INSTALLATION INSTRUCTIONS LVS1U LVSXU ConnexSys™ Video Wall Mounting System Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description LVS1U / LVSXU
LVS1U / LVSXU Installation Instructions DISCLAIMER Milestone AV Technologies and its affiliated corporations and subsidiaries (collectively "Milestone"), intend to make this manual accurate and complete. However, Milestone makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product.
Installation Instructions LVS1U / LVSXU TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS ....................................2 TABLE OF CONTENTS ...............................................................3 LEGEND ......................................................................................4 DIMENSIONS ..............................................................................5 TOOLS REQUIRED FOR INSTALLATION .................................6 PARTS .........................................
LVS1U / LVSXU Installation Instructions LEGEND 4 Tighten Fastener Pencil Mark Apretar elemento de fijación Marcar con lápiz Befestigungsteil festziehen Stiftmarkierung Apertar fixador Marcar com lápis Serrare il fissaggio Segno a matita Bevestiging vastdraaien Potloodmerkteken Serrez les fixations Marquage au crayon Loosen Fastener Drill Hole Aflojar elemento de fijación Perforar Befestigungsteil lösen Bohrloch Desapertar fixador Fazer furo Allentare il fissaggio Praticare un foro
Installation Instructions LVS1U / LVSXU DIMENSIONS LVS1U 3.99 101.4 MIN DEPTH 27.56 [700] MAX DISPLAY PATTERN WIDTH 1.00 25.4 HEIGHT ADJUST 17.47 443.7 DIMENSIONS: INCHES [MILLIMETERS] LVSXU 3.99 101.4 MIN DEPTH 27.56 [700] MAX DISPLAY PATTERN WIDTH 1.00 25.4 HEIGHT ADJUST 17.47 443.7 WALL RAILS NOT INCLUDED IN LVSXU VERSION. WALL RAILS SHOWN FOR DEPTH AND POSITION MEASUREMENTS. 13/16" WALL STRUT SHOWN. IF USING DEEPER CHANNEL ADD IN THE ADDITIONAL DEPTH.
LVS1U / LVSXU Installation Instructions TOOLS REQUIRED FOR INSTALLATION nut driver 7/16" 1/2" 3/8" 7/32" 3/8" 7/16" 1/2" 3/8" 7/16" 1/2" M3 x 6" (included) #2 PARTS Display Hardware Kit (Letters correspond to letters on bag) A (4) M6 x 12 B (4) M6 x 16 C (4) M6 x 30 Concrete and Wood Stud Walls Install Hardware Kit K (4) 5/16" D (4) 3/16" J (4) UX10 x 60 E (4) .75x.344x.
Installation Instructions LVS1U / LVSXU LET’S GET STARTED! Measurements You’ll Need Description Measurement A - Number of displays in each row B - Number of displays in each column C - Width of individual display D - Height of individual display E - Total width - (A) x (C) F - Floor to bottom of display (bottom row) OR Ceiling to top of display (top row) G - 1/2 height of display (D) / 2 H - Display mounting pattern offset. (Only applies to some displays. Calculation instructions on next page.
LVS1U / LVSXU Installation Instructions STRUT CHANNEL REQUIREMENTS (LVSXU) IMPORTANT ! : Strut channel must be made of steel with a minimum yield strength of 33ksi (230MPa), and meeting the profile and dimension requirements outlined. Table 1: Strut Channel Dimension Requirements STEEL THICKNESS DIMENSION (See Figure 2) 14 ga [0.075"] (2.5mm) K = 13/16" (21mm) 12 ga [0.
Installation Instructions LVS1U / LVSXU ATTACHING STRUT CHANNEL OR RAIL 10. Attach upper rails (V) using Fastener Information. (See Table 2) IMPORTANT ! : Reference measurements noted on page 7. 1. Mark distance (F) from floor to desired location for bottom of display OR from ceiling to desired location for top of display (if installing top row first). (See Figure 1) and (See Figure 5) 2. Mark distance (G) from bottom of display (or top of display) to center line of display.
LVS1U / LVSXU Installation Instructions HANGING LVS1U/LVSXU MOUNT ON RAIL wall Preparing Strut Channel (LVSXU only) 1. On the top rail, slide one inner stop clamp (S) into end of strut channel section. (See Figure 6) 2. Fasten outer stop clamp (R) to inner stop clamp (S) using one 1/4-20 x 1/2" hex head screw (T). (See Figure 6) 3. Repeat for each end of each top section of strut channel.
Installation Instructions LVS1U / LVSXU INSTALLING INTERFACE BRACKETS 1. Place displays face down on a soft, non-abrasive surface. CAUTION: Using screws of improper diameter may damage your display! Proper screws will easily thread into display mounting holes. 2. 3. 5. Make sure diamond on interface brackets is even with center of display. (See Figure 10) 6.
LVS1U / LVSXU Installation Instructions ADJUSTMENTS NOTE: The following steps are also referenced on the next page (See Figure 16) and the PowerZone Adjustment guide (Z). 1. Place the level against the front of the display and use knob (#1 in Figure 16) to straighten the tilt. (See Figure 12) 3 3 1 Figure 14 4. Slide latch mechanism until tab sits flush against the interface bracket. 5. Pull tab forward to lock latch mechanism to interface bracket. (See Figure 15) 6.
Installation Instructions LVS1U / LVSXU Figure 16 13
LVS1U / LVSXU Installation Instructions COMPLETING THE INSTALLATION FASTENER INSTALLATION METHODS Cable Management Clips IMPORTANT ! : (See Table 2) for appropriate hardware and pilot hole sizes for various wall types. 1. Place cable clip (Q) into rail and turn 90° in either direction until cable clip is vertical. (See Figure 17) 2. Route cables and RapidDraw release cords along rails, through cable clips. 3. Fasten cables and cords to cable clips (Q) using cable ties (P). Wood Stud 1.
Installation Instructions LVS1U / LVSXU Plywood-Backed Steel Stud 1. Use one #14 x 1-1/2" hex-head washer slot head screw (N) and one 1/4" washer (M) through strut channel or rail. (See Figure 21) If back side of wall is unfinished, drywall must be installed to a minimum of one stud left and right of the stud(s) being used to install the mount. Drywall must be secured to studs with screws a maximum of 12" (305mm) apart down center of stud.
LVS1U / LVSXU Installation Instructions SERVICE RapidDraw Display Release Extending and Retracting Mount The RapidDraw pull cord and display release allows easy service access to any specific display in the video wall. The mounts may be extended and retracted only in a service situation. 1. To Extend Mount: Pull on the RapidDraw release cord designated for the specific mount. 2.
LVS1U / LVSXU 17 Installation Instructions
Installation Instructions LVS1U / LVSXU 18
LVS1U / LVSXU 19 Installation Instructions
LVS1U / LVSXU Installation Instructions USA/International Europe Chief, a products division of Milestone AV Technologies 8800-002523 Rev00 2014 Milestone AV Technologies www.chiefmfg.com 03/14 Asia Pacific A P F A P F A 6436 City West Parkway, Eden Prairie, MN 55344 800.582.6480 / 952.225.6000 877.894.6918 / 952.894.6918 Franklinstraat 14, 6003 DK Weert, Netherlands +31 (0) 495 580 852 +31 (0) 495 580 845 Office No.