Specifications

22
2-1. Water Supply
1) Water Temperature Selection
Water supply algorithm differs according to water temperature selected among 5 levels.
In other temperatures, with the exception of cold water, constant temperature control is executed.
Cold water and hot water operation is carried out in turn according to the target temperature.
2) For Cold, valve operation does not change according to temperature and only the time unit of
cold on for 7sec and off for 9sec is set to supply cold water per each unit of 16sec.
3) How to Insert Bleach
- During Washing
Operation for 12sec after 3-minute washing in Wool, Silk and Quick wash courses
Operation for 12sec after 5-minute washing in Towel course
Operation for 12sec after 9-minute washing in other courses
Water Temp. Target Temp. Target 1 Target 2
Extra Hot 67) 67) 70)
Hot 35) 34) 36)
Warm* 30) 29) 31)
Warm 30) 29) 31)
Cold - - -
2. Composition per Function