Important Safety Instructions About This User Manual Congratulations on your purchase of this IQAir high-performance air cleaning system. Please study this user manual carefully to familiarize yourself with the special features and functions of your IQAir system and keep it in a safe place for future reference. Read these instructions before using the air cleaner: • Do not use this air cleaner as sole protection against harmful pollutants. • Do not immerse the air cleaner in water or other liquids.
Table of Contents Page Important Safety Instructions 1 Chapter 1 – Air Cleaning Systems and Indoor Air Quality 1. 1 Improving Indoor Air Quality 4 4 Chapter 2 – Setting Up 2. 1 Unpacking 2. 2 Choosing a Suitable Location 2. 3 Connecting to Power 2. 4 Fitting and Removing Casters 5 5 6 6 7 Chapter 3 – The IQAir® System’s Components 3. 1 Description of Housing Components 3. 2 Description of Removable Components 3. 3 How the IQAir System Works 9 9 10 10 Chapter 4 – Using the Control Panel 4.
Chapter 1 – Air Cleaning Systems and Indoor Air Quality Chapter 1 – Air Cleaning Systems and Indoor Air Quality 1.1 Improving Indoor Air Quality Air cleaning can play an important role when it comes to improving indoor air quality. However, it should be noted that air cleaning should be used in conjunction with pollution source control and ventilation, wherever possible. Strategy to improve indoor air quality To tackle any indoor air quality problem, keep the following three-step strategy in mind: 1.
Chapter 2 – Setting Up Chapter 2 – Setting Up 2.1 Unpacking To unpack the IQAir system, open the top of the box and remove the square styrofoam pad which contains all accessories and product literature. Lay the box on its side, hold the system by the handle and pull it out of the box. Remove the plastic bag and foam belt. Keep the packaging for future transport and service needs.
Chapter 2 – Setting Up 2.2 Choosing a Suitable Location When choosing a suitable location for the IQAir system, keep the following considerations in mind: min. distance 12” (1 foot) Keep power cord clear of walkways IQAir • Choosing the most suitable room for the system will depend on where you would like the focus of the air cleaning efforts. Two main considerations are the time you spend in a particular room and the location of the main air pollution sources.
Chapter 2 – Setting Up 2.4 Fitting and Removing Casters 1 Attaching the supplied casters is optional. They make it easy to move the air purifier between rooms. 2 The caster kit consists of: 1. mounting rail ( x 2) 2. casters ( x 4) 2 1 For installation simply follow the below instructions: 2 aped crescent-sh s cut-in Turn the device upside down on a soft and clean surface. Place the mounting rail on the purifier’s base so that the holes line up with the black connector pins on the base.
Chapter 2 – Setting Up Removing Casters From Your IQAir® Air Purifier 1 2 Switch the device off. Turn the device upside down on a soft and clean area or surface. 4 3 There are two slotted tabs on each rail. Remove each caster from the rail by pulling it straight off. The caster pins will be exposed. 5 6 Using a flat-head screwdriver, press firmly into the slotted tab. 8 Use the screwdriver to gently loosen and lift the rail away from the base. Lift the rail out by hand.
Chapter 3 – The IQAir® System’s Components Chapter 3 – The IQAir® System’s Components 3.1 Description of Housing Components The IQAir system features a modular tower design in which all important filtration and air moving components are positioned vertically in-line, i.e. stacked on top of another. Air is drawn into the system at the base, and passes through several filter stages to be returned to the room via the diffuser on top of the system. The housing modules are held together by two locking arms.
Chapter 3 – The IQAir® System’s Components 3.2 Description of Removable Components The IQAir system features a modular housing design which enables the easy replacement of all filter elements in a matter of seconds. The illustration below shows all the removable components. For more details on how to replace filters, please refer to Chapter 6 – Replacing Filters. EvenFlow Diffu se r Frame 3 HyperHEPA Filter Frame 2 V5-Cell Filter (HealthPro Plus Only) Filter Clamps Frame 1 PreMax Pre-Filter 3.
Chapter 4 – Using the Control Panel Chapter 4 – Using the Control Panel The IQAir system is operated and controlled via the electronic control panel which is located at the top of the front locking arm.
Chapter 4 – Using the Control Panel Menu Key The Menu key allows access to any one of eleven menus. Pressing the Menu key once allows access to the first menu function. Pressing the Menu key twice allows access to the second menu function, and so on. If no key is pressed for 15 seconds in a menu window, the display will revert to the main display window. Tip: If you are in a menu window and would like to remain in the window for more than 15 seconds, keep the key depressed.
Chapter 4 – Using the Control Panel 4.3.2 Air Exchange Rates in Differently Sized Rooms Any air cleaner can only be effective if it filters a sufficient amount of air in an indoor environment. For general air cleaning purposes, the IQAir system should be able to filter the room air volume at least twice every hour on the set fan speed to achieve a significant air quality improvement.
Chapter 4 – Using the Control Panel 7. Filter Life Reset Allows the resetting of the filter life counter after replacing a filter. 8. Airflow Units Allows to switch the airflow units between cfm (cubic feet per minute) and m3/h (cubic meters per hour). 9. Language Allows to switch the display language. 10. Current Model Allows to update the control panel for an upgrade from a HealthPro to a HealthPro Plus model. 11. Service Access This menu is designed for factory access only. 4.4.
