user manual
52 Troubleshooting
When a power supply sensor goes out of range, the Fault/ID LED illuminates amber and an event is
logged to the event log.
Power supply module voltage sensors
Power supply voltage sensors ensure that an enclosure’s power supply voltage is within normal ranges.
There are three voltage sensors per power supply.
Onboard temperature 1 0–70C None None None
Onboard temperature 2 0–70C None None None
Onboard temperature 3
(Capacitor temperature)
0–70C None None None
CM temperature 5–50C<=5C,
>= 50C
<=0C,
>= 55C
None
Table 9 Power supply temperature sensors
Description Normal operating range
Power Supply 1 temperature –10–80C
Power Supply 2 temperature –10–80C
Table 8 Controller module temperature sensors (continued)
Description Normal operating
range
Warning
operating range
Critical operating
range
Shutdown values
Table 10 Voltage sensor descriptions
Sensor Event/Fault LED condition
Power supply 1 voltage, 12V < 11.00V
> 13.00V
Power supply 1 voltage, 5V < 4.00V
> 6.00V
Power supply 1 voltage, 3.3V < 3.00V
> 3.80V