CLI Guide

System.OpenIDConnectServer.DiscoveryURL (Read or
Write)
Table 416. Details of iSystem.OpenIDConnectServer.DiscoveryURL attribute
Description Indicates the discovery URL.
Legal Values String of up to 1024 ASCII characters
Default Value Not Applicable
Write Privilege Not Applicable
License Required
RACADM
Dependency None
System.Power
This group provides power management features for iDRAC.
The following section provides information about the objects in this group.
NOTE: For Dell PowerEdge FM120x4 server with more than one iDRAC, the power is received and shared from CMC.
Hence, the information about power and temperature for individual iDRACs are not displayed.
System.Power.Status (Read Only)
Table 417. Details of System.Power.Status
Description
Represents the device power state, either ON or OFF.
Legal Values
0 — Server is off
1 — Server is on.
Default Value
0 — Server is off
Write Privilege Not Applicable
License Required Not Applicable
Dependency Not Applicable
System.Power.ServerAllocation (Read Only)
Table 418. Details of System.Power.ServerAllocation
Description
Indicates the power allocated to running blades. This value is displayed in both watts and BTU/h units.
Legal Values
0–7928
Default Value Not Applicable
Write Privilege Not Applicable
License Required Not Applicable
Dependency
None
Database Objects With Get and Set Commands 243