Installation Instructions In- Line Blower Models: ILHSF8, ILHSF10 Suitable for use in a household cooking area. Suitable for use with solid state controls. To complete this blower, the hood assembly must be purchased separately. See the hood installation instructions to determine suitability. Part No. 103719 Rev.
Table of Contents Important Safety Instructions........................................... 1 Important Information About Safety Instructions............... 1 Safety Symbols and Labels.............................................. 1 General Safety Precautions.............................................. 2 Product Specifications...................................................... 3 Product Dimensions.......................................................... 3 Electrical Specifications......................
Important Safety Instructions Important Information About Safety Instructions • • The Important Safety Instructions and warnings in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or operating this or any other appliance. Always contact the Dacor Customer Service Team about problems and conditions that you don’t understand. See Customer Service Information above.
Important Safety Instructions General Safety Precautions To reduce the risk of fire, electric shock, serious injury or death when using this blower, follow basic safety precautions, including the following: warning • Do not install or operate this unit if it has been damaged, dropped, has damaged electrical wiring or is not working properly. If the product is damaged when received, immediately contact the dealer or builder.
Product Specifications Product Dimensions All tolerances: ±1/16”, (±1.6 mm) unless otherwise stated 3/16” (0.5 cm) 6 ½" (16.5 cm) 16 ½" (41.9 cm) 13 ¼" (33.6 cm) Air Flow 2 1/4” (5.7 cm) 13” (33.0 cm) 8” REF (20.3 cm) 8” REF (20.3 cm) 6” (15.2 cm) 13” (33.0 cm) ILHSF8 8 3/16” (20.8 cm) 3/16” (0.5 cm) 9 1/8” (23.2 cm) 19” (48.3 cm) 15 1/4” (38.7 cm) Air Flow 2 1/4” (5.7 cm) 16” (40.6 cm) 8 1/4” (21.0 cm) 15 3/4” (40.0 cm) 10” REF (25.4 cm) 10” REF (25.4 cm) ILHSF10 10 3/4” (27.
Product Specifications Electrical Specifications Installation Planning Electrical Supply Requirements System Layout • The power for this blower is supplied via 1/2” 3-wire conduit (not included) by an approved Dacor hood or raised vent. The conduit is installed between the hood or raised vent and the blower and shall be terminated on each end by a 1/2” UL certified strain relief. The power is turned on and off by the power switch on the approved ventilation device.
Installation Instructions Installation Preparation Verify Package Contents • Blower assembly Parts Required • Four (4) #10 X ¾”, round head screws (suitable for the material the blower will be mounted to) • 1/2” 3 wire conduit with a 1/2” UL certified strain relief on each end (length is determined by in-line blower location). See the Electrical Supply Requirements section for complete specifications. • Also consult the hood or raised vent installation instructions for additional parts required.
Installation Instructions Electrical Installation (continued) 6. Strip the three conduit wires. 7. Connect the white (neutral) wire from the conduit to the N1 blower power terminal (see Figure 1). Tighten the terminal screw firmly into place. IMPORTANT: The neutral terminal on the blower has the BLACK wire from the blower motor connected to it. 8. Connect the black (L1) wire from the conduit to the L1 blower power terminal (see Figure 1). Tighten the terminal screw firmly into place.
Technical Data Blower Ratings Model Number Nominal Rating* Actual Rating* ILHSF8 600 CFM 650.7 CFM ILHSF10 1100 CFM 1115.9 CFM * At zero inches static pressure ILHSF10 Blower Performance 3.5 Static pressure - inches of water Static pressure - inches of water ILHSF8 Blower Performance 3.0 2.5 2.0 1.5 1.0 0.5 0 200 400 600 800 Airflow CFM (Cubic feet/minute) 3.5 3.0 2.5 2.0 1.5 1.0 0.
Notes 8