INT Devireg™ 550
Thank you for buying a DEVI product. With this purchase you have obtained a product of the highest quality, designed to give long lasting comfort at a minimum of environmental impact.
Contents User Guide 1. Basics.....................................................................................................4 1.1 Safety instructions.....................................................................4 1.2 Functional overview..................................................................5 1.3 Temperature setting ................................................................6 1.4 Changing Battery.......................................................................6 1.
User guide 1.0 Basics • The Devireg™ 550 thermostat controls electrical floor heating elements using a built-in and/or external temperature sensor. • The Devireg™ 550’s adaptive function automatically optimises the unit for the room within a few days after installation and continuously collects updated room data. This means improved performance (with compensation for e.g. sudden temperature drops in the room) and precise timing so the selected temperature is achieved at exactly the right time.
User guide 1.2 Functional Overview Timer on Child lock on Frost protection on Temperature below set value Display Hour display Clock setting active Degree symbol Weekday display Timer setting active Button The thermostat is operated by using the button as follows: Turning clockwise or counter-clockwise to raise or lower values, e.g.
User guide 1.3 Temperature Setting Operation without timer: • The hour display appears as an unbroken ring with a blinking dot indicating the current time (if set). Raise or lower the temperature. • The set temperature appears on the display. • The system maintains the set temperature 24 hours a day. • If the thermostat uses a floor sensor only, the display shows the set temperature on a scale from 1 to 10. • If you lower the temperature to +5 °C, appears on the display.
User guide 1.5 Operating the child lock Press and hold the button. INT While holding, turn steadily counter-clockwise, until “COdE” appears on the display. Turn clockwise to select “0033”. Press to confirm. or appears on the display. • The child lock is on. The thermostat cannot be operated using the button except to switch off the child lock. • The child lock can be switched off using the same procedure as for switching it on. 1.
User guide 2.0 Advanced 2.0.1 Switching the timer on and off The timer is switched on and off by pressing the button. When the timer is on: • appears on the display. • The hour display shows the set comfort temperature periods for the current day as black segments of dots. • The current day is shown on the weekday display. • The system automatically switches between comfort and economy temperatures at the preset times of day. • The economy temperature never appears on the alphanumeric display.
User guide 2.1 Optional Settings 2.1.1 Setting the time and weekday INT Press and hold for 3 seconds. appears on the display. Set the correct time. • A small dot on the hour display shows the currently set time. • When the set time passes 0:00 in either direction, the weekday display changes to the next or previous day (depending on which direction the button is being turned). Press to confirm. disappears from the display. 2.1.2 Setting the timer Press and hold for 6 seconds. appears on the display.
User guide Select the weekday where you want the program to start. Press to confirm. Set the starting time of the first comfort temperature period. Press to confirm. Set the duration of the first comfort temperature period. • The duration is shown as a segment of black dots on the hour display. Press to confirm.
User guide • You have now defined the starting time, duration, and ending time of the first comfort temperature period. • Repeat as required to define subsequent comfort temperature periods. • When the set time passes 0:00 in either direction, the weekday display changes to the next or previous day (depending on which direction the button is being turned). In this way it is possible to program an entire week with different comfort and economy temperatures for each day.
User guide Set the minimum floor temperature. Press to confirm. The display returns to normal. • The floor temperature is kept above the set lower limit. 2.2 Troubleshooting • In case of an error, the hour display starts flashing and the weekday display indicates an error code from 2 to 7. • Refer to the description of error messages in section 6 of the Installation Manual. • If the system does not function correctly, call a qualified electrician. 2.
Installation manual 1.0 Installation overview 1.1 Safety instructions • Make sure the mains supply to the thermostat is OFF before installation. If the thermostat is installed in a network, the INT mains supply to ALL thermostats in the network must be off! • As the Devireg™ 550 is not equipped with an earth terminal, the earthing screen of the heating cable and the earthing wire from the mains supply must be connected to the earth terminal in the surface mounted box or recessed metal box.
Installation manual 1.2 Installation guidelines • Dismantle the thermostat before installation and observe the following guidelines: Place the Devireg 550™ at a suitable height on the wall. In wet rooms, the thermostat should be installed on an even surface according to local building regulations. Place the thermostat at least 50 cm from windows/ doors that will be left open occasionally. Do not place the thermostat on a wall where it will be exposed to direct sunlight.
Installation manual 2.0 System overview 2.1 Three different sensor configurations FS: Floor sensor (comfort heating) • Suitable for floor heating in e.g. bathrooms. The built-in room sensor is not used. • Comfort heating should be used only to supplement a regular room heating system. INT RS: Room sensor (total heating) • Suitable for control of room temperature in e.g. living rooms. Unsuitable for wet rooms. • The thermostat must be mounted in the same room as the heating elements.
Installation manual 2.3 Specifications Temperature range: +5 to +35 °C or OFF Floor temperature limit: +20 to +50 °C Operation voltage: 180-250 VAC, 50/60 Hz Resistive load: 230 V ~ 16A /3680W Inductive load: cos φ 0,3 = Max. 1A Power consumption: < 500 mW Battery back-up: 100 hours Economy set-back: 0 to -30 °C Offset: -5.5 to +5.
Installation manual 3.
