INSTALLATION INSTRUCTIONS Istruzioni di installazione Installatie-instructies Instructions d´installation Instrucciones de instalación Installationsanleitung Instruções de Instalação RMT2 RLT2 RXT2 Universal Tilt Mounts Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description RMT2/RLT2/RXT2
RMT2/RLT2/RXT2 Installation Instructions DISCLAIMER Milestone AV Technologies and its affiliated corporations and subsidiaries (collectively "Milestone"), intend to make this manual accurate and complete. However, Milestone makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product.
Installation Instructions RMT2/RLT2/RXT2 DIMENSIONS-RMT2 16.00 1.00 19.94 MAX 7.87 TOP MOUNTING HOLE TO CENTERLINE NOTCH ON WALL PLATE .34 5.19 16.50 7.00 WALL OPENING 12° MAX TILT 1.96 8.38 11.49 15.75 2.50 CENTERLINE TO BOTTOM OF WALL PLATE OPENING 11.00 -CABLE ACCESS WHEN KICKSTAND IS ACTIVATED - TILTS BACK 5.4° 22.00 DIMENSIONS-RLT2 24.00 16.00 7.00 WALL OPENING 28.69 MAX 1.00 7.87 TOP MOUNTING 1.96 HOLE TO CENTERLINE NOTCH ON WALL PLATE .34 12° 5.19 8.38 16.50 11.49 15.75 2.
RMT2/RLT2/RXT2 Installation Instructions DIMENSIONS-RXT2 32.00 24.00 16.00 1.00 7.00 WALL OPENING 35.94 MAX .34 9.84 TOP MOUNTING HOLE TO CENTERLINE NOTCH ON WALL PLATE 12° 1.96 5.19 8.38 11.49 19.68 19.00 38.00 2.
Installation Instructions RMT2/RLT2/RXT2 LEGEND Tighten Fastener Pencil Mark Apretar elemento de fijación Marcar con lápiz Befestigungsteil festziehen Stiftmarkierung Apertar fixador Marcar com lápis Serrare il fissaggio Segno a matita Bevestiging vastdraaien Potloodmerkteken Serrez les fixations Marquage au crayon Loosen Fastener Drill Hole Aflojar elemento de fijación Perforar Befestigungsteil lösen Bohrloch Desapertar fixador Fazer furo Allentare il fissaggio Praticare un foro B
RMT2/RLT2/RXT2 Installation Instructions TOOLS REQUIRED FOR INSTALLATION 7/32" (5.5mm) 5/16" (7.9mm) 1/2" (12.7mm) #2 PARTS B(1) [right upright] A(1) [wall plate] (RXT2 shown) C(1) [left upright] For below kit, quantities are 4 for RMT2 and RLT2, 6 for RXT2. G(1) Hardware Bag GA(8) M4 x 16mm GE(6) M5 x16mm GI(6) M6 x16mm GL(6) M8 x 20mm GP(8) 1/4"(6.4mm) D(4 or 6) 5/16 x 2 1/2" GB(6) M4 x 20mm GF(6) M5 x20mm GJ(6) M6 x 25mm GM(6) M8 x 30mm GQ(8) 1/2"(12.
Installation Instructions RMT2/RLT2/RXT2 Assembly And Installation Install Wall Plate to Wall - Wood Studs 2 x 4 or 6 WARNING: Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment. Reinforce the structure as required before installing the component.
RMT2/RLT2/RXT2 Installation Instructions Install Wall Plate to Wall - Concrete or Concrete Block WARNING: Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment. Reinforce the structure as required before installing the component.
Installation Instructions RMT2/RLT2/RXT2 Install Brackets to Display WARNING: The minimum hole pattern size is 100mm x 1. (GA-GO) x4,x6,x8 7 100mm for the RMT2 and RLT2 and 200mm x 200mm for the RXT2. 2 4 Lay display face down on protective surface. (GS) x4,x6,x8 6 CAUTION: Using screws of improper diameter may (B) damage your display! Proper screws will easily thread into display mounting holes. 2.
RMT2/RLT2/RXT2 Installation Instructions Install Display to Wall Plate (Views from left side) WARNING: Exceeding the weight capacity can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the combined weight of all components attached does not exceed 125 lbs (56.7 kg) for the RMT2 and RLT2 or 175 lbs (79.4 kg) for the RXT2.
Installation Instructions RMT2/RLT2/RXT2 Switching Interface Brackets (Optional) Tilt Adjustment For wide hole patterns, interface brackets must be reversed. See Table below to determine if this is necessary. 1. Adjust tilt tension adjustment knobs to desired tension. (See Figure 12) 2. Adjust tilt of display by pulling the top of display away from the wall until desired tilt position is reached. (See Figure 12) 3. Tighten tilt tension adjustment knobs to secure tilt position.
RMT2/RLT2/RXT2 Installation Instructions USA/International Europe Chief Manufacturing, a products division of Milestone AV Technologies 8800-002428 Rev00 2013 Milestone AV Technologies, a Duchossois Group Company www.chiefmfg.com 11/13 Asia Pacific A P F A P F A 6436 City West Parkway, Eden Prairie, MN 55344 800.582.6480 / 952.225.6000 877.894.6918 / 952.894.6918 Franklinstraat 14, 6003 DK Weert, Netherlands +31 (0) 495 580 852 +31 (0) 495 580 845 Office No.