WWW.BROAN.
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Cleaning and Maintenance . . . . . . . . . . . . . . . . . 6 Motor Grease Filters Non-Ducted Recirculation Filters Fan Blade Stainless Steel Cleaning Painted Finish Cleaning Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-20 INSTALLATION MANUAL TABLE OF CONTENTS Recommended Tools and Accessories for Installation . . . . . . . . . .
READ AND SAVE THESE INSTRUCTIONS ! Intended for domestic cooking only ! INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER. Register your range hood online at www.broan.com ! WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: • Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
! WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. b) Always turn hood ON when cooking at high heat or when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé). c) Clean ventilating fan frequently. Grease should not be allowed to accumulate on fan, filters or in exhaust ducts. d) Use proper pan size.
Operation Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and fresher. Operate the hood as follows: FAN SWITCH I • II Turns fan on to LOW speed. Turns fan OFF. Turns fan on to HIGH speed. LIGHT SWITCH I • II Turns light on to LOW intensity. Turns light OFF. Turns light on to HIGH intensity.
Cleaning and Maintenance Proper maintenance of the Range Hood will assure proper performance of the unit. MOTOR The motor is permanently lubricated and never needs oiling. If the motor bearings make excessive or unusual noise, replace the motor with the exact service motor. The fan blade should also be replaced. GREASE FILTERS The grease filters should be cleaned frequently. Use a warm dishwashing detergent solution. Grease filters are dishwasher safe.
For ADA compliance installation guidelines, please visit www.broan-nutone.com Recommended Tools and Accessories for Installation • • • • • • • • • • • • • • Measuring tape Phillips screwdriver no.
Contents Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer. Make sure that the following items are included: * FIND INSIDE OF HOOD (1) 7” ROUND DUCT CONNECTOR (1) 3¼” X 10” DAMPER ASSEMBLY* (2) GREASE FILTERS EZ1 COMPONENTS Use this template for marking; do not attempt to cut out the ducting hole through it. NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.
Prepare the Hood 1 ] If present, remove all protective polyfilm from the hood and/or parts. 2 ] Using the tab, remove the grease filters from the hood by pushing down and tilting filters out. 3 ] Remove both screws holding damper assembly to hood. Remove parts bag included with the hood (captured behind the damper assembly).Remove damper assembly from inside the hood and keep the screws for further use. NOTE: Remove the EZ1 brackets from inside the hood by cutting off the tie wrap.
5 ] Remove 7” Round Duct Plate from top/back of hood (see illustration below). 7” ROUND DUCT PLATE 2 SCREWS 6 ] Remove Electrical Power Cable Knockout from top (vertical exhaust) or back (horizontal exhaust) of hood. Install an appropriate strain relief, 1/2” diameter (not included). ELECTRICAL POWER CABLE KNOCKOUT NON-DUCTED INSTALLATION ONLY 7 ] Remove 3 screws retaining the recirculation cover plate (shaded part in illustration below) to the hood. Discard this plate with its screws.
DUCTED INSTALLATION ONLY 8 ] Remove 3¼” x 10” vertical, 3¼” x 10” horizontal, or 7-inch round knockout plate as appropriate for your ducting method (see FIGURES 1 A and 1 B).
Prepare the Hood Location NOTE: Before starting installation, read all the steps of these instructions. Use the illustration below to identify your kitchen cabinet type. FRAMED CABINET FRAMELESS CABINET This manual covers 2 kinds of installation: the standard (without EZ1 brackets) and the EZ1 one-person installation system (using included template and brackets). For the standard installation, go to page 17.
4 ] Drill a 1/8” dia. pilot hole for house wiring, at A location on template. 5 ] Use a sharp pencil or 1/8” drill bit to mark the locations for the appropriate duct access holes (16 locations for 7” round duct, or 4 corner locations for rectangular duct). Remove the template. 6 ] Draw the border for the exhaust ducting by linking its marks (16 for round duct and 4 for rectangular duct), then cut the opening in the cabinet bottom (vertical exhaust) or in the wall (horizontal exhaust).
FRAMELESS CABINET Refer to the marking on brackets to determine the correct installation side and orientation. X Y Z 3X [ \ INSTALLATION MANUAL INSTALLATION 7/64” 14 Align the corresponding bracket to the cabinet side, while placing rear end of bracket against the wall. Draw a line on the outer edge of the bracket (as shown). Slide the bracket towards the center of cabinet and align the outside edge of the bracket with the marked line, keeping the rear end edge leaning on the wall.
Install the Hood (EZ1 Bracket) NOTE: The following procedure applies to both framed or frameless cabinet installations. 1 ] Run house power cable between service panel and hood location. 2 ] There are 2 pairs of recessed holes on each side of the top of the hood (on rear: A and B, on front C and D on illustration below); these holes allow the range hood to hang on the brackets (previously installed).
