Keypad Dimmer Owner’s Manual 2334-222 Page 1 of 24 Rev: 7/25/2013 9:16 AM
About Keypad Dimmer ............................................................................................................................................... 3 Features and Benefits ............................................................................................................................................... 3 Before Installation .......................................................................................................................................................
About Keypad Dimmer Congratulations on your purchase of the elegant, high quality Keypad Dimmer. This in-wall switch with a built-in dimmer can control up to 5 or 8 INSTEON/X10 scenes. Additionally, each button has an LED that can be easily configured as a status indicator for virtually any INSTEON device/scene you wish to monitor. Finally, it comes equipped with INSTEON’s patented dual-band communication technology for the most simple, reliable, brilliant remote control available.
Before Installation CAUTIONS AND WARNINGS Read and understand these instructions before installing and retain them for future reference. This product is intended for installation in accordance with the National Electrical Code and local regulations in the United States or the Canadian Electrical Code and local regulations in Canada. Use indoors only. This product is not designed or approved for use on power lines other than 100VAC- 277VAC 50/60Hz, single phase.
Installation – Circuit with 1 Switch 1) Turn off circuit breaker(s) which feed the switch junction box (or remove fuse(s)). Verify that the power is off.
. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19.
Installation – Circuit with 3 (or more) Switches Circuits with 3 switches are called 4-way circuits, circuits with 4 are called 5-way, and so on. All switches in multiway circuits need to be replaced by either a Keypad and/or SwitchLinc). 1. Turn off the circuit breaker(s) which feed power to any of the switch junction boxes (pull fuse(s)) 2. Pull all switches out of their junction boxes. (2 of the switches will have 3 wires connected; the rest of the switches will have 4 wires connected) 6 3.
Local Control LEDs Button LED Meaning ON On All on OFF On All off MAIN On/Off On All on MAIN On/Off Off All off Scene button On Scene members are on Button Taps Button Type Button LED State before Tap Effect of Tap Effect of Double-tap Toggle Off Turn scene On Turn scene members on instantly Toggle On Turn scene Off Turn scene members off instantly Always On Either Turn scene On Turn scene members on instantly Always Off Either Turn scene Off Turn scene members off insta
INSTEON Setup A scene consists of 1 or more INSTEON devices that respond to 1 or more INSTEON controller(s). When the scene is activated (turned on), all scene members return to the states they were at when the scene was programmed. INSTEON scenes let you activate dramatic lighting moods at the touch of a button. For example, you can set all the lights in a scene to dim to 50% or turn certain lights on while turning others off, all with the tap of a button on any INSTEON controller.
Adding Keypad Button to a Scene as a Responder 1) Press and hold the scene controller button until it beeps 11 Controller’s LED will blink 2) Tap the Keypad button you wish to be a responder of the scene at least once 3) Tap the button again if necessary to get the button’s LED to the desired state for the scene (press and hold if adding the main scene at a dimmed level) 4) Press and hold Keypad’s Set button until it double-beeps Keypad’s scene button LED will flash once and return to previous state Contr
- Adjust the responder to the desired scene state (for Keypads you must tap the button at least once to reach the desired state).
B’s scene controller LED will blink and Set button LED will blink green 5) Press and hold Switch A’s Set button until it double-beeps (or LED flashes) A will double-beep and its scene controller button and Set button LED will flash B will double-beep and its LEDs will stop blinking 6) Test the group by controlling the load from A and then B The load and A’s and B’s scene controller button LEDs will all remain in sync Example: Scene with any number of “N” members We recommend using home-management softwa
4) Tap the scene button you want to change 5) Press and hold Keypad’s Set button until it beeps The scene button’s LED will begin blinking and Set button LED will blink green All illuminated LEDs on Keypad will brighten to 100% 6) Press and hold Keypad’s Set button it beeps again 7) Press and hold Keypad’s Set button until it beeps a third time The button LEDs will continue blinking and Set button LED will blink red The button LEDs will stop blinking The button function rotates to the next mode in t
2) Press and hold Keypad’s Set button until it beeps. Set button LED will blink green 3) Send the desired X10 Address plus ON 3 times in a row (e.g. send B5-BON-B5-BON-B5-BON) Keypad will double-beep and the Set button LED will stop blinking Remove X10 Address from a Button If you are no longer going to utilize an X10 address associated with Keypad, it is very important that you remove its X10 address.
Adjust Local Settings Each of the Keypad buttons is considered a “scene button,” meaning you can use any of the buttons on Keypad to create INSTEON scenes. Each button will control its own scene, only sending commands to devices linked specifically to that button. Dimmable responders may behave differently, depending on whether you tap, double-tap or press and hold a button to activate/deactivate a scene.
Local On-Level The local on-level is the default brightness level at which the light(s) physically wired to Keypad will turn on. The default local on-level is 100%, but can be set to any one of 33 settings, 32 fixed brightness levels (3% to 100%) or “Resume Bright,” which will result in the light returning to the brightness level it was at prior to being turned off. We recommend using home-management software such as HouseLinc to set the local on-level.
Note: For proper operation, Keypad must be programmed to operate in 6-button or 8-button mode, corresponding to whichever plate is attached. See Configuring for 6 or 8-Button Operation.
Changing Buttons Keypad buttons can be swapped out with custom-etched buttons to customize its appearance. Using a small, flat-edged screwdriver only, carefully pry up on the sides of the keys from the middle of the keypad (when possible). Make sure you are centered on the key so as to catch the small edge located there for this purpose. Please note that behind the buttons are clear plastic filler pieces; these diffuse the buttons’ LEDs’ lights more elegantly.
Specifications General Product Name Keypad Dimmer - INSTEON 6/8-button Scene Control Keypad with Dimmer (Dual-Band) Brand INSTEON Manufacturer Product Number 2334-2xx where xx could be any number between 0 and 9.
Software Configurable Yes, Always RF Range 150’ Open air X10 Support Yes X10 Addresses 256 max, unassigned by default INSTEON Device Category 0x01 Dimmable Lighting Control 6-button models: 0x42 INSTEON Device Subcategory 8-button models: 0x41 Mechanical Mounting Standard, single gang wall box Wires 4, 16 gauge Wires Black - Hot White - Neutral Red - Load Bare Copper - Ground Case Color Clear Set button 1 Plastic UV Stabilized Polycarbonate Beeper Yes LED 1, dual-color greed/red
Troubleshooting NOTE: Unless they have been unlinked, INSTEON devices that had been previously linked to Keypad Dimmer Dual-Band will still respond to button presses, even after a factory reset. The reason is that the INSTEON devices themselves have not been unlinked from Keypad Dimmer Dual-Band. See Removing Keypad Button from a Scene as a Controller. Problem Possible Cause Solution Make sure the circuit breaker is turned on. The LEDs on Keypad are not turning on at all and won't control my light.
Remove the X10 Primary Address or X10 scene address from Keypad. When I try to turn on my light with another Controller, the light turns on, then back off. Keypad may be set up with an INSTEON On-Level at a high brightness and an X10 Primary or scene address On-Level at a low brightness. When I press a button on Keypad, it takes a long time for other INSTEON devices it is controlling to respond.
Circuit Interrupter #MP215AFCP Install power line noise filter between the output and the load. There might be loose Consult an electrician to check the wiring in your connections within your home's home. wiring.
Certification and Warranty Certification This product has been thoroughly tested by Intertek Testing Services, a nationally recognized independent third-party testing laboratory. The North American ETL Listed mark signifies that the device has been tested to and has met the requirements of a widely recognized consensus of U.S.