5.3 Host Commands
Error reporting conditions
(1) An undefined code is specified in the FR or SC field (ST = 51h, ER = 04h).
(2) A SATA communication error occurred (ST = 51h, ER = 14h).
At command issuance (Shadow Block O registers setting contents)
CM 1 1 1 0 1 1 1 1
DH x x x x xx
CH
CL
SN
SC
FR
xx
xx
xx
xx or *1 to 3
[See Table 5.6]
At command completion (Shadow Block Registers contents to be read)
ST Status information
DH x x x x xx
CH
CL
SN
SC
E
xx
xx
xx
xx
Error information