Intruder alarm system Engineering Information 0 Power Power 1 ZONE 1 ZONE 2 0 ZONE 3 1 2 3 2 3 4 5 6 7 1 2 3 4 PA 8 Attack 5 Tamper Chime Day 6 7 8 9 Omit Reset Prog Set 4 ZONE 4 PA ZONE 5 ZONE 6 5 6 7 8 9 Chime Omit Reset Prog Set ZONE 7 ZONE 8 Tamper Attack Day Accenta Power 8SP 401 Accenta G3 panel with remote LED keypad 8EP 395 Optima G3 panel with built-in keypad 1 2 3 4 5 6 7 8 Power 0 1 2 5 6 7 8 9 Reset Prog 3 4 Set PA Attack Tamper P
Engineering information Accenta/Optima G3 Intruder system Features Contents 8z RKP 4 MEM 8 ÿ Features ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ 2 PART SET REMOTE 6 OUTPUT 5 09 SET 8 zones, all programmable for Security, Fire, 24H Fire, PTS or keyswitch applications PA input Tamper input Outputs for Bell and Strobe 4 Access level Codes, User 1, User 2, Engineer and Duress, all programmable 3 fully selectable part set programs Chime on any zone 8 event memory Programmable timers including bell cu
Accenta/Optima G3 intruder system Installation Design Engineering information bell/sounders, strobes and detectors to ensure that this rating is not exceeded. The purchase of this alarm system represents a major step forward in the protection of the property and its occupants. It is important to plan the installation before proceeding and the follow the procedures and advice contained in this manual.
Engineering information Accenta/Optima G3 Intruder system Mounting holes Cable entry holes Note: When replacing the PCB align it on the round support pillars to the bottom and allow it to click down past the clips at the top of the case. Refit the transformer wires into the terminal. Mounting holes Board There are four fuses mounted on the circuit Fit the panel to the wall with suitable fixings. Ensure the wall surface is flat to board, all are 20mm quick blow. F1 1.
Accenta/Optima G3 intruder system Engineering information A combination of up to four remote keypads and lighting controller can be connected to the panel. Wiring the system Caution: Always power-down the panel when wiring external circuits, to prevent damage to the panel electronics. Security zones Panel Systematically wire and test each circuits.
Engineering information Accenta/Optima G3 Intruder system Push to set zone would have to be momentarily turned to its Set position then returned to its Unset position. Any zone can be wired and configured as a Push to Set input. This can be a standard door bell push located outside the premises After starting the exit timer the building is vacated. As the switch is then momentaraily closed, a chime tone is produced and the system Sets.
Accenta/Optima G3 intruder system Panel Board J2 1 2 4 3 5 6 7 PA + 8 TAMP +13V 0V - Engineering information A control marked VOLUME in the centre of the PCB may be used to adjust the low volume entry/exit tones to suit environmental conditions. To adjust this control, partially lift up the top cover. Bell Output (External sounder) The bell is usually installed in a high position from where the bell could be seen and heard. Terminal T A D B are for connection to the external bell or sounder.
Engineering information Accenta/Optima G3 Intruder system A are then used for tamper protection for the sounder housing. Remote signalling Input and Outputs These outputs are not applicable to the Optima compact G3 panel. Panel J6 + - STROBE T A D B BELL SCB + SET BELL/STROBE Board F5 1A - These terminals have been provided for connection to remote signalling equipment such as a digital communicator, Red Care STU or speech dialler.
These outputs would normally be connected directly to the input channels of wire in type communicators and STUs. Alternatively each output can be used to drive a relay(coil resistance > 1200 W ) connected between the output terminal and the 13V supply terminal. The relay will energise when the output port operates. It is recommended that a back EMF protection diode is used in parallel with the relay coil. FIRE The fire output operates when the fire zone is triggered. Engineering information c.
Engineering information Accenta/Optima G3 Intruder system Factory set condition Factory set condition User code 1 - User code 2 - Duress Code - Engineer Code Bell Duration Bell Delay - - - - - - - - 0123 Not programmed Not programmed 9999 20 minutes No delay Program 1 Zone 1 - - Zone 2 - - Zones 3…8 Exit time- Entry - - Exit mode - - - - - - - Timed Time Inhibited Immediate 30seconds 30seconds timed Program 2 Zone1 - - Zone 2 - - Zone 3…8 Exit time- Entry time Exit mode - - - - - -
Accenta/Optima G3 intruder system Engineering information First Power up Note: The G3 range of panels are not supplied with wire links for unused zones. All unused zones must be programmed out by setting them to disabled using the Zone Type function see page 19. Before power up for Optima compact only - fit the top cover on to the base and connect the speaker wires. Leave the cover in position throughout the reset of the installation. b.
Engineering information Accenta/Optima G3 Intruder system Testing the system System indications Complete the wiring of the system and then: ÿ fully test the system and ensure it is fault free. ÿ ÿ ÿ Power Power - Unset system indication - Set system indication Fully program the system Fill in the installation log at the back of the manual and retain if for future reference. To enter Engineer program mode Finally explain the operation of the system to the end user.
