FW 05.01.00 and SW 07.01.00 HP StorageWorks CLI Reference Guide for Directors and Edge Switches (AA-RQ7AD-TE, June 2003)

perf.thresholdAlerts.counter.show
169CLI Reference Guide for Directors and Edge Switches
Syntax
show name
Purpose
This command displays the settings for an individual counter threshold alert.
Parameters
This command has one parameter:
Command Example
Root> perf thresholdAlerts counter show checklinks
Output Example
The output from the perf.thresholdAlerts.counter.show command
displays as follows.
Index: 3
Name: Example_CRC_Error_Finder
Ports: 2,4-7,20-24
Counter Statistic: CRC Errors
Increment: 5
Interval: 30
Alert State: Disabled
perf.thresholdAlerts.counter.show
name The name of a threshold alert as defined by the
command perf.thresholdAlerts.counter.addAlert,
described on page 161.