AGA TOTAL CONTROL Model No’s: TC3 & TC5 (ROOM VENT OPTION) Installation Guide REMEMBER: when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by AGA. PLEASE READ THESE INSTRUCTIONS BEFORE COMMENCING SITE SURVEY OR INSTALLING THIS APPLIANCE.
CONTENTS SECTION PAGE HEALTH AND SAFETY 3 INSTALLATION REQUIREMENTS 3 DELIVERY REQUIREMENTS 3 APPLIANCE DIMENSIONS - AGA TC3 (ROOM VENT OPTION) 4 APPLIANCE DIMENSIONS - AGA TC5 (ROOM VENT OPTION) 5 CLEARANCES 6 POWER SUPPLY - AGA TC3 (ROOM VENT OPTION) 7 POWER SUPPLY - AGA TC5 (ROOM VENT OPTION) 7 MAINS CABLE ROUTING - AGA TC3 (ROOM VENT OPTION) 8 MAINS CABLE ROUTING - AGA TC5 (ROOM VENT OPTION) 9 HOTCUPBOARD INSTALLATION 10 HANDRAIL CONNECTION - AGA TC3 (ROOM VENT OPTION) 15 WIRING DIAG
HEALTH AND SAFETY Consumer Protection As responsible manufacturers we take care to make sure that our products are designed and constructed to meet the required safety standards when properly installed and used. PLEASE READ THE ACCOMPANYING WARRANTY. Any alteration that is not approved by AGA could invalidate the approval of the appliance, operation of the warranty and could also affect your statutory rights.
APPLIANCE DIMENSIONS - AGA TC3 (ROOM VENT OPTION) RH SIDE VIEW FRONT VIEW LH SIDE VIEW PLAN VIEW mm MINIMUM WALL POSITION MINIMUM WALL POSITION Fig. 1 DESN 516297 A B C D E F G H J K 987 945 910 680 1385 760 1145 698 116 10 Cooker Dimensions When surveying for a cooker installation the actual clearance required for the ‘body’ of the appliance should be increased by 10mm beyond the figures quote above.
APPLIANCE DIMENSIONS - AGA TC5 (ROOM VENT OPTION) Fig. 2 DESN 516561 A B mm 1478 945 C 910 D E F 680 1385 760 G H J K L 1145 698 116 10 634 Cooker Dimensions When surveying for a cooker installation the actual clearance required for the ‘body’ of the appliance should be increased by 10mm beyond the figures quote above. This allows safe margin to take into account the natural dimensional variations found in major castings.
CLEARANCES The complete cooker is floor-mounted and the space in which the appliance is to be fitted must have the following minimum dimensions:A minimum clearance of 60mm is required above the raised insulating cover handle. Side Clearances:- A 3mm gap is required each side between the cooker top plate and adjoining work surfaces that may be fitted, this is to allow for the safe removal of the top plate should this be required at a later date.
POWER SUPPLY - AGA TC3/TC5 (ROOM VENT OPTION) WARNING: THIS APPLIANCE MUST BE EARTHED. THIS APPLIANCE IS DESIGNED FOR THE VOLTAGE STATED ON THE RATING PLATE, WHICH IS SITUATED BEHIND THE PLINTH COVER. A 1PH 32 amp 230V or 3PH 400V minimum 16A per phase ~ 50 Hz fused electrical supply is required adjacent to the appliance. External wiring to the unit must be installed using the mains cable provided, in accordance with the current wiring regulations and any local regulations which apply.
MAINS CABLE ROUTING - AGA TC3 (ROOM VENT OPTION) MAINS CABLE FED FROM CONTROL TRAY LEFT OR RIGHT EXIT THROUGH DUCTING DEPENDENT UPON POSITION OF SUPPLY SOCKET Fig. 3 DESN 516420 THE MAINS SUPPLY CONNECT POINT MUST BE WITHIN THE ZONES SHOWN Fig.
