• SCT STATUS REQUEST (SN = E0h, FR = D5h)
This command is used to know the status data of SCT shown in Table 5.24 of the
device.
At command issuance (Shadow Block Registers setting)
CM 1 0 1 1 0 0 0 0
DH x x x DV Xx
CH
CL
SN
SC
FR
Key (C2h)
Key (4Fh)
E0h
01h
D5h
At command completion (Shadow Block Registers contents to be read)
ST Status information
DH x x x DV xx
CH
CL
SN
SC
ER
xx
xx
xx
xx
Error information
5-72 C141-E259