ATTO Celerity Fibre Channel Host Adapters Installation and Operation Manual Celerity FC-44ES 4-Gb FC quad channel PCIe host adapter Celerity FC-42ES 4-Gb FC dual channel PCIe host adapter Celerity FC-41ES 4-Gb FC single channel PCIe host adapter Celerity FC-41EL 4-Gb FC single channel host adapter Celerity FC-42XS 4-Gb FC dual channel PCI-X host adapter Celerity FC-41XS 4-Gb FC single channel PCI-X host adapter Celerity FC-21PS 2-Gb FC single channel PCI-X host adapter
ATTO Technology, Inc. 155 CrossPoint Parkway Amherst, New York 14068 USA www.attotech.com Tel Fax (716) 691-1999 (716) 691-9353 Sales support: sls@attotech.com Technical support: Monday -- Friday, 8am-8pm EST techsupp@attotech.com © 2007 ATTO Technology, Inc. All rights reserved. All brand or product names are trademarks of their respective holders. No part of this manual may be reproduced in any form or by any means without the express written permission of ATTO Technology, Inc. 9/2007 ..................
Contents 1 ATTO provides Fibre Channel solutions ..........................................1 Celerity FC-44ES Adapter Celerity FC-42ES Adapter Celerity FC-41ES Adapter Celerity FC-41EL Adapter Celerity FC-42XS Adapter Celerity FC-41XS Adapter Celerity FC-21PS Adapter Celerity selection guide 2 Fibre Channel is a key technology for storage ................................9 Glossary 3 Installing and updating drivers .........................................................
1 ATTO provides Fibre Channel solutions The ATTO Celerity Fibre Channel family of storage products provides connectivity, intelligence and scalability. Celerity FC host adapters simplify advanced storage networking needs such as switching, backup and data management. Specifically designed to enhance the functionality of third party fabric hardware and software, Celerity FC products are the industry-leading platform for storage connectivity.
Celerity FC-42ES Adapter The Celerity FC-42ES is a dual-channel host adapter providing port density for Enterprise server and workstation applications. With 4-Gb FC speeds of up to 800 MB/sec. per channel, the FC-42ES supports the most demanding application requirements. Additionally the FC-42ES takes advantage of the latest in host interconnect technology, PCI Express, a serial, high-speed connection that supports aggregate throughput up to 4 GB/sec. (x8 PCIe) full-duplex.
Celerity FC-41ES Adapter The Celerity FC-41ES is a single-channel host adapter providing support for the most demanding application requirements. With 4-Gb FC speeds of up to 800 MB/sec. per channel, the FC-41ES is a cost effective connectivity solution for environments requiring maximum throughput. The FC-41ES also takes advantage of the latest in host interconnect technology: PCI Express, a serial, highspeed connection that supports aggregate throughput up to 2 GB/sec. (x4 PCIe) full-duplex.
Celerity FC-41EL Adapter The Celerity FC-41EL is a single-channel host adapter. With 4-Gb FC speeds of up to 800 MB/sec., the FC-41EL supports the most demanding application requirements. The FC-41EL takes advantage of the latest in host interconnect technology, PCI Express, a serial, highspeed connection that supports aggregate throughout up to 2 GB/sec.full-duplex.
Celerity FC-42XS Adapter The dual-channel Celerity FC-42XS host adapter provides the highest available throughput for Fibre Channel applications while protecting technology investments via backward compatibility with existing infrastructure. With speeds of up to 800 MB/sec. per channel, the FC42XS is capable of supporting the most intensive data applications.
Celerity FC-41XS Adapter The single-channel Celerity FC-41XS provides speeds of up to 800 MB/sec. using full 4-Gigabit Fibre Channel performance while being fully backwardcompatible with existing 2-GB and 1-Gb Fibre Channel infrastructure, protecting existing technology investments. It is capable of supporting the most dataintense applications. Hardware specifications • • • • • • • • • 1 Fibre Channel port 4-Gigabit data transfer rates 800 MB/sec.
Celerity FC-21PS Adapter The Celerity FC-21PS Fibre Channel host adapter provides a single 2-Gb Fibre Channel connection from host devices to the Storage Area Network (SAN) fabric. The FC-21PS supports the leading operating systems, providing a single solution for all connectivity needs.
Celerity selection guide Celerity FC-44ES Celerity FC-42ES Product Features Fibre Channel Ports FC protocol Maximum Transfer Rate (half duplex) Maximum Transfer Rate (fullduplex) Bus Type Bus Characteristics Optical Interface Maximum Cable Length Low Profile form factor ATTO Advanced Data Streaming (ADS) Technology Software RAID support3 Developer's Kit (Target Mode & API) Windows XP, 2000, Server 2003 and Vista support Linux (Red Hat, SUSE) driver Macintosh OS X driver Novell Netware support Solaris sup
2 Fibre Channel is a key technology for storage Fibre Channel is a serial communications technology designed to transfer large amounts of data among a variety of hardware systems over long distances. It is a key technology for applications that require shared, high bandwidth access to storage. Fibre Channel provides a logical, point-to-point, serial channel for the transfer of data between a buffer at a source device and a buffer at a destination device.
Term Definition fabric a Fibre Channel switch of two or more Fibre Channel switches interconnected to physically transmit data between any two N_Ports on the switch or switches FC Fibre Channel F_port a port in the Fibre Channel fabric where a N_port may attach FL_port a port in the Fibre Channel fabric where a NL_port may attach in an arbitrated loop frame an indivisible unit for transfer of information in Fibre Channel frame header the first field in the frame containing the address and other
3 Installing and updating drivers Before installing your Celerity adapter, you must configure your system to recognize and use it by installing drivers for your operating system.