MAINS CABLE ROUTING - AGA TC5 (ROOM VENT OPTION) HOTCUPBOARD POWER SUPPLY MAINS CABLE FED FROM CONTROL TRAY LEFT OR RIGHT EXIT THROUGH DUCTING DEPENDENT UPON POSITION OF SUPPLY SOCKET Fig. 4 DESN 516562 THE MAINS SUPPLY CONNECT POINT MUST BE WITHIN THE ZONES SHOWN Fig.
HOTCUPBOARD INSTALLATION NOTE: The AGA TC5 hotcupboard should arrive with the top plate in a jacked up position. This is to allow the complete appliance to be slid onto its plinth when alongside the AGA TC3 without the top plates clashing. The hotcupboard top plate should then be wound down to its correct height once the appliance is in its final position. 1. Detach hotcupboard from plinth by removing two screws and tongue bracket from plinth (See Fig.
2. Position the plinth alongside the AGA Total Control leaving no gap between the two plinths (See Fig. 7). Check with a spirit level that the plinth level is correct, and also check height differential between the hotcupboard plinth and Total Control plinth is correct (11mm). If necessary, use shims in each corner to level the plinth. HOTCUPBOARD PLINTH BASE +1 11mm - 0 HEIGHT DIFFERENTIAL Fig. 7 DESN 516564 3.
4. Run a straight edge along the front of the AGA Total Control plinth, to ensure the front face of both plinths sit squarely against the straight edge. (See Fig. 9) When satisfied both plinths sit squarely, jacking screws can be tightened until they just make contact with the AGA Total Control plinth, and locking screws can now be tightened. Fig. 9 USE STRAIGHT EDGE ACROSS BOTH PLINTHS TO ENSURE PLINTHS ARE ALIGNED SQUARELY DESN 516551 5.
6. Slide hotcupboard onto plinth until rear tongue bracket engages fully into rear of base slot, (See Fig. 11). Ensure the appliance is aligned squarely with the plinth then proceed to engage the front tongue bracket into the slot on the underside of the base plate. Once satisfied that the front tongue bracket is engaged fully lock it into place by tightening the two M6 screws fully. Fig. 11 DESN 516552 7. The hotcupboard top plate is set 5mm higher than the AGA Total Control top plate.
8. Using the stay rod nut adjusting tool, carefully lower the top plate adjusting nuts until the top plate sits at the required height, making sure that the top sits level and matches the height of the AGA TC3. (See Fig. 13). For servicing requirement, top plate should be removed by raising adjusters approximately 5mm, the top plate can now be removed easily without causing damage to the enamelled surfaces.
Fig. 14 DESN 516569 HANDRAIL CONNECTION - AGA TC3 Fig. 15 DESN 516560 Handrail brackets, endcaps and handrail require assembly. Locate endcaps onto handrail, place brackets over endcaps and then slide complete assembly onto locating studs. Once assembly is correctly located, lock into position with grub screws (located on underside of handrail).
WIRING DIAGRAM - AGA TC3 (ROOM VENT OPTION) Fig.
WIRING DIAGRAM - AGA TC5 (HOTCUPBOARD OPTION) COLOUR KEYS CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION, WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING Fig.
AGA TOTAL CONTROL POST INSTALLATION CHECKLIST SERIAL No. Tick Box l Check hotplate lids settings. l Check oven door seals, adjust door alignment if necessary. Baking and Simmering Oven rope seals MUST have a gap between the door hinges. The Roasting Oven is fitted with a continuous seal. Ensure any plastic film is removed from the inside of the oven doors. l Ensure Roasting Oven roof baffle is fitted in the correct position.
For further advice or information contact your local AGA Specialist With AGA Rangemaster’s policy of continuous product improvement, the Company reserves the right to change specifications and make modifications to the appliance described and illustrated at any time Manufactured by AGA Rangemaster Station Road Ketley Telford Shropshire TF1 5AQ England www.agaliving.com www.agacookshop.co.