SINGLE DISHDRAWER TM DISHWASHER DD24SDFT & DD24SV2T models INSTALLATION GUIDE US CA 591385 A 08.
1 ! SAFETY AND WARNINGS IMPORTANT SAFETY INSTRUCTIONS WARNING! Electrical Shock Hazard Before installing the dishwasher, remove the house fuse or open the circuit breaker. If permanently connecting the dishwasher, be sure the power is isolated and the dishwasher unplugged. ● ● ● ● GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.
2 Drain hose support (1) Phillips 5/8” (16mm) screws (7) Drain hose joiner (1) 1 1/2” (38mm) bottom fixing screws & metal washers (2) Wire clip (1) (for securing Drain hose joiner) Rubber washer for inlet hose (1) (comes already fitted) PARTS SUPPLIED Clamp (1) (for securing Drain hose joiner) Moisture protection tape (1) (to prevent moisture damage to cabinetry) Side mounting bracket kit (A and B) (2) OPTIONAL Cavity Bracket Kit (1) (supplied with Fisher & Paykel Tall Height Models only) Top mo
3 3-A OPTIONALLY HARD WIRING PRIOR TO INSTALLATION 3-B REMOVE THE DRAWER REMOVE THE ACCESS COVER & REMOVE POWER To prevent kinked hoses Either sit the drawer down on the left hand side (recommended) or rotate the drawer clockwise, resting it on its side after removal. 1 3 3 1 Clip 1 4 Access cover Push drawer runners back in on either side. 2 1 Sit the drawer down 2 3 00 4” (1 mm) 3 3 4 5 Press the release tabs in on either side and push back to release drawer from runners.
3 3-C OPTIONALLY HARD WIRING PRIOR TO INSTALLATION TERMINATE MAINS WIRING AS SHOWN AND REPLACE MODULE AND COVERS 8 12 8 9 10 9 11 12 14 13 13 11 14 IMPORTANT! Ensure the mains wires are routed UNDERNEATH all other harness wiring from the electronics module. 10 3-D REFIT THE DRAWER ONTO THE RUNNERS & CLOSE 2 Lift or rotate counterclockwise the drawer back onto the drawer runners on either side.
4 PRODUCT DIMENSIONS Handles may vary C H F G A FRONT I PROFILE B PRODUCT DIMENSIONS D E O PLAN 5 DD24SDFT DD24SV2T INCHES (MM) INCHES (MM) 2 17 7/8” (454) A Overall height of product B Overall width of product 23 9/16” (599) 23 13/16” (605) C Overall depth of product 22 9/16” (573) 22 3/4” (578) D Depth of chassis (to back of front drawer panel) 21 3/4” (553) 21 3/4” (553) E Depth of drawer front panel (excl.
5 CABINETRY DIMENSIONS Q K R Bracket slots PLAN PROFILE CABINETRY DIMENSIONS DD24SDFT DD24SV2T INCHES (MM) INCHES (MM) K Inside height of cavity 18 7/8” (480) 17 15/16” (456) L Inside width of cavity 23 5/8” (600) 24” (610) M Inside depth of cavity min. 22 1/16” (560) min. 22 1/16” (560) Minimum clearances from adjacent cabinetry min. 1/2” (13 mm) clearance from a corner cupboard min.
6 CAVITY PREPARATION IMPORTANT! The power outlet must be located in a cabinet adjacent to the dishwasher cavity. 110-120 VAC max. 15 A COUNTERTOP 3/8” (10mm) Moisture protection tape must be applied. Water Connection Recommended HOT (Maximum 140°F/60°C). These marks indicate formed bracket screw locations, if securing by drawer removal. Supplied hose to suit 3/8” (9 mm) male If there is no side partition, you can construct timber bracing as something to secure into. Water Pressure ø max.
7 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE LEFT HAND SIDE RIGHT HAND SIDE Drain hose - 78 1/2” (2000 mm) Drain hose - 70 1/2” (1800 mm) Inlet hose - 49” (1250 mm) Inlet hose - 64 3/4” (1650 mm) Power cord (excl.plug) - 78 1/2” (2000 mm) Power cord (excl.plug) - 78 1/2” (2000 mm) 8 ATTACH CAVITY BRACKET (DD24SDFT MODELS ONLY) IMPORTANT! The enclosed cavity bracket is fitted before installation in order to conceal the gap at the top of the cavity left after installation.
