Horizon Elite™ Ice Machine Models with RIDE® Technology Installation Instructions for Ice Manager™ Diverter Valve HCD/HCF1810RMS, HCD/HCF2110RMS HCD1810NMS, HCD2110NMS (See model number configurator on page 2 for details.) Order parts online www.follettice.
Chewblet® Ice Machine Model Number Configurations HC Icemaker MC Maestro™ Chewblet® (425 Series) HC Horizon Chewblet (710, 1010, 1410, 1810, 2110 Series) HM Horizon Micro Chewblet 2 Voltage D 1810 A Series 425 up to C 208-230/60/1 (icemaking head) Self-contained only. 425 lbs D 115/60/1 (icemaking head) (193 kg) Self-contained and remote. If remote 710 up to unit, high side is 208-230/60/1. 675 lbs E 230/50/1 (icemaking head) (306 kg) Self-contained only.
Horizon ice machine for use with Ice Manager diverter valve system The Ice Manager diverter valve system delivers ice to two ice storage units enabling a single Follett Horizon ice machine to meet demand for ice at two locations. The system’s sensors monitor ice levels in each storage unit and automatically switch ice delivery to the appropriate location. After thorough review of Ice Manager site survey, read and complete Horizon ice machine installation sections 1 through 6.
Carefully unpack and inspect the contents of your Follett ice machine. 1.
Site preparation Prepare the installation site. 2 Provide drainage, water supply and electrical power to within 6 feet (2m) of ice machine in accordance with local and national codes. Outdoor installation is not recommended and will void warranty. 2.1 2.1 Installation site requirements NEMA 5-15 ➊ ➋ ➎ 3/8" ∅ (9,5mm) ➍ 7/8" ∅ (22,4mm) ➋ ➌ 2 ft.
Louvered docking assembly Install the louvered docking assembly. 3 BEFORE PROCEEDING Prior to installing the louvered docking assembly, ensure that the drain fitting is oriented (right or left) correctly for your installation. An optional straight drain fitting is also supplied. You may need to remove the back panel of the docking assembly in order to re-orient or change the drain fitting. Replace back panel prior to mounting the docking assembly.
4.2 Undercounter installation requirements Top View ➌ CROSSBRACE Access panel/ door on counter ➊ 3.25" (83 mm) min. 22.25" min. (656 mm) 24" min. (609 mm No Lip ➋ DOCKING STATION • Prior to installing the louvered docking assembly, ensure that the drain fitting is oriented (right or left) correctly for your installation. An optional straight drain fitting is also supplied. You may need to remove the back panel of the docking assembly in order to re-orient or change the drain fitting.
Ice transport tube Install the ice transport tube. 4.2 4 Ice transport tube installation. ➋ Hot Water 160 F (71 C) ➍ ➏ ➎ ➐ ➊ 1/4" ➌ 1' Ice transport tube tips • Insulate entire length of ice transport tube ➊ • Secure ice transport tube ➋ as needed to prevent dips and traps from forming. For long tube runs see guide on page 15. • Pitch ice transport tube at least 1/4" per foot (6,4mm/.
External connections Connect utilities to louvered docking assembly. 5 CAUTION • Plug must be accessible after final installation. 5.1 5.2 Water and drain Refrigerant ➊ ➋ ➊ ➌ ➏ Minimum 8" radius 2 ft. x 1" OD silicone tubing 3/4" barb x 3/4" FPT ➍ • Braze supplied quick-connect lines onto stub-ins ➊. 3/4" MPT x 1" slip ➎ 1" Stand pipe/Drain • Rough-in ice machine potable water supply ➊. 3/8” push-in connection will be made at shut-off valve inside machine • Remove access panel if necessary ➋.
Connect louvered docking assembly to ice machine. 6.1 Ice transport tube installation 6.2 Internal connections 6 Water line ➋ ➊ ➊ • Slide ice machine into louvered docking assembly ensuring that drain tube is fully seated on barbed drain fitting ➊ • Insert ice transport tube all the way into coupling and tighten nut firmly ➋ • Insert potable water line into valve 6.3 6.4 Refrigeration lines ➊ Power cord ➊ • Evacuate line set.
6.6 Power cord TDS switch CLEAN POWER ON HIGH LOW BIN MAKING ICE SLEEP CYCLE TIME DELAY LOW WATER MAINT/CLEAN SERVICE HIGH AMPS HIGH PRES TDS DRAIN CLOG CLEANER FULL 6.
Front cover Install front cover to ice machine. 7.1 7.2 Install condensing unit 7 Install ice machine front cover ➋ ➊ • Slide ice machine cover over machine ensuring that tabs on back of cover slip under louvers on back of louvered docking assembly ➊ • Insert and tighten two screws through cover and into louvered docking assembly • Complete installation of condensing unit or connection to rack system. • Required rack system capacity at 0 F (-18 C) evaporator (EPR supplied by installer).
Long tube run recommendations max. 2 ft (.6m) ➋ ➊ 1/4" 1' • Pitch ice transport tube to allow melt water to drain towards ice machine ➊ • Secure insulated ice transport tube at least every 2 ft (.
remote condensing ICE MANAGER
ICE MANAGER remote condensing 15
Horizon, Horizon Elite, Maestro, Harmony, Ice Manager, SafeCLEAN, Sani-Sponge and Vision are trademarks of Follett LLC. Chewblet, RIDE and Follett are registered trademarks of Follett LLC, registered in the US. 801 Church Lane • Easton, PA 18040, USA Toll free (877) 612-5086 • +1 (610) 252-7301 www.follettice.