Installation manual 4.0 Installation - step by step 4.1 Preparations and guidelines • All necessary cables should be routed to the intended installation point. • The thermostat is designed for installation in a surface mounted box or recessed box with the correct dimensions. • Read and observe the guidelines set forth in section 1.1 and 1.2. 4.2 Dismantling the thermostat Release tab • Push down the release tab. • Carefully detach the front cover. Screws • Remove the two screws.
Installation manual • Carefully detach the display module. The module must be pulled straight out to avoid damaging the 8-pin connector plug on the back of the module! Frame INT • Carefully detach the frame. 4.3 Connecting cables • Connect the cables as shown below. Devireg™ 550 NTC sensor Mains supply 180-250 V 50/60 Hz Heating element Max. load 16 Amp.
Installation manual • Connect wires in heating element and mains supply cables correctly! • Important! Connect the heating cable screen and the mains supply earthing wire to the mounting box earthing terminal. 4.4 Mounting and reassembling the thermostat Screw holes • Mount the base plate on the wall. • Make sure the base plate cannot be moved. • Install the frame, display module, and front cover in the reverse order of disassembly.
Installation manual • Install the display module carefully! • Do NOT over-tighten the mounting screws on the display module. 4.5 Activating the thermostat • Switch on the mains supply. • The unit switches on automatically. • If the unit has never been activated before, configure basic settings as described in section 4.6. 4.
Installation manual Select network status of the thermostat: • MAS Master • SLA Slave • ALO Independent (or network not used) • See descriptions of the possible network configurations in section 5.1. • If a network is not used, choose ALO. Press to confirm. • The adaptive function of the Devireg™ 550 can be switched off. Select status for adaptive function: • AdAP Adaptive function on • OFF Adaptive function off Press to confirm.
Installation manual Select the desired sensor configuration: • rFS Room and floor sensor • FS Floor sensor • RS Room sensor • See descriptions of the possible sensor configurations in section 2.1. Press to confirm. Select the desired maximum floor temperature. • (This does not apply if the thermostat is configured to use a room sensor only.) Press to confirm. • To protect the cables, the maximum floor temperature is factory preset to 35 °C.
Installation manual • The temperature display can be calibrated (offset) so the thermostat shows the same temperature as another thermometer in the room. • (This does not apply if the thermostat is configured to use a floor sensor only.) Select the desired offset value. Press to confirm. • Setting the offset value only recalibrates the thermostat’s temperature reference point and does not adjust heating element power.
Installation manual Press to confirm. • If normal room heating is installed, we recommend lowering the temperature by no more than approx. 5 °C during economy periods. Press to save the settings. • The display returns to normal.
Installation manual 5.0 Optional settings 5.1 Network setup Each network must contain one (and only one) master unit (MAS). • All other units must be either slave units (SLA) or independent units (ALO). • Independent units in the network will not respond to or send information to a master unit. However, they still count towards the network maximum of 32 units. • The following settings on all slave units are controlled from the master unit. All other settings must be configured on each thermostat.
Installation manual cross section) or 500 m (1.5 mm2 wire cross section). • The thermostat network can be controlled remotely using e.g. WEB•HOME™ or Devicom™ PC Pro. Further information on how to connect and use these products can be found in the respective user guides.
6.0 Trouble-Shooting Diagram Error code Problem Solution 2 The thermostat is configured as master in the local network but has detected another master Reconfigure one of the master thermostats as slave or independent. 3 The thermostat is Reconfigure one of the thermostats configured as slave in as master, or configure all units as the local network but independent.
7.0 Factory Settings Item Factory setting Options Network type Alone (ALO) Independent (ALO) Master (MAS) Slave (SLA) Adaptive function On (AdAP) On (AdAP) Off (OFF) Sensor Room + floor sensor (FS) Floor sensor (FS) Room sensor (RS) Room + floor sensor (FS) Max. floor temperature +35 °C +20 to +50 °C Offset 0 °C -5.5 to +5.5 °C Economy set-back -5 °C -1 to -30 °C Weekday 1 1 to 7 Time Not set Normal 24 hour clock Timer Not set Up to 336 settings/week INT k °C -15 -10 .
The 2 Year DEVI Warranty: You have purchased a Devireg™ 550 thermostat, which forms an integrated part of a Deviheat™ system, which we are certain will improve your home comfort and economy. Deviheat™ provides complete heating solutions with Deviflex™ heating cables or Devimat™ heating mats, Devireg™ thermostats and Devifast™ fitting bands.
2 YEAR WARRANTY Warranty Certificate The DEVITM Guarantee is granted to: Name: Address: City: INT Country: Telephone: Attention: The Warranty Certificate must be completed correctly for the Warranty to be valid. Please read the Warranty conditions on the previous page.
Article No.: 08095121 Version - 05.02 International DEVI A/S Tel: +45 7488 8500 Fax: +45 7488 8501 www.devi.com DEVI Heating Systems Ltd. Tel: 02 9997 2811 Fax: 02 9997 7852 www.devi.com.au New Zealand DEVI Heating Systems Ltd. Tel: 33 48 00 70 Fax: 33 48 00 67 www.devi.co.nz VICKJ402 Australia 11/2009 United Kingdom Danfoss Randall Ltd. and Ireland Tel: 0845 121 7400 Fax: 0845 121 7515 www.danfoss-randall.co.