Upgrading an existing Celerity FC driver 1 Log on to Windows as the System Administrator. 2 Insert your Celerity FC Installation Disk and run autorun.bat 3 In Windows Drivers, select your operating system version. 4 Click on Install Driver. Adding a Celerity FC adapter to an existing installation Note Complete this installation procedure before attaching any devices to the adapter. 1 Complete the steps in Updating hardware flash on page 22 to pre-install the driver.
Creating a Celerity FC installation floppy Note You must have a floppy disk with the Celerity FC driver software to install a fresh copy of the Windows OS onto a disk attached to a Celerity FC adapter. 1 Insert the Installation CD into a CD-ROM. The installation starts automatically. Creating a floppy disk from a download 1 Download the latest driver software from the ATTO website, www.attotech.com. 2 The download is a self-extracting executable that expands the driver software package.
14
4 Hardware installation You need a basic understanding of Fibre Channel before installing the Celerity FC host adapter. Please refer to Fibre Channel is a key technology for storage on page 9 for a list of related websites. WWN 0 WWN 1: WWN 2 WWN 3 CAUTION Back up your system data before changing or installing any hardware. System requirements The Celerity FC host adapter package contains the host adapter, the ATTO Utilities CD and a warranty and registration card.
Bracket details Exhibit 4-1 FC-44ES Adapter Exhibit 4-3 FC-41ES low profile, full height adapters Exhibit 4-2 FC-42ES low profile, full height adapters Exhibit 4-4 FC-41EL low profile, full height adapters 16
Exhibit 4-5 FC-42XS low profile, full height adapters Exhibit 4-6 FC-41XS low profile, full height adapters Exhibit 4-7 FC-21PS Adapter 17 ATTO Technology Inc.
Adapter board details Exhibit 4-8 FC-44ES Exhibit 4-9 FC-42ES FC controller SFP LC optical connectors PCIe connector 18
Exhibit 4-10 FC-41ES FC controller SFP LC optical connector PCIe connector Exhibit 4-11 FC-41EL SFP LC optical connector PCIe connector 19 ATTO Technology Inc.
Exhibit 4-12 FC-42XS Exhibit 4-13 FC-41XS 20
Exhibit 4-14 FC-21PS 21 ATTO Technology Inc.
5 Updating hardware flash Your Celerity FC host adapter was flashed before shipment, but the flash memory may need to be updated as new versions become available or if the factory-installed version becomes corrupt. Visit the ATTO website, www.attotech.com, to download the latest drivers and flash bundle. Hardware flash memory may need to be updated as new versions become available or if the factory-installed version becomes corrupt.
6 Troubleshooting This chapter contains solutions for the most common problems you might encounter. If you need additional assistance, please refer to the ATTO Technology website, www.attotech.com, or contact an authorized ATTO Technology representative. General suggestions • Check each cable connection on every device. • Verify all cables are in proper working condition. Loose or broken cables are often the cause of errors or problems.
If the devices connected to the Celerity FC host adapter are not accessible 1 Right-click My Computer. 2 Select Properties. 3 Select the Hardware tab. 4 Select Device Manager. • If the Celerity FC host adapter does not appear under the SCSI and RAID controllers, remove power from the PC, open the case, and check that the Celerity FC adapter is properly seated in the PCI slot. Replace the case and apply power.
Appendix A Standards and compliances The equipment described in this manual generates and uses radio frequency energy. The Technical Specification sheet for a particular Celerity FC host adapter lists certifications for that model. FCC standards: radio and television interference This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
The following apply to the Celerity FC-42XS host adapter only: ii
Appendix B Accessories The following Fibre Channel accessories are available through ATTO Technology and authorized resellers. Contact an ATTO Technology authorized sales representative to order. Optical Cables CBL-FCFI-05x5 m. cable– Duplex 50 Micron Multi-mode FC/Optical CBL-LCSC-0033 m. 50/125 optical cable (LC to SC) CBL-LCSC-01010 m. 50/125 optical cable (LC to SC) A variety of iSCSI, Fibre Channel, SAS and SCSI products are also available from ATTO Technology.
Appendix C SCSI adapter selection guide Ultra 320 SCSI Product Features Max. transfer rate (MB/sec.) Low Voltage Differential Single-ended SCSI Number of SCSI Channels Number of SCSI IDs supported UL5D 640 640 Cable distances (m) 640 • • 2/2 30 0/2 30 2/2 30 1/1 30 • • • • • 12.5 12.5 12.5 12.
Appendix D SAS adapter selection guide ATTO ExpressSAS RAID Adapters Product Features 1 Max.transfer rate (full duplex) R348 R380 4 GB/sec. 4 GB/sec.
Appendix E Safety, warranty, contacts All ATTO host adapter products have been tested to meet applicable safety standards when operated in proper electrical and thermal environments. Safety Please review the specifications for your specific host adapter before installing and operating it in any computer system to ensure compatibility.
ATTO Technology, Inc. responsibility to repair or replace a defective product is the sole and exclusive remedy provided to the customer for breech of this warranty. ATTO Technology, Inc. is not liable for any indirect, special, incidental, or consequential damages irrespective of whether ATTO Technology, Inc. has advance notice of the possibility of such damages. No ATTO Technology, Inc. dealer, agent or employee is authorized to make any modification, extension or addition to this warranty.