ICB Twin SH, ICB SH, ICBA SH INSTALLATION & OPERATING GUIDE BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644 www.bunn.com To ensure you have the latest revision of the Operating Manual, Illustrated Parts Catalog, Programming Manual, or Service Manual, please visit the Bunn-O-Matic website, at www.bunn.com. This is absolutely FREE, and the quickest way to obtain the latest catalog and manual updates.
BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCR/MCP/MCA single cup brewers, thermal servers and ThermoFresh® servers (mechanical and digital) 1 year parts and 1 year labor. 2) All other equipment - 2 years parts and 1 year labor plus added warranties as specified below: a) Electronic circuit and/or control boards - parts and labor for 3 years.
INTRODUCTION This equipment will brew coffee into an awaiting server or airpot. The brewer may have an auxillary hot water faucet. It is only for indoor use on a sturdy and level counter or shelf. Please install in an area where there are no water jet devices. The Infusion Series, similar to the DBC BrewWISE, incorporates a wireless interface system that allows the MHG or DBC Grinders to load certain information into the "programming chip" located inside the handle of the funnel.
USER NOTICES Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition. Replace any unreadable or damaged labels. As directed in the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Administration (FDA), this equipment must be installed with adequate backflow prevention to comply with federal, state and local codes. For models installed outside the U.S.A.
CE REQUIREMENTS • This appliance must be installed in locations where it can be overseen by trained personnel. • For proper operation, this appliance must be installed where the temperature is between 5°C to 35°C. • Appliance shall not be tilted more than 10° for safe operation. • An electrician must provide electrical service as specified in conformance with all local and national codes. • This appliance must not be cleaned by water jet.
ELECTRICAL REQUIREMENTS Refer to Data Plate on the Brewer, and local/national electrical codes to determine circuit requirements. WARNING - The brewer must be disconnected from the power source until specified. WARNING - The power cord must be UL Listed, Flexible Cord Type SO, SJO, SJTO, HSJO or SJOW, Rated 90° C, and the attachment plug cap must be UL Listed, in order to avoid a hazard.
PLUMBING REQUIREMENTS These brewers must be connected to a cold water system with operating pressure between 20 and 90 psi (0.138 and 0.620 mPa) from a 1/2˝ or larger supply line. A shut-off valve should be installed in the line before the brewer. Install a regulator in the line when pressure is greater than 90 psi (0.620 mPa) to reduce it to 50 psi (0.345 mPa). The water inlet fitting is .75-11.5 NH (HOSE THREAD). For convenience an elbow adaptor is provided to convert to a 3/8˝ flare fitting.
OPERATING CONTROLS B A E I D F A I O ENABLE BREW BREW A G BREW B C E O ENABLE BREW BREW C BREW A H G BREW B BREW C C NOTE – For Singles, refer to left side of Twins A. ENABLE BREW ON/OFF SWITCH Pressing the "ENABLE BREW ON/OFF" switch (indicator on) enables the brew circuit (on that side of Twins), and energizes the tank refill circuit. Pressing the switch again (indicator off) stops tank refilling and brewing.
SH Server Indicators Single Twin Lorem ipsum dolor sit NOW BREWING amet, consectetuer 3:09 adipiscing elit, sed diam nonummy Lorem ipsum dolor sit NOW BREWING amet, consectetuer 3:09 adipiscing elit, sed diam nonummy Brewing into right server on Twin. Brewing into server on a Single. On both the Twin and Single has a server status bar on the display will indicate the liquid level in the sever. When server is full the display a full status.
INITIAL SET-UP 1. Insert an empty funnel into the funnel rails of the brew station(s). 2. Place an empty server(s) under the funnel(s). 3. Connect the brewer to the power source. Make sure the corresponding "ENABLE BREW ON/OFF" switch is ON (LED will be lit). 4. Water will flow into the tank and stop when the tank is filled to its capacity. Display will show PLEASE WAIT... TANK FILLING until tank is filled with water. 5.
COFFEE BREWING WITHOUT A SMART FUNNEL AND MHG or DBC GRINDER: 1. Begin each brew cycle with a clean empty brew funnel. 2. Insert a BUNN filter into the funnel. 3. Pour the fresh coffee into the filter and level the bed of grounds by gently shaking. 4. Slide the funnel into the funnel rails of the selected side until it stops. 5. Place an empty server under the funnel. 6. The "ENABLE BREW ON/OFF" switch for the selected side must be ON. Select the desired batch size. 7.
CLEANING 1. The use of a damp cloth rinsed in any mild, nonabrasive, liquid detergent is recommended for cleaning all surfaces on Bunn-O-Matic equipment. Do NOT clean this equipment with a water jet device. 2. Check and clean each sprayhead. The sprayhead holes must always remain open. NOTE - Any buildup on the sprayhead may restrict water flow, and impact your coffee brewing. For consistently great coffee, clean sprayheads weekly.
PROGRAMMING The programming of the brewer is divided into four main catagories: Recipes, Calibration, Settings, and Service. The following function screens are in order of appearance. Each screen will have instructions on how to access and the procedures for programming the various functions of the brewer. IMPORTANT PROGRAMMING NOTES - READ CAREFULLY - To exit the programming mode at any time, press and release either ON/OFF pad located on the front switch panel.
PROGRAMMING (cont.) PROGRAMMING FUNCTIONS - FLOW CHART RECIPES << SELECT CALIBRATION >> << SELECT SETTINGS >> << SELECT SERVICE >> << SELECT >> For more advanced PROGRAMMING information, refer to programming manual 53669.0000 at www.bunn.