target is present in the operating range. 6 AUTO ZERO input Connecting this terminal to a GND terminal (4, 0, or B) resets the analog voltage output to 0 V (12 mA for current output).
CONNECTIONS INSTALLATION ■ Description of DIP switches DIP Controller RESPONSE MANUAL MAIN LASER POWER MAX 1 2 3 4 FUZZY SUB AUTO LOCK ZERO FREE The controller can be mounted to a DIN rail. When mounting or removing the controller, pull the claw (bottom center) in the direction of the arrow. The controller can also be screw-mounted using the mounting holes provided. 1 RESPONSE speed mode selector switch To use the FUZZY logic control circuit, set the switch to FUZZY.
SETTING AUTO ZERO/OUTPUT ADJUSTMENT 1. Adjust the distance between the sensor head and target and confirm the position with the LASER ON alarm LED. Set the sensor head so that the laser emitting surface is parallel to the measuring surface of the target, then secure it in place. (See figure below.) Press the AUTO ZERO key to reset the output voltage to zero at the mounting position. Example: LB-041 The LED light green.
MEASURING RANGE VS. ANALOG OUTPUT LB-041/LB-1001(W) LB-301/LB-1201(W) Spot size (mm) 1.4 1.2 3.0 Spot size (mm) LB-041 1.1 1.0 2.2 1.8 2.0 35 mm Measuring range Analog output voltage (V) Analog output voltage (V) 12 7 6 5 (20 mA) 4 3 2 1 37.5 0 -1 (12 mA) 40 42.5 45 200 250 Measuring distance (mm) -2 -3 (4 mA) -5 12 7 6 5 4 3 2 1 0 -1 -2 (20 mA) (12 mA) 300 350 400 Measuring distance (mm) -3 -4 (4 mA) -5 -4 -6 -6 -7 -7 Alarm output (N.C.) 2.
SETTING DIP SWITCH 1 (FUZZY LOGIC CONTROL) To use the FUZZY logic control circuit, set DIP switch 1 to FUZZY (bottom setting). (The switch is factory-set to MANUAL) DIP 1 2 3 4 The FUZZY logic control circuit is used to obtain both stability and high response speed when measuring a target traveling on a production line. FUZZY mode settings • RESPONSE speed selector switch MID Select for normal measurement.
SETTING DIP SWITCH 2 (INTERFERENCE SUPPRESSION FUNCTION) When using 2 sensor heads in close proximity, set the DIP switch of one controller to MAIN, and that of the other to SUB to suppress interference. (This can also be used for synchronized measurement.) Alternating oscillation frequency and ON/OFF ratio (all models) Frequency 30Hz ON/OFF ratio 1:1 A B Synchronous ON (timing) pulse OFF Note DIP 1 2 3 4 Wire as follows.
SETTING DIP SWITCH 3 (LASER POWER CONTROL) SETTING DIP SWITCH 4 (AUTO ZERO) Laser power control AUTO ZERO setting lock DIP 1 2 3 4 DIP 1 2 3 4 When the DIP switch is set to AUTO (bottom setting), emitted laser beam quantity is automatically controlled according to the reflectivity of the target. The switch is factory-set to MAX. DIP switch 4 is factory-set to FREE. In this mode, AUTO ZERO can be performed by either using the key on the controller panel or short circuiting the terminals.
TROUBLESHOOTING If a problem occurs, first apply the remedy given in the troubleshooting guide below. If this does not solve the problem, please contact your nearest distributor or Keyence office. Problem Analog voltage does not change. (Measured value is not indicated.) Cause Sensor head is incorrectly mounted. Remedy Secure sensor head in range where LASER ON alarm LED lights yellow or green. Connector of sensor head is Fully insert connector to make not firmly inserted. proper contact.
HINTS ON CORRECT USE Compatibility AUTO ZERO function lock (DIP switch 4 ) CAUTION The controller and sensor head of the LB-1000 series have been factorycalibrated in pairs. Therefore, in order to satisfy specifications, be sure to use a sensor head and controller having the same serial number.
CHARACTERISTICS (TYPICAL) ■ LB-041/LB-1001(W): 40 mm ± 5 mm ■ LB-081/LB-1101(W): 80 mm ± 15 mm Shift-point adjustment range Shift-point adjustment range Span adjustment range Changes in detection span when target is tilted Span adjustment range Changes in detection span when target is tilted The shift-point adjustment range shows the range where the output voltage reading can be shifted to zero using the SHIFT adjustment trimmer (operates when DIP switch 4 is set to LOCK).
CHARACTERISTICS (TYPICAL) ■ LB-301/LB-1201(W): 300 mm ± 100 mm ■ Frequency characteristic Shift-point adjustment range Common to LB-1001(W), LB-1101(W), and LB-1201(W) RESPONSE speed selector switch set to HIGH Span adjustment range Analog output voltage (dB) 0 -10 915 Hz (-3dB) -20 -30 100 Frequency (Hz) 1K RESPONSE speed selector switch set to MID Analog output voltage (dB) 0 -10 36 Hz (-3dB) -20 -30 10 100 Frequency (Hz) RESPONSE speed selector switch set to LO Changes in detection span whe
SPECIFICATIONS Type Model Sensor head Controller Reference distance Measuring range Light source Output Pulse duration Wavelength Laser FDA (CDRH) 21CFR Part 1040.10 Class IEC/EN 60825-1 Spot diameter (with white paper) Linearity Resolution (at LO mode) Output Analog voltage Impedance Analog current Alarm Adjustment range Zero-point Span Response frequency (-3 dB) Sensitivity Other functions Temperature Sensor head fluctuation Controller Ambient light 2.
SPECIFICATIONS Type Model Sensor head Controller Reference distance Measuring range Light source Output Pulse duration Wavelength Laser FDA (CDRH) 21CFR Part 1040.10 Class IEC/EN 60825-1 Spot diameter (with white paper) Linearity Resolution (at LO mode) Output Analog voltage Impedance Analog current Alarm Adjustment range Zero-point Span Response frequency (-3 dB) Sensitivity Other functions Temperature Sensor head fluctuation Controller Ambient light 2.
DIMENSIONS Unit: mm Sensor head Controller LB-301 LB-041/LB-081 Data in ( ) applies to LB-081. All other dimension are the same for both models. LB-1001(W)/LB-1101(W)/ LB-1201(W) φ 15 φ 15 43 43 φ7 φ7 85 190 4 4 62 190 77 28 38.5 25 54 2 x φ 4.5 mounting hole LASER ON alarm LED LASER ON alarm LED 52 60 56 52 60 56 4 4 35 to 45 (65 to 95) 3 x φ 4.5 mounting hole 28° (18°) 200 to 400 9° Reference position 13 12.5 15.
WARRANTIES AND DISCLAIMERS (1) KEYENCE warrants the Products to be free of defects in materials and workmanship for a period of one (1) year from the date of shipment. If any models or samples were shown to Buyer, such models or samples were used merely to illustrate the general type and quality of the Products and not to represent that the Products would necessarily conform to said models or samples.