JGAS640 QGAS740 LP Conversion

Low setting adjustments must be made with other burners in
RSHUDWLRQRQDPHGLXPVHWWLQJ7KLVSURFHGXUHSUHYHQWVWKH
ORZÀDPHIURPEHLQJVHWWRRORZUHVXOWLQJLQWKHÀDPHEHLQJ
extinguished when other burners are turned on.
A. Turn on all surface burners to medium setting.
% 7XUQWKHNQRERQWKHEXUQHUEHLQJDGMXVWHGWR³/2´
& 5HPRYHWKHNQREDQGLQVHUWDVPDOOÀDWEODGHVFUHZGULYHU
LQWRWKHYDOYHVKDIWDQGRUVLGHDGMXVWPHQWVFUHZVDV
shown and turn clockwise to fully tighten down the bypass
VFUHZV5HSHDWIRUDOOYDOYHV
' ,IÀDPHDSSHDUVWRRORZRUXQVWDEOHVORZO\WXUQE\SDVV
VFUHZFRXQWHUFORFNZLVHXQWLODVWDEOHÀDPHH[LVWVIRUHDFK
burner. Remember, other burners must be turned on to
medium.
( $GGLWLRQDOO\IRUHDFKEXUQHUEHLQJDGMXVWHGTXLFNO\RSHQ
DQGFORVHWKHRYHQGRRUZKLOHREVHUYLQJÀDPH,IÀDPHLV
extinguished, continue adjusting bypass screw for a larger
ÀDPH5HSHDWGRRURSHQLQJVXQWLOÀDPHLVVWDEOH
F. Replace the knob.
CONVERTING THE OVEN BURNERS
ADDITIONAL INFORMATION
BAKE BURNER ORIFICE
 5HPRYHRYHQUDFNVGRRUDQGRYHQERWWRP5HPRYHWKH
´VFUHZVVHFXULQJWKHEDNHEXUQHU
 7KHEDNHEXUQHURUL¿FHLVRQWKHJDVYDOYHORFDWHGEHKLQG
WKHGUDZHU/LIWWKHEXUQHURႇWKHRUL¿FHDQGDSSO\D´
VRFNHWRQDQH[WHQVLRQWRWKHKH[EDVHRIWKHRUL¿FHRQWKH
JDVYDOYH/RRVHQWKHRUL¿FHE\WXUQLQJFRXQWHUFORFNZLVH
DQGUHPRYH
 6HOHFWWKHSURSDQH/3EDNHRUL¿FHIURPWKHNLWDQGLQVWDOO
LWRQWKHJDVYDOYH7LJKWHQXQWLOVQXJ
Lift
Burner
%DNH%XUQHU2UL¿FH
ADJUSTING LOW FLAME SETTING
ON COOKTOP BURNERS
SPECIAL NOTE:
To convert the oven back to natural gas, reverse the
instructions given in making propane (LP) adjustments.
NOTICE:
7KLVSURGXFWFDQQRWEHFRQYHUWHGWRSURSDQH/3E\
DGMXVWLQJWKHRYHQRUL¿FHV7KHRUL¿FHVPXVWEHUHSODFHG
for propane (LP).
NOTICE:
2QFHWKHFRQYHUVLRQLVFRPSOHWHDQGFRQ¿UPHG¿OO
out the propane (LP) sticker and include your name,
RUJDQL]DWLRQDQGGDWHFRQYHUVLRQZDVPDGH$SSO\WKH
sticker to the range near the regulator to alert others in the
IXWXUHWKDWWKLVDSSOLDQFHKDVEHHQFRQYHUWHGWRSURSDQH
/3,IFRQYHUWLQJEDFNWRQDWXUDOJDVIURPSURSDQH/3
SOHDVHUHPRYHWKHVWLFNHUVRRWKHUVNQRZWKHDSSOLDQFHLV
set to use natural gas.
NOTICE:
6DYHWKHVHRUL¿FHVIRUIXWXUHFRQYHUVLRQEDFNWRQDWXUDOJDV
PROPANE (LP) CONVERSION INSTRUCTIONS
31-11144 04-18 GEA
JGAS640, QGAS740
198
III
Denotes 1.98mm Orifice size opening
Denotes Natural Gas
N
ADJUSTING AIR SHUTTER SETTINGS
FOR OVEN BURNERS
 :LWKD3KLOOLSVKHDGVFUHZGULYHUORRVHQWKHVFUHZV
securing the air shutter on the bake burner. Adjust the air
shutter to fully open.
2. Turn on the gas.
3. Turn on the electricity.
 5HLQVWDOOWKHRYHQGRRU
5. Turn on the bake burner.
2YHQEXUQHUÀDPHPXVWEHREVHUYHGZLWKWKHGRRUFORVHG
WRSURSHUO\FKHFNÀDPHFKDUDFWHULVWLFV
 $V\RXZDWFKWKHÀDPHZLWKWKHRYHQGRRUFORVHGFKHFN
WKHIROORZLQJWKURXJKWKHRYHQGRRUZLQGRZ
D,IWKHÀDPHVDUH\HOORZRSHQWKHDLUVKXWWHUPRUH
E,IWKHÀDPHVEORZDZD\RUÀXWWHUIURPWKHEXUQHUFORVH
the air shutter slightly.
 &KHFNLQJWKHÀDPHVL]H
,WVKRXOGEHDSSUR[LPDWHO\´WR
´ORQJIRUWKHEDNHEXUQHUV
The combustion quality of the
EXUQHUÀDPHVQHHGVWREH
GHWHUPLQHGYLVXDOO\
127(,IEXUQHUÀDPHVORRNOLNH$IXUWKHUDLUVKXWWHU
adjustment to the bake burner is required. Normal
EXUQHUÀDPHVVKRXOGORRNOLNH%RU&GHSHQGLQJRQ
the type of gas you use. With propane (LP) gas, some
yellow tipping on the outer cones is normal.
)RUHLJQSDUWLFOHVLQWKHJDVOLQHPD\FDXVHDQRUDQJHÀDPHDW
¿UVWEXWWKLVZLOOVRRQGLVDSSHDU
8.
When all adjustments are made and the results are
satisfactory:
a. Retighten the air shutter screws.
E5HSODFHWKHRYHQERWWRP
c. Replace the broil drawer.
Screw
Air shutter
WARNING
,I\RXDWWHPSWWRPHDVXUHWKHLQQHUFRQH
RIWKHÀDPHSOHDVHXVHFDXWLRQEXUQVFRXOGUHVXOW
(A) Yellow flames:
Further Adjustment
Required
(B) Yellow tips on
outer cones:
Normal for Propane (LP) Gas
(C) Soft blue flames:
Normal for Natural Gas
7KHDLUVKXWWHUVVKRXOGEHWXUQHGWRWKHPDUNHGVHWWLQJV1*RU
propane (LP) or set according to the following table.
BURNER
AIR SHUTTER
SETTING FOR PROPANE (LP)
AIR SHUTTER
SETTING FOR NG
Bake Half open Half open
BURNER OUTPUT RATINGS: BTU/HR
NG (Natural) Gas 5” W.C.P.
BURNER
BTU
RATE
ORIFICE
SIZE (mm) COLOR MARKING
RF 15,000 0.070" (1.78) Brown 1
LF 9,500 0.053" (1.36) *UHHQ 1
RR 5,000  White/Purple 1
LR 9,500 0.053" (1.36) *UHHQ 1
29(1 13,000 0.063" (1.61) 1RQH 161