Accenta/Optima G3 intruder system Access Codes There are four codes used in the system, all are 4 digit and can be set to any number from 0000 to 9999. The access codes ensure that only authorised users can operate the system. User 1 and 2 codes The user 1 and user 2 codes have the same operation for testing, Setting and Unsetting, but user 1 code which is usually considered to be the Managers code has the authority to add, change or delete the user 2 code and duress code.
Engineering information Accenta/Optima G3 Intruder system Programs Exit Modes program The panel uses 3 Part Set routines known as Programs. In each Program the exit mode can be changed and the zone may be set up to have a different function. Timed A timed Program will become Set as the Exit timer expires. The examples below show how 3 typical Programs could be used in a house. ÿ Program 1 : To arm all of the zones and become Set as the user leaves the property and closes the final door.
Accenta/Optima G3 intruder system Engineering information Programs 1,2 and 3 Example: To configure Program 1 Exit mode to Final door set, Press: Prog 9 9 9 9 Prog 1 6 3 Reset Reset Reset Reset Enter Engineer program mode Prog Set up program Attack 0 Deselect all zones 1 Zone 1 2 Zone 2 3 Zone 3 4 Zone 4 5 Zone 5 6 Zone 6 7 Zone 7 8 Zone 8 Program 1 2 Program 2 Zone 2 3 Program 3 Zone 3 Factory defaults 1 Used Zones All Zones Day 2 Timed Zones Zone 1 Day 3 Time inhibit
Engineering information Accenta/Optima G3 Intruder system Alarm and Walk tests Example: To start bell test and thereafter to stop bell test.
Accenta/Optima G3 intruder system Communicator tests ‘Flag A’ Options Note: These tests are not applicable to Optima compact G3 panel. Example: To test intruder output and thereafter stop the test.
Engineering information Accenta/Optima G3 Intruder system ‘Flag B’ options Viewing the event log Note: The following settings: Communicator output, Line Fail, Program 1, 2 and 3 to report are not applicable to Optima compact G3 panel.
Accenta/Optima G3 intruder system Engineering information Zone Type The G3 range of panels are not supplied with wire links to terminate unused zones. Therefore all unused zones must be programmed out by setting them to disabled using the Zone Type function.
Engineering information Accenta/Optima G3 Intruder system Zone Attributes Example: To configure zones 4 and 5 for ‘Double knock’ operation, Press: Prog 9 9 9 9 6 1 4 5 Reset Reset Reset Enter Engineer program mode Zone 6 Attributes Attack 1 Double Knock 2 Omit Prevent 3 Zone Delay ZONE 1 - 8 Momentarily On Press number button to select / deselect zone delay, Omit zone or Double knock Zone Attributes Day 0 Deselect all zones 1 Zone 1 2 Zone 2 3 Zone 3 4 Zone 4 5 Zone 5 6 Zone 6 7
Accenta/Optima G3 intruder system Engineering information Bell and Service Timers Example: To set bell timer for 10 minutes duration, Press: Prog 9 9 9 9 7 1 1 0 Reset Reset Enter Engineer program mode Timers and 7 Counters Attack Zone 1 1 0 0 Continous operation 0 1 1 minute bell duration 0 2 2 minute bell duration 0 3 3 minute bell duration 2 0 20 minute bell duration (factory default) 9 9 99 minute bell duration Zone 2 Bell timer 2 Bell delay timer 3 Service timer 4 Re-arm co
Engineering information Accenta/Optima G3 Intruder system Re-arm and Anticode reset code Example: To set panel re-arms to 10 times before panel is shut down, Press: 9 Prog 9 9 9 7 4 1 0 Reset Re-arm After an alarm the panel will automatically reset itself when the bell timer has expired. Any zones which still remain open at that time will be omitted automatically.
Accenta/Optima G3 intruder system Engineering information Lighting controller Example: To assign zones 1 and 2 to lighting controller channel 1, Press: Prog 9 9 9 9 9 1 1 2 Reset Reset Reset Enter Engineer program mode Lighting 9 Controller To assign zones to channel press to select and again to deselect zone (Factory default: No zones are selected) Press a number button to select the appropriate light channel All Zones Channel 1 1 assigned zones 1 Channel 2 2 assigned zones 2 Channel 3 3 assigned
Engineering information Accenta/Optima G3 Intruder system Faults g. Before testing or replacing any fuses, ALL power must be removed. Fuses which fail continually are almost certainly the result of a short circuit or low resistance across the 13V supply or external bell supply (terminal D). Fault conditions are often the result of minor installation errors or misinterpretation of the equipment being installed. The following points outline the most common installation and commissioning faults. a.
j. Where Pressure mats are being used these must be connected to a zone in the manner shown. The example below shows pressure mats connected to zones 3.
