it then the output will be changed to OFF status, vice versa.
2.3.4 Store parameters
If you often use a voltage and current as 24V and 2A or 12V and 2.3A and etc, you just need
to set up the data at the first time and then store the data in the power supply. When you need it,
recall it. 3600 series power supply can store up to 10 sets of parameters.
The parameters include 1) Voltage value; 2) Current value; 3) Maximum voltage; 4) Locked/
unlocked keypad; 5) Maximum power ; 6)Baud rate; 7) Communication address.
The store operation always be done after setting up V-set, I-set etc, the operation is as follows:
For example, set up the voltage=15V, current=2A, Maximum output voltage=18V, keypad
locked, Maximum output power=25W, Baud rate=9600, communication address=05, after done
the setup , users can store all the above setup as a set of data, such as the 01 or 02 etc set data.
Procedure The operation Methods LCD display
Step 1 Press “Store” button ENTER PASSWORD
Step 2 Enter the password ( Or jump to step 4 if the keypad ENTER PASSWORD
is unlocked)
Step 3 Press “Enter” button ( it will return to step 2 if your ENTER PASSWORD
password is wrong for reentering) 1234
Step 4 Enter the set value for store number(from 1 to 10) by SAVE 1
using the number key or rotate the rotary knob to
change the set value number
Step 5 Press “Store” button to confirm the set value, if the SAVE *
number is out of the range from 1 to 10, it will retune to
Step 2 for reenter
It will exit the store operation at any procedure by press ESC button