HP XP7 Continuous Access Journal User Guide (TK911-96002)

Table 3 S-VOL consistency statuses
DescriptionConsistency status
Volume
Only the current pair was split or suspended.
Update sequence consistency between this S-VOL and other S-VOLs in the associated
journal is not ensured.
This S-VOL cannot be used for disaster recovery at the remote site.
This status is indicated when:
- The pair is split by the user using the Suspend Range-Volume (LU) pairsplit option.
- The pair is suspended due to a failure that did not affect the entire journal.
Mirror
The pair was split or suspended along with the other pairs in the associated mirror.
Update sequence consistency between this S-VOL and other S-VOLs in this mirror is
ensured.
This S-VOL can be used for disaster recovery on the secondary system.
This status is indicated when:
- The pair is split by specifying mirror of the pairsplit -r option.
- All pairs in the associated mirror are suspended due to a failure that affects the entire
group; for example, path failure.
- One pair in the mirror was suspended due to a failure that did not affect the entire
group.
Cnt Ac-J PSUE types and behaviors
The primary system suspends a pair and changes its status to PSUE when it detects any of the
following:
The user has released the pair on the secondary system.
An error condition related to the secondary system, S-VOL, or an update operation.
The primary system is unable to communicate with the secondary system.
A Continuous Access Journal suspension condition is detected by the system.
The following describes the types of PSUE status.
DescriptionApplies ToPSUE Type
The primary system detected an error during communication with the
secondary system or during update copying.
P-VOL, S-VOLPSUE, S-VOL
Failure
S-VOL PSUE type is usually PSUE-S-VOL Failure.
RAID Manager may display this as SSWS.
The primary system could not find valid control information in its nonvolatile
memory during IMPL (initial microprogram load). This condition occurs if
P-VOL, S-VOLPSUE, MCU IMPL
the primary system is without power for more than 48 hours (power failure
and fully discharged backup batteries).
The pair was suspended before the initial copy operation was complete.
The data on the S-VOL is not identical to the data on the P-VOL.
P-VOL, S-VOLPSUE, Initial Copy
Failed
RAID Manager may display this as SSWS.
The primary system is powered off.S-VOLPSUE, MCU P/S
OFF
RAID Manager displays this as SSUS.
Monitoring pair activity, status, license capacity 67