Instruction Manual

3.12.2 Connection of PureLink
TM
Chlorine Generator Electronics to a
Jandy® AquaLink® RS
The chlorine generator electronics in the PureLink power center and the AquaLink
RS controller require a four
(4) wire connection to communicate. Any outdoor rated four (4) conductor cable, minimum 22 AWG, can be used.
Locate the appropriate screw terminals on the circuit board according to Figure 16a and Figure 16b. Wire the chlorine
generator power interface board
from the red 4-pin terminal bar to the AquaLink
RS red 4-pin terminal bar. See
Figure 16a.
Wire the PureLink power center transformer to the load side of the lter pump relay. See Figure 12 and Figure 13.
Figure 16a. Wiring a PureLink Control System
Network
or
All Button
OneTouch
PureLink
Power Center
Chlorine Generator
Power Interface Board
4321
RED
BLK
YEL
GRN
Red, 4-Pin
Terminal Bar
TM
Figure 16b. Wiring a PDA Control System Network
Transceiver
J-box for PDA
PDA
PureLink
Power Center
4321
RED
BLK
YEL
GRN
Red, 4-Pin
Terminal Bar
3.13 Operation of External Control/ORP Control Board
An external device such as an ORP (Oxidation Reduction Potential) controller supplying 24 Volts AC can be used
to control the output of the chlorinator. The chlorinator control board can be set up in the eld to operate in two (2)
different modes. The mode of operation is determined by the position of a movable jumper J14. See Figure 17 for
location.
POS-1 Wait at least one (1) minute after applying power. See note 1.
With J14 jumper set to POS-1 and no voltage applied to the ORP 24 VAC connector J15, the chlorinator
works normally displaying the production rate of 0% to 100% on the front of the power supply.
When 24 Volts AC is applied to the ORP 24 VAC inputs, chlorine production will be disabled.
The front panel of the power supply will then ash “EC” (external control). Once the 24 Volts AC input is
removed the chlorine generator will return to normal operation. The “EC” will be replaced with the current
production setting of 0% to 100%.