Engineering information F Index ! 13V Supply . . . 8 24 hour fire zone . 2,6,10,19 3 Part Set . . . . 14 A AC terminals . . Access Codes. . Alarm test . . . Anti Code Reset ARC . . . . . . . . . . . 3 13 16 10,17,22 9 Specification Battery . . . . . . Bell Delay . . . . Bell Duration . . Bell in fire . . . . Bell Output . . . . Bell timer. . . . . Board . . . . . . . BS 4737 1986/87 . 11,25 10 10 17 7,25 21 4 1 C Charge Voltage. . 25 Chime . . . . . . 2 Codes . . . . . . . 2 Communicator . .
Engineering information Servicing organisation Details Parts Servicing organisation name: Below is a list of approved parts and accessories.
1 28 Strobe test The panels conform to the requirements of the European EMC and Low Voltage directives, and carries the CE mark Walk test 6 3 Channel 3 3 assigned zones Channel 4 4 assigned zones Change User code 2 Change Duress code Change Engineer’s code 2 3 9 Set the light threshold level (0 - 99%) Channel 9 Hold time (0-99s) 9 Prog Channel 8 assigned zones 8 Channel 7 7 assigned zones Channel 6 6 assigned zones Channel 5 assigned zones 2 Channel 2 2 assigned zones 5 1 Channel
Intruder alarm system Operating Instructions 8EP 396 Optima compact G3 panel with built-in keypad ZONE 1 ZONE 2 0 ZONE 3 1 2 3 4 ZONE 4 PA ZONE 5 ZONE 6 5 6 7 8 9 Chime Omit Reset Prog Set 1 2 3 4 5 6 7 8 Power ZONE 7 0 1 2 3 4 PA ZONE 8 Tamper Attack Attack Day These operating instructions cover the following intruder system: 5 6 7 8 9 Chime Omit Reset Prog Set Tamper Accenta Power Day ÿ ÿ Accenta /! mini ZONE 1 ZONE 2 ZONE 3 0 1 2 3 4 5 6 7 8 9 C
Operating instructions Accenta/Optima G3 Intruder system How to unset system in alarm Access codes Contents Unset system indications - - - - - - - - - - Set System indication - - - - - - - - - - - Access codes - - - - - - - - - - - - - - - How to operate Personal Attack - - - - - How to unset system in alarm - - - - - - Programs 1, 2 and 3 - - - - - - - - - - - - How to set the system (on program 1) - - Push to Set Switch - - - - - - - - - - - - - Keyswitch Set - - - - - - - - - - - - - - - Faults durin
Accenta/Optima G3 intruder system Operating instructions How to set the system (on program 1) How to unset the system (turn off) The green Day indicator should be showing. Day Enter your code number and check n n n n that the system is clear (none of the 10seconds Exit beep insistent beeps zone indicators are showing). The Day sounder will now produce an exit o/p ARC beep tone and you Set output should leave by the approved route. The system will Set as the beep tone stops.
Operating instructions Accenta/Optima G3 Intruder system How to Quick set How to set Chime Zones During the exit period (on entering User code) Day the system may be Set Set the system or quickly by pressing Set. This removes the exit time Set a Program period. Example: To set zone 3 and 4 to chime, Press: 3 Chime Day If you omit zones and require Quick Set, you will need to press Set twice.
Accenta/Optima G3 intruder system Operating instructions Operator’s Program mode How to view the event log The information below shows the programmable options available and how to change them. The panel can hold up to 8 previous events which can be scrolled automatically or manually. The automatic scroll starts with the newest event ( number 8) to the oldest one ( number 1). Note: When programming the system should be in the Day mode, with the Day and Power indicators lit.
Operating instructions Accenta/Optima G3 Intruder system How to create/omit User 2 code How to create/change/omit the Duress code User 1 code which is usually considered to be Example: To create user 2 the Managers code 4567, Press: code has the Prog 0 1 2 3 7 authority to add, change or delete 4 5 6 7 Reset the user 2 code. Enter Operator’s program mode Change / omit User code 2 7 (By user 1 only) The Duress code is used in a hold up situation where there is pressure to Set or Unset the system.
Accenta/Optima G3 intruder system Operating instructions How to carry out Alarm and Walk tests Example: To start bell test and thereafter to stop bell test. Prog 0 1 2 3 0 3 0 Reset Reset Enter Operator’s program mode 0 Alarm test Press zero to turn off options 2,3,4 and 5 before selecting a new one Attack The walk test function allows each detector to be checked in order to verify that they are functioning correctly.
8 Day Or Exit beep 2 n 5 Leave program mode Reset n n New code n n 8 Reset n n Day Acknowledge n n n n Leave program mode n Change the code of Current user (either User 1 or User 2) n n Leave program mode n o/p ARC Set output View the event log Reset 5 seconds insistent beeps Day Set Set the system or Set a Program Day View event 1 (oldest event) Reset Reset Resume automatic scroll Leave program mode Stop event scroll / view Chime 8 View event 8 (Newest event) 1