Users Guide

Related Commands
show protocol-tunnel — displays tunneling information for all VLANs.
show running-cong — displays the current conguration.
show protocol-tunnel
Display protocol tunnel information for all or a specied VLAN-Stack VLAN.
Syntax
show protocol-tunnel [vlan vlan-id]
Parameters
vlan vlan-id (OPTIONAL) Enter the keyword vlan then the VLAN ID to display information for the
one VLAN. The range is from 1 to 4094.
Defaults none
Command Modes EXEC
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
Version Description
9.8(1.0) Introduced on the Z9100-ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on the C-Series, and E-Series.
7.4.1.0 Introduced
Example
Dell# show protocol-tunnel
System Rate-Limit: 75 frames/second
VLAN Protocols Interface
1000 STP,PVST Gi 5/7,Gi 5/6
1001 LLDP,GVRP Gi 5/7,Gi 5/6
1002 MMRP,MVRP Gi 5/7,Gi 5/6
1003 LACP,DOT1X Gi 5/7,Gi 5/6
1004 OAM,PAUSE Gi 5/7,Gi 5/6
1005 E-LMI Gi 5/7,Gi 5/6
Example (Specic
VLAN)
Dell# show protocol-tunnel vlan 2
System Rate-Limit: 1000 Frames/second
Interface Vlan Protocol(s)
Gi1/2 2 STP, PVST
Dell#
Service Provider Bridging 1465