Planning Guide
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
DMW2420S, ADMWTK, AMTK, AOMTK
Distinctive
®
Microwave Oven
and Built-In Trim Kits
Document # PG12-007
Revised 09/12/14 Page 1/1
24”
(61.0 cm)
19 1/8”
(48.6 cm)
13 3/8”
(34.0 cm)
17 1/2”
(44.5 cm)
B
A
2 3/8”
(6.0 cm)
2 3/8”
(6.0 cm)
24 3/4”
(62.9 cm)
ADMWTK TRIM KIT DIMENSIONS
Trim Kit
Model #
(A) Overall
Width
(B) Trim
Depth
Trim Kit
Overlays
ADMWTK27 26 7/8” (68.3 cm)
3/4” (1.9 cm)
Top: 3/8”
(1.0 cm)
Bottom:
3/8”
(1.0 cm)
ADMWTK30 29 7/8” (75.9 cm)
ADMWTK271 26 7/8” (68.3 cm)
1” (2.5 cm)
ADMWTK301 29 7/8” (75.9 cm)
AMTK27 26 7/8” (68.3 cm)
1” (2.5 cm)
Top: 5/8”
(1.6 cm)
Bottom:
3/4”
(1.9 cm)
AMTK30 29 7/8” (75.9 cm)
AMTK36 35 7/8” (91.1 cm)
AOMTK27 27” (68.6 cm)
1 1/4”
(3.2 cm)
AOMTK30 30” (76.2 cm)
NOTE:
1. Power cord length: 42” (106.7 cm) with three prong plug.
2. 3/4” (1.9 cm) platform (flush with cutout) required.
3. 20” (50.8 cm) minimum interior cabinet depth required
for built-in trim kits.
4. See the Combination Installation (CI) section if installing
with a wall oven or warming oven.
A
18 1/8”
(46.0 cm)
24 3/16”
(61.4 cm)
B
2 3/4”
(9.5 cm
2 3/4”
( )
)
9.5 cm
All tolerances: ±1/16” (±1.6 mm), unless otherwise stated
WARNING
• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
• This appliance must be installed in accordance with the
accompanying installation instructions.
16 3/4"
± 1/16
(42.5 cm)
24 3/8" (61.9 cm)
AMTK/AOMTK
1” min.
a, b
(2.5 cm)
7/8” min.
a, b
(2.2 cm)
18” **
(45.7 cm)
4”
c
(10.2 cm)
4”
c
(10.2 cm)
25 3/4" (65.4 cm)
ADMWTK27[1]
28 1/4" (71.8 cm)
ADMWTK30[1]
MICROWAVE INSTALLATION WITH BUILT-IN TRIM KIT
DMW2420 MICROWAVE SPECIFICATIONS
Shipping weight: 46 lbs.
Circuit required: 120 Vac, 15 Amp. dedicated, grounded, 3-prong electrical outlet
Total connected load: 13.0 Amp. @ 120 Vac, 60 Hz.
Interior dimensions: 10 1/2" H x 17 3/8" W x 18 5/8" D, interior walls are recessed
a
Minimum spacing: Includes additional space to avoid scraping/vibration.
b
5/8” (1.6 cm) for ADMWTK series trim kit.
c
120 Vac 15 Amp. 3-prong electrical outlet must be located in one of
shaded areas shown unless interior cabinet depth is 21" (53.3 cm) or more.
AMTK/AOMTK TRIM KIT DIMENSIONS