Installation Guide

12
Power Rating & Electrical Connection
ELECTRIC POWER RATING
RANGE SIZE AMPERAGE VAC PLUG
RA24 series ranges 20A
240 VAC NEMA 14-50P (50 AMP plug)
RA30 series ranges 15 A
RA36 series ranges 15 A
RA48 series ranges 30A
RA60 series ranges 40A
A properly grounded and horizontally-mounted NEMA 14-50P electrical outlet should
be installed in the wall behind the range at least 2" (51 mm) above the floor and not more
than 8" (203 mm) from the bottom left side (facing product).
L2 (red)
N (white)
G (green)
L1 (black)
L2 (red)
N (white)
G (green)
L1 (black)
cable from
power supply
Four-Wire Connection
Receptacle
NEMA 14-50R
ELECTRICAL GROUNDING
Our oven is equipped with a four-prong plug for your protection against shock hazard
and should be plugged directly into a properly grounded receptacle. Do not cut or remove
the prong from this plug.
Disconnect electrical power at the circuit breaker box or fuse box
before installing the appliance. Provide appropriate ground for the
appliance. Use copper conductors only. No attempt should be made to
operate the appliance during power failure.
WARNING
INSTALLATION