Attach feeder tube provided with coil and tighten in place. (Separate Photo Sequence Below) 11. Remove the cap from the suction line.
. Release the pressure in the coil by pressing the Shrader valve down until all nitrogen has been released from the unit.
. Unscrew feeder tube completely from the evaporator coil.
. Here is the feeder tube removed from the evaporator coil.
. Unscrew hex nut completely from the liquid line on the evaporator coil.
. Here is the hex nut removed. NOTE: LEAVE IN WHITE O-RING.
. Slide the feeder tube through the back end of the hex nut so the flared end faces out.
. Re-attach hex nut, with feeder tube pulled through the nut, to the coil. Flared end facing out.
. Here is what the finished product should look like.