Chapter 4 – Using the Control Panel 4.4.3 Setting the Auto Timer The Auto Timer Menu allows the setting of a Timer ON period, which is defined by a START time and a STOP time. For the Timer ON period, a fan speed can be selected in the Timer ON Fan Speed Menu (see 4.4.5). The time outside the Timer ON period is defined as the Timer OFF period for which the air cleaner can be switched off or for which a different fan speed can be selected in the Timer OFF Fan Speed Menu (see 4.4.5).
Chapter 4 – Using the Control Panel 4.4.4 Day-of-the-Week Timer The Day-of-the-Week Timer allows the deactivation of the Timer ON period on certain days of the week. In its default setting the Timer ON period is enabled on all seven days of the week. This is indicated by stars below the abbreviations of the days. On days without a star the air cleaner will be running at the speed which is set in the Timer OFF Speed Selection Menu (see 4.4.5).
Chapter 4 – Using the Control Panel 4.4.6 Timer Information in the Control Panel The IQAir control panel shows the timer status without the need to access the Timer related menus. Timer Deactivated Display’s Main Window System on Standby: The first line shows the model name and the second line shows the word “Standby”. The Timer LED is red, when the time is not set. System Running: The first line shows the fan speed and the second line shows the airflow. The Timer LED is off.
Chapter 4 – Using the Control Panel 4.4.7 Time & Day Setting When the IQAir system is first connected to the power, the day and time displayed will be incorrect and will have to be set for the timer function to work properly. Once the current day and time are set, they will only need to be reset if the unit is disconnected from the power supply for more than an hour. 1. To access the Time & Day function from the main display window, press the Menu key six times. 2.
Chapter 4 – Using the Control Panel 4.4.9 Changing the Airflow Units 1. You can reach the airflow units menu by pressing the menu key eight times. 2. You can change the airflow units which are displayed from cubic feet per minute (cfm) to cubic meters per hour (m3/h), and vice versa, by pressing the Enter key for three seconds either when the system is switched on or in standby mode. 3. When the first character of the airflow units starts to flash, press the key once to change the units. 4.
Chapter 5 – Using the Remote Control Chapter 5 – Using the Remote Control In addition to the control panel, the IQAir system can be controlled by using the hand-held remote control. The remote control can be used to: • Switch the system on and off • Select the desired fan speed • Activate and deactivate the timer function (Note: Start and stop times can only be set and changed directly on the system’s control panel) 5.
Chapter 6 – Replacing Filters 5.3 Replacing the Battery of the Remote Control When the battery becomes weak, the transmission results will deteriorate and the battery should be replaced. The remote control requires one CR2025 battery. The battery compartment is located at the bottom end of the remote control. To open the battery compartment, press the small lever to the side and slide the battery compartment out. Remove the used battery and insert the new battery.
Chapter 6 – Replacing Filters 6.3 Opening and Closing the Housing The stacked housing elements are held together by two locking arms that hook into the diffuser. To open the system, follow the steps below. 1. Disconnect the IQAir system from the power supply before attempting to open the system. 2. Press the first locking arm outward, using both thumbs as shown. Press just hard enough to release the arm from its snap-in position in the diffuser. Disengage the other arm in the same way. 3.
Chapter 6 – Replacing Filters 4. Remove the filter clamps that secure the filter in the frame by pulling these out of the sliding grooves. 5. Turn the frame over so it is upside down. 6. With the palm of the hand, press down on the filter and loosen the frame. 7. Lift the frame from the filter. 8. Dispose of the used filter by placing it into the plastic bag in which the new filter is supplied (see section 6.7). 9. Turn the frame over (right side up again) and insert the new filter.
Chapter 7 – Maintenance 6.6 Replacing the HyperHEPA® Filter (F3) HyperHEPA filter Diffuser Frame 3 Frame 3 1. Open the locking arms, making sure they are fully extended outward. For details, refer to section 6.3. 2. Opening the arms will release the top housing modules. Removing the diffuser will reveal the HyperHEPA filter inside Frame 3. 3. Remove Frame HyperHEPA filter. 3 containing 4. Turn the frame over so it is upside down. 5.
Chapter 7 – Maintenance 7.3 Technical Support and Repairs Should technical issues or questions arise during or after the warranty period, please contact your point of purchase or call IQAir Technical Support at 888-560-1020 (toll free) or visit: www.iqair.com/support. To expedite your service request, please have the following information ready when contacting us: 1. IQAir model, shell number and serial number (found at the base of the unit and on the certificate of performance) 2.
Chapter 8 – IQAir® Optional Accessories Chapter 8 – IQAir® Optional Accessories IQAir advanced air cleaning systems can be complimented with a range of special IQAir accessories. Ask your authorized IQAir dealer for details. InFlow™ Complete ducting adapter kit for the creation of positive pressure (if placed within the room) and negative pressure (if placed outside the room). PF40™ Additional pre-filter for areas with high levels of coarse dust.
Technical Specifications 27
091216_IQ_MA_HP_US www.iqair.