User Manual

Hillstone Hardware Reference Guide
Orange/Always
on
The trial license has expired and there is no
legitimate license installed in the system.
Off The system is running normally.
PS0
Green/Always
on
Power Supply PS0 is running normally.
Orange/Always
on
Power Supply PS0 is running normally, but its fan
has failed. Change the power supply immediately.
Off Power Supply PS0 is powered off or has failed.
PS1
Green/Always
on
Power Supply PS1 is running normally.
Orange/Always
on
Power Supply PS1 is running normally, but its fan
has failed. Change the power supply immediately.
Off Power Supply PS0 is powered off or has failed.
HA
Green/Always
on
Not using HA, this device is the master device.
Green/Blinking
Two devices are in an HA cluster. This device is
working as the master.
Orange/Blinking
Two devices are in an HA cluster. This device is
working as the slave.
Red/Blinking HA function has failed.
Off High Availability is disabled.
FAN
Green/Always
on
The cooling system is running normally.
Orange/Always
on
One of the fans has failed, but the cooling system
can still fully function. Change the fan tray as soon
as possible.
Red/Always on
The cooling system has a serious error or the fan
tray is
not fully inserted. The system will
automatically shut down in 15 seconds.
VPN
Green/Always
on
The VPN tunnel is connected.
Orange/Always
on
VPN is turned on but no tunnel is connected.
Off VPN is not in use.
SD
Green/Always
on
SD card has been inserted and is in normal status.
Green/Blinking SD card is transmitting data.
Off No SD card is inserted.
LNK
Green/Always
on
The link between this port and its peer device is in
normal status.
Off
The link between this port and its peer device has
failed.
ACT
Orange/Blinking The port is sending or receiving data.
Off No data is transmitted on this port.
e0/0-
e0/8
Green/Always
on
The link between this port and its peer device is in
normal status.
Green/Blinking The port is sending or receiving data.
3
Chapter 1 Introduction
| Hillstone