7 ] For framed cabinet, secure the hood to the EZ1 brackets using 4 no. 8-18 x 1/2” metal screws (included in parts bag). Insert 2 screws per side, in the slots (as shown in insets on illustration below). 8 ] For frameless cabinet, secure the hood to the cabinet using 4 no. 8 x 5/8” round head wood screws (included in parts bag). Insert 2 screws per side, in the slots (as shown in insets on illustration below).
Standard Installation (without EZ1 Brackets) 1 ] Use the proper diagram below for placement of ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole, only cut the hole for electrical wiring.
Install the Hood (Standard Installation) 1 ] Run house power cable between service panel and hood location. Run the house power cable into the hood through the strain relief previously installed in step 6 on page 10. 2 ] Hang hood from (4) mounting screws previously installed. Slide hood back towards wall until mounting screw heads are engaged in narrow end of keyhole slots in top of hood. Tighten screws securely. Attach power cable to the hood using the strain relief.
Connect the Wiring ! WARNING Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. MOTOR GROUND WIRE GROUND SCREW HOUSE POWER CABLE 1 ] Connect House Power Cable to range hood wiring: BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw.
Install the Light Bulbs Install two shielded Halogen Bulbs (120 V, 50 W max., MR16 or PAR16 with GU10 base), not included. ! WARNING Do not touch lamps during or soon after operation. Burns may occur. In order to prevent the risk of personal injury, only install shielded halogen lamps. Also, never install a cool beam, a dichroic lamp, a lamp not suitable for use in recessed luminaires or identified for use in enclosed fixtures.
120 V AC Ground Neutral Line BK INSTALLATION MANUAL BK 2 1 Motor Switch 2 1 Light Switch WIRING DIAGRAM 21 BK BL BN G/Y BLACK BLUE BROWN BL (High) W BK (High) R (Low) BROWN/WHITE GREEN/YELLOW ORANGE COLOR CODE Y (Low) BN/W G/Y O W W R W Y W RED WHITE YELLOW BK BK 6 5 4 3 2 1 R O BK G/Y W FAN MOTOR BN/W BN
BCSD SERIES KEY NO. 9 * S97020029 S97020030 S97020031 SR680508 S97020534 S97020408 S97020407 SR99420635 S99010430-001 S99030355 S99030356 S99030367 S97020448 S98011637 * S97020292 * S97020465 * * * SV05921 S99527587 S97020470 1 2 3 4 5 6 7 INSTALLATION MANUAL SERVICE PARTS 8 22 PART NO. DESCRIPTION RECIRCULATION COVER PLATE, BLACK (INCLUDING SCREWS) RECIRCULATION COVER PLATE, WHITE (INCLUDING SCREWS) RECIRCULATION COVER PLATE, STAINLESS STEEL (INCL.
BCSD SERIES KEY NO. 9 * S97020029 S97020030 S97020031 S97020471 SR680508 S97020534 S97020408 S97020407 SR99420635 S99010430-002 S99030355 S99030356 S99030357 S99030367 S97020448 S98011637 * S97020292 * S97020466 * * * SV05921 S99527587 S97020470 RECIRCULATION COVER PLATE, BLACK (INCLUDING SCREWS) RECIRCULATION COVER PLATE, WHITE (INCLUDING SCREWS) RECIRCULATION COVER PLATE, STAINLESS STEEL (INCL.
BCSD SERIES KEY NO. 9 * S97020029 S97020030 S97020031 S97020471 SR680508 S97020534 S97020408 S97020407 SR99420635 S99010430-003 S99030355 S99030356 S99030357 S99030367 S97020448 S98011637 * S97020292 * S97020467 * * * SV05921 S99527587 S97020470 RECIRCULATION COVER PLATE, BLACK (INCLUDING SCREWS) RECIRCULATION COVER PLATE, WHITE (INCLUDING SCREWS) RECIRCULATION COVER PLATE, STAINLESS STEEL (INCL.
BCSD SERIES KEY NO. PART NO. S97020292 * S97020468 * * * SV05921 S99527587 S97020470 8 DESCRIPTION RECIRCULATION COVER PLATE, BLACK (INCLUDING SCREWS) RECIRCULATION COVER PLATE, WHITE (INCLUDING SCREWS) RECIRCULATION COVER PLATE, STAINLESS STEEL (INCL.
WARRANTY INSTALLATION MANUAL 26 Limited Warranty Warranty Period and Exclusions: Broan-NuTone LLC (the “Company”) warrants to the original consumer purchaser of its product (“you”) that the product (the “Product”) will be free from material defects in the Product or its workmanship for a period of one (1) year from the date of original purchase (or such longer period as may be required by applicable law).