NOW CHOOSE WHICH INSTALLATION METHOD (A) OR (B) IS MORE SUITABLE FOR YOUR CABINETRY... 9 RECOMMENDED METHOD (A) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY) 9-A B ATTACH SIDE MOUNTING BRACKETS Clip all four side mounting brackets into their slots using a flat-bladed screwdriver. Ensure they’re securely fitted before sliding product into cavity. !0-A PULL THROUGH HOSES & PUSH INTO THE CAVITY A B A A B B A The mounting slots are in pairs, one on each side diagonally across the product.
!1-A SECURE TO THE CABINETRY ON THE SIDES 1 Open the drawer halfway. Using a flat bladed screwdriver, prise the grey rubber plug out of the trim moulding. 3 2 Replace the grey rubber plug back into the trim moulding and ensure the trim seal is facing forward. Using a small Philips screwdriver, screw through the trim moulding, securing the side mounting bracket to the cabinetry. Do not damage the rubber trimseal. Repeat for all four brackets.
9 9-B ALTERNATIVE METHOD (B) - SECURE BY DRAWER REMOVAL PULL THROUGH HOSES & PUSH INTO THE CAVITY !0-B REMOVE THE LOWER DRAWER To prevent kinked hoses Either sit the drawer down on the left hand side (recommended) or rotate the drawer clockwise, resting it on its side after removal. 1 3 4 Push drawer runners back in on either side. 2 Sit the drawer down As you push product in, pull through hoses and cord, ensuring they don’t get kinked or twisted.
!1-B SECURE TO THE CABINETRY ON THE SIDES The product has three pairs of fixing points: Ensure the sound insulation is repositioned correctly. 2 two pairs of formed brackets on either side of the chassis (use 5/8” (16mm) screws) a pair of fixing holes either side on the bottom (use 1 1/2” (38mm) fixing screws & washers) 1 !2-B REFIT THE DRAWER ONTO THE RUNNERS 2 Lift or rotate counterclockwise the drawer back onto the drawer runners on either side.
!3 THERE ARE THREE DIFFERENT PLUMBING AND DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE. DRAINAGE OPTION 1 Dishwasher and Ø 1 1/2” (38 mm) Standpipe Screw Drain hose support to back wall at correct height 2 29 1/2” - 34 3/4” (750 - 882.5 mm) If space is limited for fixing, push hose through drain hose support to required height max. 4 3/4“ (120mm) IMPORTANT! step 14 min. 19 11/16” (500mm) 1 1/2” (38 mm) Ensure that drain connection will comply with local plumbing regulations. min.
DRAINAGE OPTION 2 Dishwasher using Air Gap/Break with Drain Hose Joiner Secure drain hose to drain hose joiner and secure to Air Gap/Break 2 1 37 3/8” (950mm) Max. height to top of Air Gap/Break (countertop or wall mounted) step 14 min. R 8” (200mm) IMPORTANT! Ensure that drain connection will comply with local plumbing regulations.
DRAINAGE OPTION 3 Dishwasher using drain hose joiner onto sink trap/waste tee Screw Drain hose support to back wall at correct height 2 29 1/2”- 34 3/4” (750 - 882.5mm) If space is limited for fixing, push hose through drain hose support to required height Supplied drain hose joiner to suit Ø 3/4” (19 mm) waste tee max. 4 3/4” (120mm) 3 step 14 IMPORTANT! Ensure that drain connection will comply with local plumbing regulations. min. R 8” (200mm) Ensure drain hose is routed straight to joiner.
!4 CONNECT INLET HOSE TO HOT WATER !5 SWITCH PRODUCT ON 180o No leaks! Ensure the supplied rubber washer is fitted inside the coupling. Tighten coupling with spanner.
!6 TROUBLESHOOTING ● Excessive water remaining above the filter plate, after the rinse cycle. (This is displayed as an A3 fault. See user guide ‘How to attend to a fault’) Check for a kinked drain hose, blocked or incorrectly drilled out waste connection, highloop not properly installed, drain hose not routed correctly or spray arms not in place. ● No water supply (This is displayed as an A1 fault. See user guide ‘How to attend to a fault’) Check water is connected and turned on.
!7 FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER Check all parts are installed. Ensure that all panels and parts thereof are secure and final electrical tests have been conducted in accordance with local electrical regulations. Turn on the power and water supplies, then open the drawer. You should hear a beep and see a program indicator light up on the control panel. Check the spray arm is in place, mounted correctly and free to rotate, by physically rotating by hand.
19
20