Installation guide
36" Typ.
(914 mm)
O0
• Warming drawer
Warming drawer
120 Vac
electrical
outlet
00
_E_,,- 3/4" Min.*
C (19 mm)
C
--3/4" Min.*
(19 mm)
Cooktop
1 1/2" (38 mm)
_/Typical countertop
Warming drawer
_----- A ------_
B
" 120 Vac
electrical
outlet
NOTES:
27"/30"/36"Dacor I
single oven
Warming drawer 120 Vac_ I
elect. I
Warming drawer 120 Vac_
elect. J
Toe kick
I" A "1
Cutouts Dimensions
D
C
D
C
3/4" Min.*
(19 mm)
Models EWD36, OWD24 and IWD series
models cannot be installed above or
below another warming drawer (any type).
Model OWD24 is not approved for
installation above, below or adjacent to a
wall oven or a warming drawer, including
the same model.
(B) Min. Width to
Model (A) Cutout Width Adjacent Doors/ (C) Cutout Height (D) Min. Vertical Gap Min. Cutout
Drawers Between Cutouts Depth
ERWD30 28 1/2" (724 mm) 30 1/4" (768 mm)* 9 1/8" (232 mm) 1 1/4" (32 mm)*
EWD24 22 1/2" (572 mm) 24 1/4" (616 mm)* 9 1/8" (232 mm) 1 1/4" (32 mm)*
EWD27 25 1/2" (648 mm) 27 1/4" (692 mm)* 9 1/8" (232 mm) 1 1/4" (32 mm)*
EWD30 28 1/2" (724 mm) 30 1/4" (768 mm)* 9 1/8" (232 mm) 1 1/4" (32 mm)*
EWD36 34 1/2" (876 mm) 36 1/4" (921 mm)* 9 1/8" (232 mm) NA
IWD24 22 1/2" (572 mm) ** 9 1/8" (232 mm) NA
IWD27 25 1/2" (648 mm) ** 9 1/8" (232 mm) NA
24" (610 mm)
IWD30 28 1/2" (724 mm) ** 9 1/8" (232 mm) NA
MRWD27 25 1/2" (648 mm) 27 1/4" (692 mm)* 9 1/8" (232 mm) 1 1/4" (32 mm)*
MRWD30 28 1/2" (724 mm) 30 1/4" (768 mm)* 9 1/8" (232 mm) 1 1/4" (32 mm)*
MWDH27 25 1/2" (648 mm) 27 1/4" (692 mm)* 9 1/8" (232 mm) 1 1/4" (32 mm)*
MWDH30 28 1/2" (724 mm) 30 1/4" (768 mm)* 9 1/8" (232 mm) 1 1/4" (32 mm)*
MWDV27 25 1/2" (648 mm) 27 1/4" (692 mm)* 9 1/8" (232 mm) 1 1/4" (32 mm)*
MWDV30 28 1/2" (724 mm) 30 1/4" (768 mm)* 9 1/8" (232 mm) 1 1/4" (32 mm)*
OWD24 22 5/8" (575 mm) 24 1/4" (616 mm)*** 11 15/16" (303 mm) NA 20 1/8" (511 mm)
PWD27 25 1/2" (648 mm) 27 1/4" (692 mm)* 9 1/8" (232 mm) 1 1/4" (32 mm)*
24" (610 mm)
PWD30 28 1/2" (724 mm) 30 1/4" (768 mm)* 9 1/8" (232 mm) 1 1/4" (32 mm)*
* Bare minimum spacing to allow for ventilation and avoid scraping on EWD, MW and PWD series models.
** On IWD series models or OWD24 without the optional front panel kit: The chassis and the drawer faceplate are smaller
than the cutout. The custom front panel mounts to the drawer faceplate. The height and width of the custom front panel
must exceed the appropriate cutout dimensions (A and C above) to cover the hole. Allow 1/4" minimum additional space
on the top, bottom and sides from the custom front panel edge to prevent scraping against adjacent doors, drawers and
the countertop.
*** OWD24 with optional factory front panel kit only. Bare minimum spacing shown to avoid scraping. Gap above and
below cutout is 3/4" minimum. See ** above for OWD24 with custom front panel.
_mCD_ 5