Users Guide
Default The SFM is online by default.
Command Modes CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
Version Description
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
7.5.1.0 Introduced on the C-Series.
Usage Information When you insert or remove a secondary RPM with logical SFM, the system must add or remove the backplane
links to the switch fabric trunk. To avoid trac disruption, use this command when you insert the secondary RPM.
When you execute this command, the logical SFM on the standby RPM is immediately taken oine and the SFM
state is set as “standby”.
NOTE: This command could aect trac when taking the secondary SFM
oine.
Example
Dell# show sfm all
Switch Fabric State: up
-- Switch Fabric Modules --
Slot Status
--------------------------------------
0 active
1 active
Dell# configure
Dell(conf)# redundancy sfm standby
Taking secondary SFM offline...
!
Dell(conf)# do show sfm all
Switch Fabric State: up
-- Switch Fabric Modules --
Slot Status
-----------------------------------------
0 active
1 standby
Dell(conf)# no redundancy sfm
Taking secondary SFM online...
!
10Dell(conf)# do show sfm all
Switch Fabric State: up
-- Switch Fabric Modules --
Slot Status
-------------------------------------------
0 active
1 active
568