planning guide
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
DHW
Discovery
®
30”, 36”, 42” and 48” Wide
Wall Mount Chimney Hoods
Document # PG07-001
Revised 10/27/14 Page 1/1
DHW SERIES OVERALL DIMENSIONS
Chimney
24”
(61.0 cm)
Min. 30 1/4” (76.8 cm)
Max. 42” (106.7 cm)
30” - 36” - 42” - 48”
15”
(38.1 cm)
11 3/4”
(29.8 cm)
5 3/4”
(14.6 cm)
12 1/2”
(31.8 cm)
16 1/4” *
(41.3 cm)
Blower
600 CFM* (1200 CFM* for units with 2 blowers)
with electronic speed control
Blower speeds 4
Lights 12 Vac, 20 Watt halogen
Filters Bafe type, dishwasher safe
Exhaust 8 inch
Finish 430 stainless steel
Total connected
load
120 Vac, 60 Hz.
(see table at right for current rating)
Circuit
requirements
120 Vac, 15 Amp. grounded, dedicated 3-wire
circuit (hot, neutral, ground)
* At zero inches static pressure
MODEL NUMBER
DHW301 DHW361 DHW421 DHW482
Blowers 1 1 1 2
Lights 2 2 3 4
Filters 1 1 1 2
Maximum
current draw
3.4 Amp. 3.4 Amp. 3.6 Amp. 6.8 Amp.
IMPORTANT: The minimum installed distance from the hood to the cooking
surface must be no less than 30 inches. The minimum specified distance
may be higher for the particular range or cooktop in use. Check the
manufacturers specifications for the cooktop or range.
* 18” 1/4 on 48 inch model (DHW482)
GENERAL SPECIFICATIONS
MODEL SPECIFIC SPECIFICATIONS
All tolerances: ±1/16” (±1.6 mm), -0, unless otherwise stated
WARNING
• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
• This appliance must be installed in accordance with the
accompanying installation instructions.
• DO NOT install an additional in-line or external blower to
increase the length of the duct run. Even small differences
between blower air flow rates can greatly reduce the air draw
of the hood.
Maximum Duct Length
The maximum straight duct length for the hood is 50 feet. To determine the
actual maximum duct run, subtract the equivalent length of each elbow,
transition and cap from 50 feet. See the Duct Planning Guide or the
installation instructions for more details.
REAR EXHAUST DIAGRAM
■ Chimney can accommodate up to 10” round
duct work
■ Unit can be installed to exhaust through the
ceiling or through the rear wall (see diagram
below).
Optional Recirculation Kit
(PN AVDH1/AVDH2)
Converts hood to a recirculating
configuration in instances where
exhausting the hood outside the
building is not practical or desired.
Consists of a top cap and 2
charcoal filters. When installed,
the top cap redirects air flow out
the vents in the sides of the hood
chimney assembly. The provided
charcoal filters are installed
underneath the mesh type filters
included with the hood. The
charcoal filters reduce smoke and
fumes before the hood exhaust
is vented into the room. Requires
25 inch long piece of 8 inch round
duct (not included).
Top cap
8 inch
duct