Planning Guides PDF [0.75MB]
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
9.7
In-line Blowers
ILHSF8, ILHSF10
2/2
Revised
02/10/09
Model
Number*
Power
Requirements**
Blower Rating
ILHSF8
120 Vac, 60 Hz,
3.5 Amp
600 CFM***
620.7 CFM****
ILHSF10
120 Vac, 60 Hz,
4.5 Amp
1100 CFM***
1115.9 CFM****
* All models are thermally protected
** In addition to the hood or raised vent
*** Nominal at 0 inches static pressure
**** Actual at 0 inches static pressure
Model Number Weight
ILHSF8 22 lbs. (10 kg.)
ILHSF10 31 lbs. (14 kg.)
ELECTRICAL ACCESS KNOCK-OUTS
WARNING
To avoid the risk of fire due to the unit overheating:
DO NOT◊ install this blower with a hood or raised vent
that has an internal blower.
DO NOT◊ install more than one blower to increase the
length of the duct run. Even small differences between
blower air flow rates can greatly reduce the air draw by
the hood or raised vent.
NOTE:
1. The above specifications are for reference
only. See the data label on the blower for exact
specifications. If the above specifications vary
from the label on the blower, use the data on the
blower label.
2. Install this blower only with approved Dacor hoods/
vents. See the hood/vent installation instructions
to determine suitability.
GRN
L1
BLU
BLK
GND
N1
Knock-out
Knock-out
Airflow CFM (Cubic feet/minute)
Static pressure - inches of water
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
200 400 600 800 1000 1200
ILHSF10 Blower Performance
Airflow CFM (Cubic feet/minute)
Static pressure - inches of water
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
200400 600800
ILHSF8 Blower Performance