Data Sheet
Nominal Coil Operating range Resistance Rated coil
voltage code
consumption
U
N
U
min
U
max
R I at U
N
VVVΩ mA
3 7.003 2.2 4.5 36 83.5
6 7.006 4.2 9 150 40
9 7.009 6.5 13.5 324 27.7
12 7.012 8.4 18 580 20.7
18 7.018 13 27 1,300 13.8
24 7.024 16.8 36 2,200 10.9
36 7.036 25.2 54 5,200 6.9
48 7.048 33.6 72 9,200 5.2
3
F 43 - Electrical life (AC) v contact current
Contact specification
DC coil data - 0.25 W sensitive (type 43.41)
Coil specifications
Nominal Coil Operating range Resistance Rated coil
voltage code
consumption
U
N
U
min
U
max
R I at U
N
VVVΩ mA
12 9.012 8.4 14.4 360 33.3
24 9.024 16.8 28.8 1,400 17.1
48 9.048 33.6 57.6 5,760 8.3
DC coil data - 0.4 W standard (type 43.61)
Cycles
DC breaking current (A)
• When switching a resistive load (DC1) having voltage and current
values under the curve, an electrical life of ≥ 100·10
3
for 43.41 and
≥ 50·10
3
for 43.61 can be expected.
• In the case of DC13 loads, the connection of a diode in parallel with
the load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
H 43 - Maximum DC1 breaking capacity
DC voltage (V)
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
R 43 - DC coil operating range v ambient temperature
Resistive load - cosϕ = 1
Inductive load - cosϕ = 0.4
limit for 43.41
43.61 current limit
43.41 current limit
I-2014, www.findernet.com
43 Series - Low profile PCB relays 10 - 16 A
43
SERIES
A